QUARK-ELEC-LOGO

QUARK-ELEC JS01, J1939 Engine Data Gateway

QUARK-ELEC-JS0- J1939-Engine-Data-Gateway-PRODUCT-IMAGE

Ürün Bilgileri

Özellikler

  • Modeli: JS01
  • Type: J1939 Engine Data Gateway
  • Protocol Conversion: J1939 to NMEA 2000
  • Uyumluluk: Android cihazlar
  • Power Source: NMEA 2000 network

Ürün Kullanım Talimatları

Yapılandırma ve Kurulum:
The JS01 is a plug-and-play device for connecting to an NMEA 2000 network. If you need to view engine data or configure multiple engines, you can use the JS01 Config App on an Android tablet or mobile device.

Bellenim Yükseltmesi:
To benefit from new features and enhanced compatibility, periodically check for firmware updates on the Quark-elec webpage. Use the JS01 Config App for easy firmware upgrades.

ÜZERİNDEVIEW

Bu bir bittiview only. Please familiarize yourself with the manual and the manuals of any connecting devices before installation. It is always recommended that electronic equipment be installed by an experienced installer.

KURULUM

  1. Montaj: Consider the location…
    • Kuru ve sağlam bir yer.
    • Gerekli kablo uzunluğunun doğru olduğundan emin olun. Kablolarınız için delik açıyorsanız, su girişini ve teknenize veya ekipmanınıza zarar gelmesini önlemek için kurulumdan sonra tüm deliklerin etrafını kapatın.
  2. Gücü Bağlayın
    The JS01 is powered by the NMEA 2000 network.
  3. NMEA 2000 is a plug-and-play communications standard, the JS01’s NMEA2000 input does not require additional setup before connecting it to an NMEA 2000 network. To protect the device, please don’t power up NMEA 2000 bus during the installation process.
  4. J1939: J1939 is a set of standards defined by the Society of Automotive Engineers (SAE). J1939 builds on the CAN bus by providing a higher-layer protocol that defines message formats, addressing, and error handling.
    Different equipment may use various types of CAN bus connectors. The JS01 uses Deutsch DT04 -6P and DT06-6S connectors, which are known for their reliability and are widely used in marine inboard engines. These connectors were chosen to ensure secure, robust connections in demanding marine environments. If your engine uses a different connector type, an appropriate adapter will be required.
    DT04-6P ve DT06-6S konnektörleri pin-to-pin bağlantılıdır. Bu tasarım, JS01'in mevcut bir CAN veri yolu sistemine, mevcut bağlantıları bozmadan veya etkilemeden entegre olmasını sağlar.
    JS01 ünitesi üç kablo aracılığıyla bağlanır:
    • Pim 1: CAN Düşük
    • Pim 3: CAN High
    • Pim 4: Zemin
      Hatalı bağlantı yapılmadığından emin olmak için lütfen kablolamanızı iki kez kontrol edin. JS01, NMEA 2000 veri yolundan güç aldığı için 12V'a ihtiyaç duymaz.
DT04-6P DT06-6S
Pim 1 DÜŞÜK OLABİLİR DÜŞÜK OLABİLİR
Pim 2 Yok Yok
Pim 3 YÜKSEK OLABİLİR YÜKSEK OLABİLİR
Pim 4 ZEMİN ZEMİN
Pim 5 Yok Yok
Pim 6 Yok Yok

LED ışık:
The LED status indicator will display a solid light when the device is powered on. It will flash to

CONVERSION LISTS

J1939 TO NMEA 2000 CONVERSION LISTS

  • The JS01 operates in a read-only mode on the J1939 interface, ensuring it does not interfere with existing engine control or status systems. It only reads data from the J1939 network and transmits it to the NMEA 2000 bus. This design guarantees there are no security or safety risks to the existing J1939 system.
  • The following table lists the supported NMEA 2000 PGN’s and the related J1939 SPN/PGNs.
Kaynak:

J1939 SPN/PGN

Tanım Converted:

NMEA2000 PGN

92/61443(EEC2) Mevcut Hızda Motor Yüzdesi Yükü 127489
190/61444(EEC1) Motor Hızı 127488
513/61444(EEC1) Gerçek Motor Yüzde Torku 127489
523/61445(ETC2) İletim Akımı Dişlisi 127493
247/65253(SAAT) Motor Toplam Çalışma Saati 127489
110/65262(ET1) Motor Soğutma Suyu Sıcaklığı 127489
175/65262(ET1) Motor Yağı Sıcaklığı 127489
109/65263(ET1) Motor Soğutma Sıvısı Basıncı 127489
100/65263(EFL_P1) Motor Yağı Basıncı 127489
94/65263(EFL_P1) Motor Yakıt Dağıtım Basıncı 127489/130314
183/65266(LFE) Motor Yakıt Oranı 127489
184/65266(LFE) Motor Anlık Yakıt Ekonomisi 127497
173/65270(IC1) Motor Egzoz Gazı Sıcaklığı 130316
102/65270(IC1) Motor Turbo Şarjı Takviye Basıncı 127488
115/65271(VEP1) Alternatör (Akü) Akımı 127508
167/65271(VEP1) Alternatör Potansiyeli (Hacimtage) 127489
168/65271(VEP1) Pil Potansiyeli (Cilt)tage) 127508
127/65272(TRF1) Şanzıman Yağı Basıncı 127493
177/65272(TRF1) Şanzıman yağı sıcaklığı 127493
96/65276(GG) Yakıt seviyesi 127505

UYGULAMA

  • JS01, NMEA 2000 ağına bağlanmadan önce herhangi bir ilk yapılandırma gerektirmeyen tak ve çalıştır bir cihazdır. Ancak, isterseniz view motor verilerini veya birden fazla motoru desteklemek için örnek numarasını ayarlayın, bir Android tablet veya mobil cihazda JS01 Config Uygulamasını kullanmanız gerekecektir. Yapılandırma aracı ayrıca NMEA 2000 ağına iletilen motor hata ve uyarı mesajlarını filtrelemenize olanak tanır.
  • The latest App can be download from Quark-elec webpage page: https://www.quark-elec.com/downloads/configuration-tools/

ÜRÜN YAZILIMINI YÜKSELT

Uyarı: Bu ürün, navigasyona yardımcı olmak için tasarlanmıştır ve normal navigasyon prosedürlerini ve uygulamalarını artırmak için kullanılmalıdır. Bu ürünü ihtiyatlı kullanmak kullanıcının sorumluluğundadır. Quark-elec, distribütörleri veya bayileri, bu ürünün kullanımından veya bu ürünün kullanılmasından kaynaklanan herhangi bir kaza, kayıp, yaralanma veya hasar için ürün kullanıcısına veya mülküne karşı sorumluluk veya yükümlülük kabul etmez.

Scan here for this Device’s User Manual.
QUARK-ELEC-JS0- J1939-Engine-Data-Gateway-IMAGE (1)

  • Lütfen ambalajınızı geri dönüştürün
  • Tüm ürünler CE, RoHS sertifikalıdır
  • Daha fazla bilgi için www.quark-elec.com

Sıkça Sorulan Sorular

Can the JS01 be used with multiple engines?

Yes, the JS01 supports multiple engines, and you can adjust the instance number using the JS01 Config App.

How can I update the firmware of the JS01?

Firmware updates can be easily done using the JS01 Config App. Check the Quark-elec webpage for the latest firmware download.

Is it necessary to connect a 12V power source to the JS01?

No, the JS01 draws power from the NMEA 2000 bus, so there is no need to connect a separate 12V power source.

Belgeler / Kaynaklar

QUARK-ELEC JS01, J1939 Engine Data Gateway [pdf] Kullanıcı Kılavuzu
JS01, JS01 J1939 Engine Data Gateway, JS01 J1939, Engine Data Gateway, Data Gateway, Gateway

Referanslar

Yorum bırakın