L3Campus Stackable Managed Switch

"

Özellikler

  • Model: Omada Campus Stackable L3 Managed Switch
  • Front Panel: Mode Selection Button, Management Port, LED,
    Console Port USB2.0 Port (Type-C/RJ45), 1G RJ45 Port, 10G SFP+ Slot
    NEDEN OLMUŞ
  • LED Göstergesi:
    • PWR1*: Green On (switch powered by PWR1), Off (PWR2
      disconnected or not working properly)
    • PWR2: Green On (switch powered by PWR1 and PWR2 connected),
      Yellow On** (PWR2 powered), Off (PWR1 disconnected or not working
      düzgün bir şekilde)
    • LED SYS FAN: Green On (all fans work properly), Yellow On (not
      all fans work properly)
    • MGMT: On (device linked to port), Flashing (transmitting or
      receiving data), Off (no device linked to port)
    • MST: On (device linked to port), Flashing (transmitting or
      receiving data), Off (no device linked to port)

Ürün Kullanım Talimatları

Bölüm 2: Kurulum

Yükleme işlemine başlamadan önce, tüm
the necessary tools and follow safety precautions.

  • Paket İçeriği: Check all items mentioned in
    paket.
  • Güvenlik Önlemleri: Talimatları takip edin
    güvenli kurulumu sağlayın.
  • Kurulum Araçları: Gather all tools required
    kurulum için.
  • Ürün Kurulumu: Adım adım izleyin
    instructions provided in the manual for successful
    kurulum.

Bölüm 3: Bağlantı

After installation, connect the switch to the network using
appropriate cables and ports as per your network setup.

Bölüm 4: Yapılandırma

Configure the switch based on your requirements. You can choose
between Standalone Mode or Controller Mode as per your network
ihtiyaçlar.

SSS

Q: What should I do if the LED indications show an error?

A: If the LED indications suggest improper functioning, check
the power sources and connections. Refer to the troubleshooting
Daha fazla yardım için kılavuzdaki bölüme bakın.

"`

İş Ağı Çözümü
Kurulum Kılavuzu
Omada Campus Stackable L3 Managed Switch

Bu Kurulum Kılavuzu hakkında
Bu Kurulum Kılavuzu donanım özelliklerini, kurulum yöntemlerini ve kurulum sırasında dikkat edilmesi gereken noktaları açıklar. Bu Kurulum Kılavuzu aşağıdaki şekilde yapılandırılmıştır: Bölüm 1 Giriş Bu bölüm anahtarın harici bileşenlerini açıklar. Bölüm 2 Kurulum Bu bölüm anahtarın nasıl kurulacağını gösterir. Bölüm 3 Bağlantı Bu bölüm anahtarın fiziksel bağlantısının nasıl yapılacağını gösterir. Bölüm 4 Yapılandırma Bu bölüm anahtarın nasıl yapılandırılacağını gösterir. Ek A Sorun Giderme Ek B Özellikler

Kitle

Bu Kurulum Kılavuzu şunlar içindir:

Ağ Mühendisi

Ağ Yöneticisi

Sözleşmeler
· Bu kılavuzda yer alan bazı modeller ülkenizde veya bölgenizde mevcut olmayabilir. Yerel satış bilgileri için https://www.omadanetworks.com/ adresini ziyaret edin.
· Bölüm 2, Bölüm 3 ve Bölüm 4'teki şekiller yalnızca gösterim amaçlıdır. Anahtarınız, tasvir edilenden farklı görünebilir.
· PoE bütçe hesaplamaları laboratuvar testlerine dayanmaktadır. Gerçek PoE güç bütçesi garanti edilmez ve müşteri sınırlamaları ve çevresel faktörler sonucunda değişecektir.
· Bu kılavuz, özel mesajları vurgulamak için belirli biçimleri kullanır. Aşağıdaki tablo, bu kılavuz boyunca kullanılan bildirim simgelerini listeler.

Dikkatli olmayı hatırlatın. Dikkat, cihazın zarar görmesine neden olabilecek bir potansiyeli belirtir.
Dikkate almayı hatırlatın. Not, ürünün daha iyi kullanılması için faydalı bilgiler içerir.

İlgili belge
Ürünün Kullanıcı Kılavuzu ve CLI Başvuru Kılavuzu, İndirme Merkezi'nde sağlanmaktadır. En son ürün bilgilerini almak için resmi ziyaret edin website: https://support.omadanetworks.com/document/.

İçindekiler
Bölüm 1 Giriş ———————- 01
1.1 Ürün Üzeriview ………………………………………………………..01 1.2 Görünüm……………………………………………………………………..01
Bölüm 2 Kurulum ———————- 12
2.1 Paket İçeriği ………………………………………………………….12 2.2 Güvenlik Önlemleri …………………………………………………………12 2.3 Kurulum Araçları…………………………………………………………..14 2.4 Ürün Kurulumu …………………………………………………..14
Bölüm 3 Bağlantı ———————- 22
3.1 Ethernet Port …………………………………………………………..22 3.2 10G SFP+/25G SFP28/100G QSFP28 Slot ………..22 3.3 Console Port ……………………………………………………………22 3.4 Verify Installation…………………………………………………….23 3.5 Power On ………………………………………………………………….24 3.6 Initialization………………………………………………………………24 3.7 Stack Topology ……………………………………………………….24
Bölüm 4 Yapılandırma ——————– 27
4.1 Yapılandırma Bittiview……………………………………………27 4.2 Bağımsız Mod……………………………………………………………27 4.3 Denetleyici Modu…………………………………………………………28
Ek A Sorun Giderme —————- 32
Ek B Özellikler —————— 33

Omada Campus Stackable L3 Managed Switch

Bölüm 1 Giriş

1.1 Ürün Üzeriview
Kurumsal ve kurumsal müşteriler için tasarlanmıştırampus, Omada Campus Stackable L3 Managed Switch provides wire-speed performance and abundant L2 and L3 management features. It provides a variety of service features and multiple powerful functions with high security. The EIA-standardized framework and smart configuration capacity can provide flexible solutions for a variable scale of networks. Static Routing, RIP, OSPF, BGP, IS-IS, PIM-SM/DM/SSM, and ECMP come with abundant Layer 3 routing protocols that support a scalable network. Physically stacking for builtin redundancy and performance. Redundant power supplies and fans make it an ideal choice for reliable networking architecture. VRRP allows a group of switches to dynamically back up each other. ERPS supports rapid protection and recovery in a ring topology. MACsec, secure boot, ACL, 802.1x and Dynamic ARP Inspection provide robust security strategies. QoS and IGMP snooping/filtering optimize voice and video application. Link aggregation (LACP) increases aggregated bandwidth, optimizing the transport of business critical data. SNMP, RMON, WEB, Netconf and CLI Log-in bring abundant management policies. These switches integrate multiple functions with excellent performance, and is friendly to manage, which can fully meet the need of the users demanding higher networking performance. S6500-24GP4XF/S6500-48GP6XF/S6500-24MPP4Y/S6500-48MPP6Y is also a Power Sourcing Equipment (PSE*). The RJ45 ports that support Power over Ethernet (PoE*) function can automatically detect and supply power to those powered devices (PDs*) complying with IEEE 802.3af, IEEE 802.3at, and IEEE 802.3bt (only for S6500-24MPP4Y/S6500-48MPP6Y). *PSE: a device (switch or hub for instance) that provides power through an Ethernet cable. *PoE: This technology describes a system to transmit electrical power, along with data, to remote devices over standard twisted-pair cable in an Ethernet. *PD: a device powered by a PSE and thus consumes energy. Exampdosyalar, ağ kameralarına, kablosuz LAN erişim noktalarına, IP telefonlarına, ağ hub'larına, gömülü bilgisayarlara vb. güç verilmesini içerir.
1.2 Görünüm
Front Panel (The figure is for demonstration only. It may differ from your actual product. )
The front panel of S6500-24G4XF is shown as the following figure.
Mod Seçim Düğmesi
Yönetim Bağlantı Noktası

NEDEN OLMUŞ

Console Port USB2.0 Port (Type-C/RJ45)

1G RJ45 Bağlantı Noktası

10G SFP+ Slot LED

The front panel of S6500-48G6XF is shown as the following figure.
Mod Seçim Düğmesi
Yönetim Bağlantı Noktası

NEDEN OLMUŞ

Console Port USB2.0 Port (Type-C/RJ45)

1G RJ45 Bağlantı Noktası

10G SFP+ Slot LED

Giriş 01

Omada Campus Stackable L3 Managed Switch

LED Göstergesi

PWR1*

PWR2

Yeşil Açık

Kapalı

Yeşil Açık

Sarı Açık**

Kapalı

Yeşil Açık

Kapalı

Kapalı

Gösterge
Anahtar PWR1 ile çalışıyor. PWR2 bağlantısı kesilmiş veya düzgün çalışmıyor.
Anahtar PWR1 tarafından çalıştırılır. PWR1 ve PWR2 bağlı.*
Anahtar PWR2 ile çalışıyor. PWR1 bağlantısı kesilmiş veya düzgün çalışmıyor.
Anahtar kapalı veya hem PWR1 hem de PWR2 düzgün çalışmıyor.

LED SYS FAN
YÖNETİM
MST
Port 1-24 of S6500-24G4XF/ Port 1-48 of S6500-48G6XF
(When the SPEED LED is on)
Port 1-24 of S6500-24G4XF/ Port 1-48 of S6500-48G6XF
(STK LED'i açıkken)
Port 25-28 of S6500-24G4XF/ Port 49-54 of S6500-48G6XF ***

Gösterge
Yanıp sönüyor: Anahtar düzgün çalışıyor. Açık veya Kapalı: Anahtar düzgün çalışmıyor.
Yeşil Açık: Tüm fanlar düzgün çalışıyor. Sarı Açık: Tüm fanlar düzgün çalışmıyor.
On: A device is linked to the port. Flashing: Transmitting or receiving data. Off: No device is linked to the port.
On: The device functions as the master switch in the stack topology or it works individually. Off: The device functions as the member switch in the stack topology.
Yeşil Açık: 1000 Mbps'de çalışıyor, ancak etkinlik yok. Yeşil Yanıp Sönüyor: 1000 Mbps'de çalışıyor ve veri iletiyor veya alıyor. Sarı Açık: 10Mbps/100 Mbps'de çalışıyor, ancak etkinlik yok. Sarı Yanıp Sönüyor: 10Mbps/100 Mbps'de çalışıyor ve veri iletiyor veya alıyor. Kapalı: İlgili porta hiçbir cihaz bağlı değil.
Açık: Bağlantı noktası numarası, yığın topolojisindeki ünite kimliğini gösterir.
Yeşil Açık: 10 Gbps'de çalışıyor, ancak etkinlik yok. Yeşil Yanıp Sönüyor: 10 Gbps'de çalışıyor ve veri iletiyor veya alıyor. Sarı Açık: 1 Gbps'de çalışıyor, ancak etkinlik yok. Sarı Yanıp Sönüyor: 1 Gbps'de çalışıyor ve veri iletiyor veya alıyor. Kapalı: İlgili porta hiçbir cihaz bağlı değil.

*PWR1 is the primary power supply and it takes priority over PWR2. When the device is powered by PWR1, PWR2 will be working in the backup mode.
**Hem PWR1 hem de PWR2 düzgün çalıştığında ve anahtara PWR1 tarafından güç verildiğinde, PWR10'nin fişi çekildikten sonra PWR20 LED'inin (sarı) sönmesi 2-2 saniye sürer.
***All 10 Gbps SFP+ slots can be used as uplink ports or stacking ports. When used as stacking ports, the slots need to run at the highest speed.

02 Giriş

Omada Campus Stackable L3 Managed Switch The front panel of S6500-24GP4XF is shown as the following figure.

Mod Seçim Düğmesi
Yönetim Bağlantı Noktası
LED Console Port USB2.0 Port (Type-C/RJ45)

1G RJ45 Bağlantı Noktası

10G SFP+ Slot LED

S6500-48GP6XF'nin ön paneli aşağıdaki şekilde gösterilmektedir.

Mod Seçim Düğmesi
Yönetim Bağlantı Noktası
LED Console Port USB2.0 Port (Type-C/RJ45)

1G RJ45 Bağlantı Noktası

10G SFP+ Slot LED

The front panel of S6500-24M4Y is shown as the following figure.

Mod Seçim Düğmesi
Yönetim Bağlantı Noktası
LED Console Port USB2.0 Port (Type-C/RJ45)

2.5G RJ45 Bağlantı Noktası

25G SFP28 Slot LED

The front panel of S6500-24MPP4Y is shown as the following figure.

Mod Seçim Düğmesi
Yönetim Bağlantı Noktası
LED Console Port USB2.0 Port (Type-C/RJ45)

2.5G RJ45 Bağlantı Noktası

25G SFP28 Slot LED

Giriş 03

Omada Campus Stackable L3 Managed Switch The front panel of S6500-48M6Y is shown as the following figure.

Mod Seçim Düğmesi
Yönetim Bağlantı Noktası

LED Console Port USB2.0 Port (Type-C/RJ45)

2.5G RJ45 Bağlantı Noktası

The front panel of S6500-48MPP6Y is shown as the following figure.

25G SFP28 Slot LED

Mod Seçim Düğmesi
Yönetim Bağlantı Noktası
LED Console Port USB2.0 Port (Type-C/RJ45)

2.5G RJ45 Bağlantı Noktası

25G SFP28 Slot LED

LED Indication LED
PWR1* PWR2
SYS FAN PoE MAX
(For S6500-24GP4XF, S6500-48GP6XF, S6500-24MPP4Y, S6500-48MPP6Y)
YÖNETİM
MST

Gösterge
Green On: The power supply works properly. Green Flashing: The power supply module is not plugged in properly or not compatible with the switch. Yellow On: The power supply works properly but the switch is powered by the other power supply.** Yellow Flashing: The power supply module is plugged in properly but there’s is no AC power input; abnormal power supply. Off: No power supply module is inserted.
Yanıp sönüyor: Anahtar düzgün çalışıyor. Açık veya Kapalı: Anahtar düzgün çalışmıyor.
Yeşil Açık: Tüm fanlar düzgün çalışıyor. Sarı Açık: Tüm fanlar düzgün çalışmıyor.
Açık: Kalan PoE gücü 7 W'tır. Yanıp sönüyor: Bu LED 7 dakika boyunca açık kaldıktan sonra kalan PoE gücü 2 W'ı korur. Kapalı: Kalan PoE gücü > 7 W'tır.
On: A device is linked to the port. Flashing: Transmitting or receiving data. Off: No device is linked to the port.
On: The device functions as the master switch in the stack topology or it works individually. Off: The device functions as the member switch in the stack topology.

04 Giriş

Omada Campus Stackable L3 Managed Switch

NEDEN OLMUŞ

Gösterge

Port 1-24 of S6500-24GP4XF/
Port 1-48 of S6500-48GP6XF
(When the SPEED LED is on)

Yeşil Açık: 1000 Mbps'de çalışıyor, ancak etkinlik yok. Yeşil Yanıp Sönüyor: 1000 Mbps'de çalışıyor ve veri iletiyor veya alıyor. Sarı Açık: 10Mbps/100 Mbps'de çalışıyor, ancak etkinlik yok. Sarı Yanıp Sönüyor: 10Mbps/100 Mbps'de çalışıyor ve veri iletiyor veya alıyor. Kapalı: İlgili porta hiçbir cihaz bağlı değil.

Port 1-24 of S6500-24M4Y & S6500-24MPP4Y/
Port 1-48 of S6500-48M6Y & S6500-48MPP6Y
(When the SPEED LED is on)

Green On: Running at 2.5 Gbps, but no activity. Green Flashing: Running at 2.5 Gbps and transmitting or receiving data. Yellow On: Running at 10 Mbps/100 Mbps/1000 Mbps, but no activity. Yellow Flashing: Running at 10 Mbps/100 Mbps/1000 Mbps and transmitting or receiving data. Off: No device is linked to the corresponding port.

Port 1-24 of S6500-24GP4XF, S6500-24M4Y &
S6500-24MPP4Y/
Port 1-48 of S6500-48GP6XF, S6500-48M6Y &
S6500-48MPP6Y
(STK LED'i açıkken)

Açık: Bağlantı noktası numarası, yığın topolojisindeki ünite kimliğini gösterir.

Port 1-24 of S6500-24GP4XF & S6500-24MPP4Y/
Port 1-48 of S6500-48GP6XF & S6500-48MPP6Y
(PoE LED'i açıkken)

Green On: The port is supplying power normally. Green Flashing: The supply power exceeds the correponding port’s maximum power. Yellow On: Overload or short circuit is detected. Off: Not providing PoE power on the port

Port 25-28 of S6500-24GP4XF/ Port 49-54 of S6500-48GP6XF ***

Yeşil Açık: 10 Gbps'de çalışıyor, ancak etkinlik yok. Yeşil Yanıp Sönüyor: 10 Gbps'de çalışıyor ve veri iletiyor veya alıyor. Sarı Açık: 1 Gbps'de çalışıyor, ancak etkinlik yok. Sarı Yanıp Sönüyor: 1 Gbps'de çalışıyor ve veri iletiyor veya alıyor. Kapalı: İlgili porta hiçbir cihaz bağlı değil.

Port 25-28 of S6500-24M4Y & S6500-24MPP4Y/
Port 49-54 of S6500-48M6Y & S6500-48MPP6Y***

Green On: Running at 25 Gbps, but no activity. Green Flashing: Running at 25 Gbps and transmitting or receiving data. Yellow On: Running at 1 Gbps/10 Gbps, but no activity. Yellow Flashing: Running at 1 Gbps/10 Gbps and transmitting or receiving data. Off: No device is linked to the corresponding port.

*By default, S6500-24GP4XF is shipped with a PSM500-AC power supply module, S6500-24M4Y/S650048M6Y is shipped with a PSM550-AC power supply module, and S6500-48GP6XF/S6500-24MPP4Y/ S6500-48MPP6Y is shipped with a PSM900-AC power supply module. One more power supply module needs to be purchased separately.
**By default, both PWR1 and PWR2 will work simultaneously in the load sharing mode. They can also work simultaneously in the redundant power supply mode: for S6500-24GP4XF/S6500-48GP6XF/S650024MPP4Y/S6500-48MPP6Y, you can specify the primary power supply and the backup power supply according to your needs; for S6500-24M4Y/S6500-48M6Y, you can only set PWR1 as the primary power supply and PWR2 as the backup power supply. Generally, the primary power supply takes priority over the backup power supply.
***All 10 Gbps SFP+ slots and 25 Gbps SFP28 slots can be used as uplink ports or stacking ports. When used as stacking ports, the slots need to run at the highest speed.

Giriş 05

Omada Campus Stackable L3 Managed Switch The front panel of S7500-26XF6Y is shown as the following figure.
Yönetim Bağlantı Noktası

NEDEN OLMUŞ

Console Port USB3.0 Port

(RJ45/Type-C)

Mod Seçimi

Düğme

10G SFP+ Slot (Port 1-26)

The front panel of S7500-48XF4C is shown as the following figure.

LED 25G SFP28 Slot (Port 27-32)

Mod Seçim Düğmesi
Yönetim Bağlantı Noktası
LED Console Port USB3.0 Port (Type-C/RJ45)

10G SFP+ Slot (Port 1-48)

The front panel of S7500-24Y4C is shown as the following figure.

100G QSFP28 Slot LED (Port 49-52)

Yönetim Bağlantı Noktası

NEDEN OLMUŞ

USB3.0 Bağlantı Noktası

Konsol Bağlantı Noktası

(RJ45/Type-C)

Mod Seçim Düğmesi

25G SFP28 Yuvası

NEDEN OLMUŞ

(Liman 1-24)

The front panel of S7500-48Y8C is shown as the following figure.

100G QSFP28 Slot (Port 25-28)

LED Mode Selection Button

25G SFP28 Slot (Port 1-48)

06 Giriş

100G QSFP28 Slot (Port 49-56)

Omada Campus Stackable L3 Managed Switch The front panel of S7500-32C is shown as the following figure.

Mod Seçim Düğmesi
Yönetim Portu LED'i
USB3.0 Bağlantı Noktası

Console Port (Type-C/RJ45)

100G QSFP28 Yuvası

NEDEN OLMUŞ

Note: S7500-24Y4C and S7500-48Y8C are designed for installation in Network Telecommunications Facilities (NTFs) where ambient temperature and humidity are controlled.

LED Indication LED
PWR1* PWR2
SİSTE FAN
YÖNETİM
MST
Port 1-26 of S7500-26XF6Y/ Port 1-48 of S7500-48XF4C
(SPD LED'i açıkken)
Port 1-24 of S7500-24Y4C/ Port 1-48 of S7500-48Y8C
(When the SPD/SPEED LED is on)

Gösterge
Green On: The power supply works properly. Green Flashing: The power supply module is not plugged in properly or not compatible with the switch. Yellow On: The power supply works properly but the switch is powered by the other power supply.** Yellow Flashing: The power supply module is plugged in properly but there’s is no AC power input; abnormal power supply. Off: No power supply module is inserted.
Yanıp sönüyor: Anahtar düzgün çalışıyor. Açık veya Kapalı: Anahtar düzgün çalışmıyor.
Yeşil: Tüm fanlar düzgün çalışıyor. Sarı: Tüm fanlar düzgün çalışmıyor.
On: A device is linked to the port. Flashing: Transmitting or receiving data. Off: No device is linked to the port.
Not:
For S7500-48Y8C, this LED lights green at 1 Gbps and orange at sub-1 Gbps.
On: The device functions as the master switch in the stack topology or it works individually. Off: The device functions as the member switch in the stack topology.
Yeşil Açık: 10 Gbps'de çalışıyor, ancak etkinlik yok. Yeşil Yanıp Sönüyor: 10 Gbps'de çalışıyor ve veri iletiyor veya alıyor. Sarı Açık: 1 Gbps'de çalışıyor, ancak etkinlik yok. Sarı Yanıp Sönüyor: 1 Gbps'de çalışıyor ve veri iletiyor veya alıyor. Kapalı: İlgili porta hiçbir cihaz bağlı değil.
Green On: Running at 25 Gbps, but no activity. Green Flashing: Running at 25 Gbps and transmitting or receiving data. Yellow On: Running at 1 Gbps/10 Gbps, but no activity. Yellow Flashing: Running at 1 Gbps/10 Gbps and transmitting or receiving data. Off: No device is linked to the corresponding port.

Giriş 07

Omada Campus Stackable L3 Managed Switch

NEDEN OLMUŞ

Gösterge

Port 27-32 of S7500-26XF6Y ***
(SPD LED'i açıkken)

Green On: Running at 25 Gbps, but no activity. Green Flashing: Running at 25 Gbps and transmitting or receiving data. Yellow On: Running at 1 Gbps/10 Gbps, but no activity. Yellow Flashing: Running at 1 Gbps/10 Gbps and transmitting or receiving data. Off: No device is linked to the corresponding port.

Port 49-52 of S7500-48XF4C/
Port 25-28 of S7500-24Y4C/ Port 49-56 of S7500-48Y8C/ Port 1-32 of S7500-32C***
(When the SPD/SPEED LED is on)

Yeşil Açık: 100 Gbps'de çalışıyor, ancak etkinlik yok. Yeşil Yanıp Sönüyor: 100 Gbps'de çalışıyor ve veri iletiyor veya alıyor. Sarı Açık: 40 Gbps'de çalışıyor, ancak etkinlik yok. Sarı Yanıp Sönüyor: 40 Gbps'de çalışıyor ve veri iletiyor veya alıyor. Kapalı: İlgili porta hiçbir cihaz bağlı değil.
Not:
For S7500-48XF4C/S7500-48Y8C/S7500-32C, the indication above applies only when the 100 Gbps QSFP28 slots work with common cables. When the slots work with 1-to-4 breakout cables, a single slot is split into four 25 Gbps interfaces. In such scenario, the LED will light green only when all four interfaces are working at 25 Gbps (maximum speed), otherwise it will light yellow. When no device is connected to any of the four interfaces, the LED will be off. (The 100 Gbps QSFP28 slots will support 1-to-4 breakout cables in a future software release.)

Port 1-32 of S7500-26XF6Y/
Port 1-48 of S7500-48XF4C/ Port 1-28 of S7500-24Y4C/ Port 1-56 of S7500-48Y8C
(STK LED'i açıkken)

Açık: Bağlantı noktası numarası, yığın topolojisindeki ünite kimliğini gösterir.

*By default, S7500-26XF6Y/S7500-48XF4C/S7500-24Y4C/S7500-48Y8C/S7500-32C is shipped with a PSM550-AC power supply module installed respectively. One more power supply module needs to be purchased separately. **By default, both PWR1 and PWR2 will work simultaneously in the load sharing mode. They can also work simultaneously in the redundant power supply mode with PWR1 as the primary power supply and PWR2 as the backup power supply. Generally, the primary power supply takes priority over the backup power supply. ***All 25 Gbps SFP28 slots of S7500-26XF6Y and 100 Gbps QSFP28 slots of S7500-48XF4C/S7500-24Y4C/ S7500-48Y8C/S7500-32C can be used as uplink ports or stacking ports. When used as stacking ports, the slots need to run at the highest speed.
Port Introduction (The Management Port, Console Ports, and USB Ports of S7500-48Y8C are located on the rear panel.)
Management Port Designed to connnect the device for management through web, CLI or SNMP. Do not connect this port to any outdoor device, as this may induce surge and lightning damage. Console Port Designed to connect with a computer for monitoring and configuring the switch. When the switch has an RJ45 console port and a Type-C console port, console input is active on only one console port at a time. By default, the Type-C connector takes priority over the RJ45 connector, or you can change the priority through the web. Do not connect this port to any outdoor device, as this may induce surge and lightning damage. USB Port Designed to install the USB flash disk for data storage. 1000M RJ45 Port Designed to connect to the device with a bandwidth of 10Mbps, 100 Mbps or 1000 Mbps. For PoE switches, the port can also provide power for PDs.

08 Giriş

Omada Campus Stackable L3 Managed Switch
2.5G RJ45 Port Designed to connect to the device with a bandwidth of 10 Mbps, 100 Mbps, 1000 Mbps or 2.5 Gbps. For PoE switches, the port can also provide power for PDs. 10G SFP+ Slot Designed to install the 10 Gbps/1 Gbps optical module. 25G SFP28 Slot Designed to install the 25 Gbps/10 Gbps/1 Gbps optical module. 100G QSFP28 Slot Designed to install the 100 Gbps/40 Gbps optical module. Port Feature

Örnek

1000M

2.5G 10G SFP+ 25G SFP28 100G QSFP28 Management Console USB

RJ45 Port RJ45 Port Slot

Yuva

Yuva

Liman

Liman Liman

S6500-24G4XF

24

/

4

/

/

S6500-48G6XF

48

/

6

/

/

S6500-24GP4XF

24

/

4

/

/

S6500-48GP6XF

48

/

6

/

/

S6500-24M4Y

/

24

/

4

/

S6500-24MPP4Y

/

24

/

4

/

S6500-48M6Y

/

48

/

6

/

S6500-48MPP6Y

/

48

/

6

/

S7500-26XF6Y

/

/

26

6

/

S7500-48XF4C

/

/

48

/

4

S7500-24Y4C

/

/

/

24

4

S7500-48Y8C

/

/

/

48

8

S7500-32C

/

/

/

/

32

1

2

2

1

2

2

1

2

2

1

2

2

1

2

2

1

2

2

1

2

2

1

2

2

1

2

2

1

2

2

1

2

2

1

2

2

1

2

2

Rear Panel (The figure is for demonstration only. It may differ from your actual product. )
The rear panel of S6500-24G4XF/S6500-48G6XF is shown as the following figure. The figure is for demonstration purposes only. Your switch may differ in appearance from the depicted.

Kensington Security Slot Grounding Terminal Power Socket

Locking Strap Slot

Not: PWR1 birincil güç kaynağıdır ve PWR2'ye göre önceliğe sahiptir.

Giriş 09

Omada Campus Stackable L3 Managed Switch
The rear panel of S6500-24GP4XF/S6500-48GP6XF/S6500-24MPP4Y/S6500-48MPP6Y is shown as the following figure. The figure is for demonstration purposes only. Your switch may differ in appearance from the depicted.

Kensington Güvenlik Yuvası

NEDEN OLMUŞ

Topraklama Terminali

Güç Kaynağı Modülü

NEDEN OLMUŞ

Locking Strap Slot

Note: By default, S6500-24GP4XF is shipped with a PSM500-AC power supply module, and S650048GP6XF/S6500-24MPP4Y/S6500-48MPP6Y is shipped with a PSM900-AC power supply module. One more power supply module needs to be purchased separately. Both PWR 1 and PWR2 can work simultaneously, or you can specify the primary power supply and the backup power supply according to your needs. Generally, the primary power supply takes priority over the backup power supply.
The rear panel of S6500-24M4Y/S6500-48M6Y/S7500-26XF6Y/S7500-48XF4C/S7500-24Y4C is shown as the following figure. The figure is for demonstration purposes only. Your switch may differ in appearance from the depicted.

Topraklama Terminali

NEDEN OLMUŞ

Power Supply Module Locking Strap Slot

NEDEN OLMUŞ

Kensington Güvenlik Yuvası

Note: By default, the device is shipped with a PSM550-AC power supply module installed. One more power supply module needs to be purchased separately. When the switch has two power supply modules installed, both PWR1 and PWR2 will work simultaneously in the load sharing mode by default. They can also work simultaneously in the redundant power supply mode: for S6500-24M4Y/S6500-48M6Y, you can only set PWR1 as the primary power supply and PWR2 as the backup power supply; for S7500-26XF6Y/S7500-48XF4C/S7500-24Y4C, you can specify the primary power supply and the backup power supply according to your needs; Generally, the primary power supply takes priority over the backup power supply.

S7500-48Y8C'nin arka paneli aşağıdaki şekilde gösterilmiştir. Şekil yalnızca tanıtım amaçlıdır. Anahtarınızın görünümü gösterilenden farklı olabilir.

Topraklama Terminali

NEDEN OLMUŞ

NEDEN OLMUŞ

Kilitleme Kayışı

Yuva

Güç Kaynağı Modülü

10 Giriş

ManagemeC(nTtoyPnposeor-tCle/RPJoU4rt5S)B3P.o0wPeorrSt upplyLoMcokdiSnulgoletStraLpED

Omada Campus Stackable L3 Managed Switch
Note: By default, the device is shipped with a PSM550-AC power supply module installed. One more power supply module needs to be purchased separately. When the switch has two power supply modules installed, both PWR1 and PWR2 will work simultaneously in the load sharing mode by default. They can also work simultaneously in the redundant power supply mode with PWR1 as the primary power supply and PWR2 as the backup power supply. Generally, the primary power supply takes priority over the backup power supply.
The rear panel of S7500-32C is shown as the following figure. The figure is for demonstration purposes only. Your switch may differ in appearance from the depicted.

LED LED'i
Locking Strap Slot
Power Supply Module Kensington Security Slot

Topraklama Terminali

NEDEN OLMUŞ
Locking Strap Slot

Güç Kaynağı Modülü

Note: By default, the device is shipped with a PSM550-AC power supply module installed. One more power supply module needs to be purchased separately. When the switch has two power supply modules installed, both PWR1 and PWR2 will work simultaneously in the load sharing mode by default. They can also work simultaneously in the redundant power supply mode with PWR1 as the primary power supply and PWR2 as the backup power supply. Generally, the primary power supply takes priority over the backup power supply.
Power Supply Module The pluggable power supply module PSM500-AC/PSM900-AC/PSM550-AC is an AC-input power supply module. It can convert the input voltage to 53.5 V (12 V for PSM550-AC) with the maximum output power of 500 W/900 W/550 W respectively. Kensington Security Slot Secure the lock (not provided) into the security slot to prevent the device from being stolen.
Grounding Terminal The switch already comes with lightning protection mechanism. You can also ground the switch through the PE (Protecting Earth) cable of AC cord or with Ground Cable. For detailed lightning protection measures, refer to the Lightning Protection Guide from: https://support.omadanetworks.com/r/1004/. Locking Strap Slot Remove the instruction label and insert the AC power cable locking strap into the slot to secure the power cable.

Giriş 11

Omada Campus Stackable L3 Managed Switch

Bölüm 2 Kurulum

2.1 Paket İçeriği

Paketin aşağıdaki öğeleri içerdiğinden emin olun. Listelenen öğelerden herhangi biri hasarlı veya eksikse, lütfen distribütörünüzle iletişime geçin. Rakamlar sadece gösteri amaçlıdır. Gerçek öğeler, tasvir edilenden görünüm ve miktar olarak farklı olabilir.

Anahtar

Güç Kablosu ve Konsol Kablosu

Kurulum Kılavuzu
İş Ağı Çözümü
Kurulum Kılavuzu
Omada Campus Stackable L3 Managed Switch

Montaj Braketleri, Vidalar ve Lastik Ayaklar

2.2 Güvenlik Önlemleri
Cihazınızın yanlış kullanımı sonucu oluşabilecek hasar ve yaralanmaları önlemek için aşağıdaki kurallara uymalısınız.
Güvenlik Önlemleri Kurulum sırasında gücü kapalı tutun. ESD önleyici bir bilek kayışı takın ve bilek kayışının cilde iyi temas ettiğinden ve sağlam olduğundan emin olun.
İyi topraklanmış. Sadece anahtarla birlikte verilen güç kablosunu kullanın. Besleme voltajının doğru olduğundan emin olun.tage, arka panelde belirtilen özelliklere uymaktadır
Anahtarın iyi havalandırılan bir ortama monte edildiğinden ve havalandırma deliğinin kapalı olmadığından emin olun.
engellendi. Anahtarın kapağını açmayın veya çıkarmayın. Cihazı temizlemeden önce güç kaynağını kesin. Sulu bezle temizlemeyin ve asla
use any other liquid cleaning method. Place the device with its bottom surface facing downwards. Only instructed person or skilled person can be allowed to install, replace, or service this device.
Site Gereksinimleri
Sıcaklık/Nem

12 Kurulum

Omada Campus Stackable L3 Managed Switch Keep the equipment room at an appropriate level of temperature and humidity. Too much or too little humidity may lead to bad insulation, leakage of electricity, mechanical property changes, and corrosion. High temperatures may accelerate aging of the insulation materials, significantly shortening the service life of the device. To find out the best temperature and humidity conditions for the device, check the Appendix B Specifications. Clearness
Anahtarda biriken toz statik elektrik tarafından emilebilir ve metal temas noktalarının zayıf temasına neden olabilir. Cihazda statik elektriği önlemek için bazı önlemler alınmıştır, ancak çok güçlü statik elektrik dahili devre kartındaki elektronik elemanlara ölümcül hasar verebilir. Statik elektriğin anahtarın çalışması üzerindeki etkisini önlemek için aşağıdaki maddelere çok önem verin: Cihazı düzenli olarak tozdan arındırın ve iç mekan havasını temiz tutun. Cihazı iyi topraklanmış tutun ve statik elektriğin aktarıldığından emin olun. Elektromanyetik Girişim
Cihazdaki kapasitans ve endüktans gibi elektronik elemanlar, kapasitans kuplajı, endüktans kuplajı ve empedans kuplajı gibi dış parazitlerden etkilenebilir. Parazitleri azaltmak için aşağıdaki önlemleri aldığınızdan emin olun: Elektrik şebekesinden gelen paraziti etkili bir şekilde filtreleyebilen güç kaynağı kullanın. Cihazı radyo iletimi gibi yüksek frekanslı ve güçlü akım cihazlarından uzak tutun
istasyon. Gerektiğinde elektromanyetik kalkan kullanın. Yıldırım Koruması
Kurulum 13

Omada Campus Stackable L3 Managed Switch
Son derece yüksek hacimtagYıldırım oluştuğunda anında akım üretilebilmekte ve elektrik deşarj yolundaki hava anında 20,000 °C'ye kadar ısıtılabilmektedir. Bu anlık akım elektronik cihazlara zarar verebilecek kadar güçlü olduğundan daha etkili yıldırımdan korunma önlemleri alınmalıdır. Rafın ve cihazın iyi bir şekilde topraklandığından emin olun. Elektrik prizinin toprakla iyi temas ettiğinden emin olun. Makul bir kablolama sistemi bulundurun ve yıldırım düşmesini önleyin. Dış mekanda kablolama yaparken SPD (Aşırı Gerilim Koruma Cihazı) sinyalini kullanın.
Not: Ayrıntılı yıldırımdan korunma önlemleri için şu adresteki Yıldırımdan Korunma Kılavuzuna bakın: https://support.omadanetworks.com/r/1004/. Kurulum Alanı
When installing the device on a rack or a flat workbench, attach much importance to the following items: Install the device with its bottom surface facing down only. This equipment is not suitable for use in locations where children are likely to be present. The rack or workbench is flat, stable, and sturdy enough to support the weight of 9.5 kg at least. The rack or workbench has a good ventilation system. The equipment room is well ventilated. The rack is well grounded. Keep the device less than 1.5 meters away from the power socket.
2.3 Kurulum Araçları
Phillips tornavida ESD önleyici bilek sargısı Kablolar
Not: Bu aletler ürünümüze dahil değildir. İhtiyaç halinde bunları ayrı olarak satın alabilirsiniz.
2.4 Ürün Kurulumu
Anahtar, önden arkaya ısı dağıtma özelliğiyle tasarlanmıştır. Çalıştığında hava aşağıda gösterildiği gibi dolaşır. Daha iyi ısı dağılımı için lütfen cihazı iyi havalandırılan bir ortama kurun ve cihazın çevresinde 5 ila 10 cm boşluk bırakın.
14 Kurulum

Şekil 2-1

Hava Sirkülasyonu

Omada Campus Stackable L3 Managed Switch

Masaüstü Kurulumu

Cihazı masaüstüne kurmak için şu adımları izleyin:
1. Cihazı, tüm bağlantı parçalarıyla birlikte cihazın tüm ağırlığını taşıyabilecek kadar sağlam, düz bir yüzeye yerleştirin.

2. Yapışkan destek kağıtlarını lastik ayaklardan çıkarın.

3. Cihazınızın masaüstüne yerleştirildiğinde kaymasını önlemek için kauçuk ayakları cihazın altına takın.

Şekil 2-2

Masaüstü Kurulumu

Ayaklar Cihazın Alt Kısmı Çentik

Raf Montajı

Pakette 6 çift farklı raf montaj braketi bulunur; bunların resimleri aşağıda gösterilmektedir ve gerçek ürünlerden farklı olabilir.

Şekil 2-3

Montaj Braketleri

Screw Hole Group 2

Bracket D Bracket C Bracket B Bracket A

Screw Hole Group 1
Screw Hole Group 3

Braket F

Screw Hole Group 4-2 (for device with 420mm depth)

Screw Hole Group 5

Vida deliği

Grup 4-1

Screw Hole Group 4-3

(for device with 380mm depth)

(for device with

460mm depth)

Parantez E

Kurulum 15

Omada Campus Stackable L3 Managed Switch

Before installing the device in an EIA standard-sized, 19-inch rack, please check the efficiency of the grounding system and the stability of the rack, then wear an ESD-preventive wrist strap, and make sure that it has good skin contact and is well grounded. Bracket B, C & E have two adjustable ears, please measure the distance between the front-post rack and the rear-post rack, and determine a suitable mounting method from below:

Yöntem

Gösteri

Front: Bracket A Rear: Bracket D (Screw Hole Group 1) + Bracket B (Ear towards back)

Rack Distance
(For device with a depth of 380mm)

Rack Distance
(For device with a depth of 420mm)

Rack Distance
(For device with a depth of 460mm)

498-640mm 538-680mm 578-720mm

Front: Bracket A Rear: Bracket D (Screw Hole Group 1) + Bracket C (Ear towards back)

477-498mm 517-538mm 557-578mm

Front: Bracket A Rear: Bracket D (Screw Hole Group 2) + Bracket C (Ear towards back)

429-477mm 469-517mm 509-557mm

Front: Bracket A Rear: Bracket D (Screw Hole Group 2) + Bracket C (Ear towards front)

410-429mm 450-469mm 490-509mm

Front: Bracket A Rear: Bracket D (Screw Hole Group 3) + Bracket C (Ear towards back)

357-410mm 397-450mm 437-490mm

Front: Bracket A Rear: Bracket D (Screw Hole Group 2) + Bracket B (Ear towards back)

282-410mm 322-450mm 362-490mm

16 Kurulum

Omada Campus Stackable L3 Managed Switch

Front: Bracket A Rear: Bracket F (Screw Hole Group 4) + Bracket E (Ear towards back)

555-936mm 555-936mm 555-936mm

Front: Bracket A Rear: Bracket F (Screw Hole Group 5) + Bracket E (Ear towards back)

743-1121mm 743-1121mm 743-1121mm

Cihazı kurmak için aşağıda açıklanan talimatları izleyin:

1. Attach the M6 nuts to the racks.

Şekil 2-4

Securing M6 Nuts

×8

2. Attach the mounting brackets (B, C or E) to the rear-post racks and secure them with the provided M6 screws, as illustrated in the following figure.

Şekil 2-5

Installing Brackets on Racks

or

3. Attach the brackets A & D/F to the switch with the provided M3 screws.

Kurulum 17

Omada Campus Stackable L3 Managed Switch

Şekil 2-6

Installing Brackets on Switch

4. After the brackets are attached to the device, hold the switch with attached brackets up until it aligns with the brackets on the racks, and gently push the switch backwards until it is in place, then secure the device on the racks with M6 screws and fix brackets B/C or E to brackets D or F with M4 screws on both sides.

Şekil 2-7

Installing Switch on Racks

Caution: Leave 5 to 10 cm gaps around the devices for air circulation. Avoid placing heavy things on the device. Mount devices in the order demonstrated above and ensure a certain clearance between devices for
the purpose of heat dissipation.

18 Kurulum

Omada Campus Stackable L3 Managed Switch

Güç Kaynağı Modülü Kurulumu

S6500-24GP4XF is shipped with a PSM500-AC power supply module installed, S6500-48GP6XF/ S6500-24MPP4Y/S6500-48MPP6Y is shipped with a PSM900-AC power supply module installed, and S6500-24M4Y/S6500-48M6Y/S7500-26XF6Y/S7500-48XF4C/S7500-24Y4C/S7500-48Y8C/S750032C is shipped with a PSM550-AC power supply module installed. It looks like below, and the image may differ from your actual product.

Şekil 2-8

Appearance of the Power Supply Module

AC Güç Kablosu Konektörü
FAN

Tutucu Klipsler

Extraction Handle

NEDEN OLMUŞ

Locking Strap Slot Release Handle

Bir güç kaynağı modülü daha eklemeniz gerekiyorsa lütfen aşağıdaki adımları izleyin:

1. Wear an ESD-preventive wrist strap, and make sure that it has good skin contact and is well grounded.

2. Press the extraction handle of the module with one hand, and hold the bottom of the module using your other hand. Gently push the module in along the slot guide rail.

3. Release the extraction handle to fix the power supply module in place.

Şekil 2-9

Güç Kaynağı Modülünü Takma

Serbest Bırakma Kolu

Caution: Do not plug the power cord until the power supply module installation is completed. When installing a power supply module, make sure it is set correctly in the operation of installation. Do not use too much force in the installation. If resistance is encountered or positions of the power
supply module appear larger during installation, you must first remove the module and then reinstall the module. If the Retainer Clips cannot spring up naturally and the power module is blocked, it may be due to the power supply module is not installed properly. Please check carefully.
The power supply module is designed with a locking strap slot. If you need to secure the power cable with the included locking strap, please follow the steps:
1. Wear an ESD-preventive wrist strap, and make sure that it has good skin contact and is well grounded.
Kurulum 19

Omada Campus Stackable L3 Managed Switch
2. Remove the instruction label on the AC power cable locking strap slot. 3. Attach the clamp to the AC power cable and insert the locking strap into the slot. 4. Adjust tightness and distance of the locking strap using clips to ensure the cable is securely fastened.
Figure 2-10 Installing the Locking Strap

Güç kaynağı modülünü çıkarmanız gerekiyorsa lütfen aşağıdaki adımları izleyin:
1. Wear an ESD-preventive wrist strap, and make sure that it has good skin contact and is well grounded.
2. Depress the retainer clip to release the locking strap, and then remove the power cord from the external power supply system and the power module.
3. Press the extraction handle of the module with one hand, and pull the extraction handle using your other hand, until the module completely comes out of the chassis.
Caution: Unplug the power cord first, then remove the power supply module. When removing a power supply module, make sure that the power supply module is set correctly in the
operation of installation. In order to better protect the power supply module during removal, it is recommended that you
package it in an antistatic bag.
Fan Modülü Kurulumu
S6500-24GP4XF/S6500-48GP6XF/S6500-24M4Y/S6500-24MPP4Y/S6500-48M6Y/S650048MPP6Y/S7500-26XF6Y/S7500-48XF4C/S7500-24Y4C/S7500-48Y8C/S7500-32C is shipped with hot-swappable fan modules installed. They look like below, and the images may differ from your actual product.
Şekil 2-11 Fan Modülünün Görünümü
NEDEN OLMUŞ

20 Kurulum

Extraction Handle Retainer Clips Release Handle

Omada Campus Stackable L3 Managed Switch For normal operation of the switch, please ensure that models with 5 fan modules maintain at least 4 operational modules, while models with 4 fan modules maintain at least 3 operational modules. If one fan module is damaged, please replace it as follows: 1. Wear an ESD-preventive wrist strap, and make sure that it has good skin contact and is well
grounded. 2. Press the extraction handle of the module with one hand, and pull the extraction handle until the
module completely comes out of the chassis.
Şekil 2-12 Hasarlı Bir Fan Modülünün Çıkarılması
3. Press the extraction handle of a new fan module with one hand, and hold the bottom of the module using your other hand. Gently push the module in along the slot guide rail.
4. Release the extraction handle to fix the power supply module in place. Caution: S6500-24GP4XF/S6500-48GP6XF/S6500-24M4Y/S6500-24MPP4Y/S6500-48M6Y/S6500-48MPP6Y/ S7500-26XF6Y uses hot-swappable fan modules with a maximum speed of 9,000 RPM. S7500-48XF4C/ S7500-24Y4C/S7500-48Y8C/S7500-32C uses hot-swappable fan modules with a maximum speed of 18,000 RPM. Please do not interchange or mix fan modules between models. Sharp edges on the fan module may cause injury, so please operate with caution. Make sure the damaged fan module is in place before you are going to replace it. DO NOT unplug the damaged fan module until the replacement operation. Do not use too much force in the replacement. If resistance is encountered or positions of the fan module appear larger during installation, you must first remove the module and then reinstall the module. If the Retainer Clips cannot spring up naturally and the power module is blocked, it may be due to the fan module is not installed properly. Please check carefully.
Kurulum 21

Omada Campus Stackable L3 Managed Switch

Bölüm 3 Bağlantı

3.1 Ethernet Bağlantı Noktası

Aşağıdaki şekilde gösterildiği gibi anahtarın Ethernet portunu RJ45 kablosu ile bilgisayara bağlayın.

Şekil 3-1

RJ45 Portunu Bağlama

RJ45 Bağlantı Noktası

RJ45 Kablo

3.2 10G SFP+/25G SFP28/100G QSFP28 Slot

The following figure demonstrates the connection of 10G SFP+/25G SFP28/100G QSFP28 slot to an optical module

Şekil 3-2

Inserting the Fiber Module

Slot Fiber Module

3.3 Konsol Bağlantı Noktası
CLI (Komut Satırı Arayüzü), anahtarı yönetmenizi sağlar, böylece PC'leri veya Terminalleri bir kablo aracılığıyla anahtardaki konsol portuna bağladıktan sonra CLI'yi yükleyebilirsiniz (bir RJ45 konsol kablosu sağlanır, ancak Type-C kablosu sağlanmaz)
Cihazın RJ45 konsol portunu aşağıdaki şekilde gösterildiği gibi konsol kablosunu kullanarak bilgisayarınıza bağlayın.

22 Bağlantı

Şekil 3-3

Konsol (RJ45) Bağlantı Noktasını Bağlama

Omada Campus Stackable L3 Managed Switch

Aşağıdaki şekilde gösterildiği gibi, cihazın Type-C konsol bağlantı noktasını Type-C kabloyla (ürünle birlikte verilmez) bilgisayarınıza bağlayın.

Şekil 3-4

Konsol (USB) Bağlantı Noktasını Bağlama

Note: RJ45 console port and Type-C console port cannot be used concurrently. Type-C Console port takes
priority over the RJ45 console port. The Type-C console port is hot-pluggable while the RJ45 console port is not. Keep the device power
off when plugging the console cable into the RJ45 console port. Do not connect the console port with other ports by RJ45 cable.
3.4 Kurulumu Doğrulayın
Kurulumu tamamladıktan sonra aşağıdaki öğeleri doğrulayın: Havalandırma için cihazın etrafında 5 ila 10 cm boşluk olmalı ve hava akışının sağlandığından emin olun.
yeterlidir. CilttagGüç kaynağının e'si giriş hacmi gereksinimini karşılartagCihazın e. Güç soketi, cihaz ve raf iyi topraklanmış. Cihaz diğer ağ cihazlarına doğru şekilde bağlanmış.
Bağlantı 23

Omada Campus Stackable L3 Managed Switch

3.5 Açma

Verilen güç kablosunun dişi konnektörünü cihazın elektrik prizine, pozitif konnektörünü ise aşağıdaki şekilde gösterildiği gibi elektrik prizine takın. vol olduğundan emin oluntagGüç kaynağının e'si giriş hacmi gereksinimini karşılartage (100-240 V~ 50/60 Hz).

Şekil 3-5

Güç Kaynağına Bağlanma

Note: The figure is to illustrate the application and principle. The provided plug and module in your region
may differ from the figures above. Generally PWR1 takes priority over PWR2.

3.6 Başlatma
Cihaz açıldıktan sonra, Açılışta Kendi Kendine Testini başlatır. Cihazın düzgün çalıştığından emin olmak için bir dizi test otomatik olarak çalışır. Bu süre boyunca LED göstergeleri aşağıdaki sırayla yanıt verecektir:
1. PWR LED göstergesi her zaman yanar. Tüm bağlantı noktalarının SYS LED'i ve LED göstergeleri kapalı.
2. Yaklaşık bir dakika sonra SYS LED'i ve tüm portların LED göstergeleri bir an yanıp sönecek ve ardından sönecektir.
3. Birkaç saniye sonra, başarılı bir başlatmayı temsil eden SYS LED göstergesi yanıp sönecektir.
3.7 Yığın Topolojisi
With stackable design, the switches can be stacked into one stack topology for higher reliability, larger bandwidth, and simpler networking. To build the stack topology, you need to prepare 2-12 switches and enough 10G SFP+/25G SFP28/100G QSFP28 modules/cables. For more details, see the table below:

Anahtar

Uyumlu Model(ler)

Miktar

S6500-24G4XF S6500-24G4XF, S6500-48G6XF, S6500-24GP4XF, S6500-48GP6XF S6500-48G6XF S6500-24G4XF, S6500-48G6XF, S6500-24GP4XF, S6500-48GP6XF S6500-24GP4XF S6500-24G4XF, S6500-48G6XF, S6500-24GP4XF, S6500-48GP6XF S6500-48GP6XF S6500-24G4XF, S6500-48G6XF, S6500-24GP4XF, S6500-48GP6XF S6500-24M4Y S6500-24M4Y, S6500-24MPP4Y, S6500-48M6Y, S6500-48MPP6Y S6500-24MPP4Y S6500-24M4Y, S6500-24MPP4Y, S6500-48M6Y, S6500-48MPP6Y

2-12 (max 12 in standalone mode, max 4 in controller mode) 2-12 (max 12 in standalone mode, max 4 in controller mode) 2-12 (max 12 in standalone mode, max 4 in controller mode) 2-12 (max 12 in standalone mode, max 4 in controller mode) 2-12 (max 12 in standalone mode, max 4 in controller mode) 2-12 (max 12 in standalone mode, max 4 in controller mode)

24 Bağlantı

Omada Campus Stackable L3 Managed Switch

S6500-48M6Y S6500-24M4Y, S6500-24MPP4Y, S6500-48M6Y, S6500-48MPP6Y

S6500-48MPP6Y S6500-24M4Y, S6500-24MPP4Y, S6500-48M6Y, S6500-48MPP6Y

S7500-26XF6Y S7500-26XF6Y

S7500-48XF4C S7500-48XF4C

S7500-24Y4C S7500-24Y4C

S7500-48Y8C S7500-48Y8C

S7500-32C

S7500-32C

2-12 (max 12 in standalone mode, max 4 in controller mode) 2-12 (max 12 in standalone mode, max 4 in controller mode) 2-12 (max 12 in standalone mode, max 4 in controller mode) 2-12 (max 12 in standalone mode, max 4 in controller mode) 2-12 (max 12 in standalone mode, max 4 in controller mode) 2-12 (max 12 in standalone mode, max 4 in controller mode) 2-12 (max 12 in standalone mode, max 4 in controller mode)

Farklı senaryolar için üç yığın topolojisi yapısı vardır; lütfen ihtiyaçlarınıza göre uygun topolojiyi oluşturun:

1. Zincir Topolojisi: Zincir topolojisi nispeten basittir ve ilk ve son ünite arasında kablo bağlantısı gerektirmez. Uzun mesafeli istifleme için uygundur, ancak güvenilirliği nispeten düşüktür.

Şekil 3-6

Zincir Topolojisi

Yığınlama Limanı Grup 2
Yığınlama Limanı Grup 1

2. Halka Topolojisi: Halka topolojisi, zincir topolojisine kıyasla daha yüksek güvenilirliğe sahiptir. Halka topolojisindeki zincirlerden biri bağlantısı kesildiğinde, halka topolojisi bir zincir topolojisi haline gelir, ancak tüm yığın sistemi hala normal şekilde çalışabilir. Halka topolojisi, ilk ve son ünite arasında kablo bağlantısı gerektirir, bu nedenle uzun mesafeli yığınlama için uygun değildir.

Şekil 3-7

Halka Topolojisi

Yığınlama Limanı Grup 2

Yığınlama Limanı Grup 1

Bağlantı 25

Omada Campus Stackable L3 Managed Switch

3. Yıldız Topolojisi: Yıldız topolojisi, anahtarları merkezi bir ana anahtara bağlar, bu sayede üye anahtarlar arasındaki veri iletim hızını önemli ölçüde artırabilir ve birleşik yönetim sağlayabilir.

Şekil 3-8

Yıldız topolojisi

Yığınlama Limanı Grup 2

Yığınlama Limanı Grup 3

Yığınlama Limanı Grup 1

Note: The stacking port is not allowed to connect to non-stacking port, as it may affect the operation of the
device. Stacking ports with the same group ID are not allowed to connect to stacking ports with different
group IDs, neither to different devices. A stacking port group is a logical port dedicated to stacking and needs to be bound to a stacking port.
A stacking port group can be bound to one or more stacking ports to improve bandwidth and reliability.

26 Bağlantı

Omada Campus Stackable L3 Managed Switch

Bölüm 4 Yapılandırma

4.1 Yapılandırma Bittiview
Anahtar iki yapılandırma seçeneğini destekler:
Bağımsız Mod: Anahtarı tek tek yapılandırın ve yönetin. Denetleyici Modu: Ağ aygıtlarını merkezi olarak yapılandırın ve yönetin.
Erişim noktaları, anahtarlar ve ağ geçitleri gibi büyük aygıtlardan oluşan büyük ölçekli ağ.
Not: Anahtar Bağımsız Moddan Denetleyici Moduna değiştirildiğinde, anahtarın yapılandırmaları kaybolacaktır. Ayrıntılar için yetkilimizin indirme merkezindeki ilgili belgelere bakın. website: https://support.omadanetworks.com/product/.

4.2 Bağımsız Mod

Bağımsız Modda, anahtarı GUI (Grafik Kullanıcı Arayüzü) veya CLI (komut satırı arayüzü) kullanarak yapılandırmak ve yönetmek için bir bilgisayar kullanın.

Şekil 4-1

Bağımsız Mod için Topoloji

Anahtar

PC

GUI'yi kullanma
1. Anahtarın yönetim sayfasına erişmek için anahtarın ve bilgisayarın aynı alt ağda olduğundan emin olun. Bir tarayıcı açın ve adres alanına anahtarın IP adresini yazın, ardından Enter tuşuna basın.
Eğer anahtar IP adresini DHCP sunucusundan (genellikle bir ağ geçidi) alıyorsa, DHCP sunucusunda anahtarın IP adresini bulun.
Değilse, anahtarın yönetim sayfasını başlatmak için varsayılan IP adresi 192.168.0.1'i kullanın.

2. İlk kez oturum açtığınızda, ağınızı ve cihazlarınızı daha iyi korumak için kullanıcı adınızı ve parolanızı ayarlayın. Ardından, sistem sizi yeni oluşturulan kimlik bilgileriyle kimlik doğrulaması yapmanız için otomatik olarak oturum açma arayüzüne yönlendirecektir.

3. Başarılı bir giriş yaptıktan sonra ana sayfa görünecektir. İlgili işlevleri yapılandırmak için üst ve sol taraftaki menülere tıklayabilirsiniz.
Ayrıntılı yapılandırmalar için Kullanıcı Kılavuzuna ve CLI Kılavuzuna bakın. Kılavuzlar, yetkilimizin indirme merkezinde bulunabilir. website: https://support.omadanetworks.com/product/.
CLI Kullanımı Anahtara CLI üzerinden erişmek için bir Telnet veya SSH bağlantısı kurun.

Yapılandırma 27

Omada Campus Stackable L3 Managed Switch

Anahtara erişmek için konsol bağlantı noktasını kullanın. Konsol bağlantı noktasını kullanırken, bilgisayarda terminal emülasyon programını (Hiper Terminal gibi) başlatın ve terminal emülasyon programını aşağıdaki gibi yapılandırın:

Baud Hızı 38400 bps

Veri Bitleri 8

Parite Yok

Bitleri Durdur 1

Akış Kontrolü Yok

Ayrıntılı yapılandırmalar için Kullanıcı Kılavuzuna ve CLI Kılavuzuna bakın. Kılavuzlar, yetkilimizin indirme merkezinde bulunabilir. website: https://support.omadanetworks.com/product/.
Note: You may need to change the password the first time you log in, which will better protect your network and devices.

4.3 Kontrolör Modu
Controller Mode applies to the large scale network with mass devices. All devices can be centrally configured and monitored via Omada Pro Hardware Controller (C5300), Omada Pro Software Controller, or Omada Pro Cloud-Based Controller.
Note: Before the following configurations, make sure the switch can access the internet. When using Omada Pro Hardware/Software/Cloud-based Controller, make sure the switch and the controller are in the same subnet. Typically, the switch obtains IP address from the DHCP server. You can check the switch’s IP address on the DHCP server.

Via Omada Pro Hardware Controller (C5300)

Omada Pro Hardware Controller (C5300) is a good alternative if you have no spare PC to keep running Omada Pro Software Controller in the network. It needs to be purchased additionally. Follow the steps below to configure the Omada Pro Hardware Controller (C5300).

Şekil 4-2

Manage the network via Omada Pro Hardware Controller (C5300)

Ağ Geçidi Anahtarı

Omada Pro Hardware Controller (C5300) EAP
28 Yapılandırma

EAP

EAP

Müşteriler

Omada Campus Stackable L3 Managed Switch

Note: Before you start, be sure to power up and connect your devices according to the topology figure. A DHCP server (typically a gateway with DHCP function enabled) is required to assign IP addresses to
the EAPs and clients in your local network. Omada Pro Controller must have network access to some Omada campus devices (the gateway,
switch, or APs) in order to find, adopt, and manage them.

1. Ağ geçidinin IP adresini bulun. Bilgisayarınızda komut satırını açın ve ipconfig yazın. Sonuç listesinde, ağ geçidinin IP adresi olan Varsayılan Ağ Geçidi'ni bulun.
2. Birini başlatın web tarayıcınıza gidin ve ağ geçidinin IP adresini girin. Ağ geçidinin web Daha sonra Ağ > LAN > DHCP İstemci Listesi'ne giderek kontrol cihazınızın MAC adresine göre IP adresini bulun.
3. Adres çubuğuna kontrol cihazınızın IP adresini girerek kontrol cihazınızı açın. web sayfa.
4. On the Omada Pro Controller’s web Sayfayı açın, hızlı kurulumu tamamlamak için sihirbazı izleyin.
5. Hızlı kurulumdan sonra oturum açma sayfası görünür. Oluşturduğunuz kullanıcı adını ve parolayı girin ve Oturum aç'a tıklayın. Ardından denetleyiciyi daha fazla yapılandırabilirsiniz.
6. Cihazları uzaktan yönetmek istiyorsanız, aşağıdaki adımları izleyin:
a. Denetleyicinizde Cloud Access'in etkinleştirildiğinden emin olun. Varsayılan olarak Cloud Access etkindir. Cloud LED'inin yavaşça yanıp söndüğünden emin olun.

b. Birini başlatın web tarayıcı ve adres çubuğuna https://omada.tplinkcloud.com girin. Oturum açmak için TP-Link kimliğinizi ve parolanızı girin. + Denetleyici Ekle'ye tıklayın ve denetleyicinizi eklemek için Donanım Denetleyicisi'ni seçin. Ardından denetleyiciyi daha fazla yapılandırabilirsiniz.

For more details, refer to the Installation Guide of C5300.

Omada Pro Yazılım Denetleyicisi aracılığıyla

Download the Omada Pro Software Controller on a PC with Windows OS or Linux OS. Then run the file and follow the wizard to install the Omada Pro Software Controller. Follow the steps below to configure the Controller.

Şekil 4-3

Ağı Omada Pro Yazılım Denetleyicisi aracılığıyla yönetin

Geçit

Anahtar

Kontrolör

Omada Pro Yazılım Denetleyicisi AP

AP

AP

Ana PC'de çalışan

Müşteriler

Yapılandırma 29

Omada Campus Stackable L3 Managed Switch

1. Launch the Omada Pro Software Controller on your PC. After the initiation process, the controller automatically opens its web sayfa. Değilse, Ağı Yönetmek İçin Bir Tarayıcı Başlat'a tıklayın.
2. On the Omada Pro Controller’s web Sayfayı açın, hızlı kurulumu tamamlamak için sihirbazı izleyin.
3. Hızlı kurulumdan sonra oturum açma sayfası görünür. Oluşturduğunuz kullanıcı adını ve parolayı girin ve Oturum aç'a tıklayın. Ardından denetleyiciyi daha fazla yapılandırabilirsiniz.
4. Cihazları uzaktan yönetmek istiyorsanız, aşağıdaki adımları izleyin:
a. Make sure that Cloud Access is enabled on your controller and your controller has been bound with your TP-Link ID. On the Omada Pro Controller’s web sayfasında, Ayarlar > Bulut Erişimi'ne gidin ve Bulut Erişimi'ni etkinleştirin ve TP-Link Kimliğinizi bağlayın. Hızlı kurulumda ayarladıysanız, bu adımı atlayın.
b. Birini başlatın web tarayıcı ve adres çubuğuna https://omada.tplinkcloud.com girin. Oturum açmak için TP-Link Kimliğinizi ve parolanızı girin. TP-Link Kimliğinize bağlı olan denetleyicilerin bir listesi görünecektir. Ardından, denetleyiciyi daha fazla yapılandırmak için Başlat'a tıklayabilirsiniz.

Note: To manage your devices, Omada Pro Software Controller needs to keep running on your computer.

Omada Pro Bulut Tabanlı Denetleyici aracılığıyla

Omada Pro Bulut Tabanlı Denetleyici, yazılım denetleyicisini bir PC'ye yüklemeye gerek kalmadan iyi bir alternatiftir.

Lisansların ayrıca satın alınması gerekmektedir.

Şekil 4-4

Ağı Omada Pro Bulut Tabanlı Denetleyici aracılığıyla yönetin

Omada Bulutu

Geçit

Anahtar

AP

AP

AP

AP

Müşteriler
1. Contact the sales staff to grant the Omada Pro Cloud-Based Controller permission. 2. Launch a web browser and enter https://omada.tplinkcloud.com in the address bar. Log in with
your TP-Link ID.
30 Yapılandırma

Omada Campus Stackable L3 Managed Switch 3. Click + Add Controller and choose Cloud-Based Controller to add an Omada Pro Controller. Then
you can launch the controller to adopt and manage devices. * Omada App With the Omada app, you can also manage your controller at a local site or a remote site via your mobile device. For the detailed configurations, refer to the User Guide of the controller. The guide can be found on the download center of our official website: https://support.omadanetworks.com/product/.
Yapılandırma 31

Omada Campus Stackable L3 Managed Switch
Ek A Sorun Giderme
S1. Anahtarın kullanıcı adını ve şifresini unutursam ne yapabilirim?
1. Bilgisayarınızın konsol portunu switch’in konsol portuna bağlayın ve terminal emülasyon programını açın.
2. Anahtarı kapatın ve yeniden başlatın. BootUtil menüsüne ulaşmak için terminal emülasyon programı tarafından belirtilen eylemi gerçekleştirin. Eylem üründen ürüne farklılık gösterir. Olası eylemler aşağıda listelenmiştir: · Otomatik önyüklemeyi durdurmak için herhangi bir tuşa basın. · BootUtil menüsüne ulaşmak için CTRL-B'ye basın.
3. bootUtil menüsü görüntülenecektir. "Parola kurtarma" seçeneğini seçmek için 6 rakamını girin ve tüm kullanıcıları ve parolaları silmek için Y tuşuna basın. Ardından kullanıcı adı ve parolayı sıfırlayabilirsiniz.
S2. PWR LED'i neden anormal çalışıyor? Güç sistemi normal çalıştığında PWR/Güç LED'i yanmalıdır. PWR/Güç LED'i anormal çalışıyorsa, aşağıdaki adımları izleyin:
1. Güç kablosunun düzgün bağlandığından ve güç kontağının normal olduğundan emin olun. 2. Voltajın düşük olduğundan emin olun.tagGüç kaynağının e'si giriş hacmi gereksinimini karşılartage'nin
anahtar.
S3. Erişim sağlayamıyorsam ne yapmalıyım? web Yönetim sayfanız mı var? Aşağıdakileri deneyin:
1. Anahtardaki her port LED'ini kontrol edin ve Ethernet kablosunun düzgün bir şekilde bağlandığından emin olun. 2. Anahtardaki başka bir portu deneyin ve Ethernet kablosunun uygun olduğundan ve normal şekilde çalıştığından emin olun. 3. Anahtarı kapatın ve bir süre sonra tekrar açın. 4. Bilgisayarınızın IP adresinin anahtarın alt ağında ayarlandığından emin olun. 5. Yapılandırma sayfasına hala erişemiyorsanız anahtarı fabrika varsayılanlarına sıfırlayın. Ardından
Bilgisayarınızın IP adresi 192.168.0.x (“x” 2 ile 254 arasında herhangi bir sayıdır) ve alt ağ maskesi 255.255.255.0 olarak ayarlanmalıdır.
S4. Terminal öykünme programı neden düzgün görüntülenmiyor? Aşağıdakileri deneyin:
1. Güç kaynağının normal olduğundan ve konsol kablosunun düzgün şekilde bağlandığından emin olun. 2. Konsol kablosunun doğru tipte olup olmadığını kontrol edin. 3. Terminal emülasyon programının parametrelerinin doğru olduğundan emin olun: Bits per second'ı yapılandırın
38400 olarak, Veri bitleri 8 olarak, Parite Yok olarak, Durdurma bitleri 1 olarak ve Akış kontrolü Yok olarak.
32 Ek A Sorun Giderme

Omada Campus Stackable L3 Managed Switch

Ek B Özellikler

Specifications for S6500 Series Switches

Öğe

İçerik

IEEE 802.3, IEEE 802.3i, IEEE 802.3u, IEEE 802.3ab, IEEE 802.3z, IEEE 802.3ae, IEEE 802.3x

Standartlar

IEEE 802.3af/at (For S6500-24GP4XF, S6500-48GP6XF) IEEE 802.3af/at/bt (For S6500-24MPP4Y, S6500-48MPP6Y)

IEEE 802.3bz, IEEE 802.3by, IEEE 802.3cc (For S6500-24M4Y, S6500-24MPP4Y, S6500-48M6Y, S6500-48MPP6Y)

10BASE-T: 2-pair UTP/STP of Cat. 3,4,5 (maximum 100 m) 100BASE-TX: 2-pair UTP/STP of Cat. 5 or above (maximum 100 m) 1000BASE-T: 4-pair UTP/STP of Cat. 5e or above (maximum 100 m) 2.5GBASE-T: 4-pair UTP/STP of Cat. 5e or above (maximum 100 m) Transmission Medium 1000BASE-SX/LX/LX10/BX10: MMF, SMF 10GBASE-SR/LR: MMF, SMF 10G SFP+ Direct Attach Cable (SM5220-1M, SM5220-3M) 25GBASE-SR/LR: MMF, SMF (SM6110-SR, SM6110-LR) 25G SFP28 Direct Attach Cable (SM6220-1M)

S6500-24G4XF/S6500-24M4Y: PWR1, PWR2, SYS, FAN, MGMT, MST, SPEED, STK, Port 1-24, Port 25-28 S6500-24GP4XF/S6500-24MPP4Y: PWR1, PWR2, SYS, FAN, PoE Max, MGMT, MST, SPEED, STK, PoE, Port 1-24, Port 25-28 LED S6500-48G6XF/S6500-48M6Y: PWR1, PWR2, SYS, FAN, MGMT, MST, SPEED, STK, Port 1-48, Port 49-54 S6500-48GP6XF/S6500-48MPP6Y: PWR1, PWR2, SYS, FAN, PoE Max, MGMT, MST, SPEED, STK, PoE, Port 1-48, Port 49-54

Ek B Teknik Özellikler 33

Omada Campus Stackable L3 Managed Switch

PoE Bütçesi

For S6500-24GP4XF: 402W (with 1*PSM500-AC, by default) 720W (with 1*PSM900-AC) 720W (with 2*PSM500-AC) 720W (with 1*PSM500-AC and 1*PSM900-AC) 720W (with 2*PSM900-AC) For S6500-48GP6XF: 764W (with 1*PSM900-AC, by default) 384W (with 1*PSM500-AC) 812W (with 2*PSM500-AC) 1176W (with 1*PSM500-AC and 1*PSM900-AC) 1440W (with 2*PSM900-AC) For S6500-24MPP4Y: 751W (with 1*PSM900-AC, by default) 378W (with 1*PSM500-AC) 802W (with 2*PSM500-AC) 1168W (with 1*PSM500-AC and 1*PSM900-AC) 1534W (with 2*PSM900-AC) For S6500-48MPP6Y: 701W (with 1*PSM900-AC, by default) 328W (with 1*PSM500-AC) 752W (with 2*PSM500-AC) 1118W (with 1*PSM500-AC and 1*PSM900-AC) 1484W (with 2*PSM900-AC)

Operating Temperature & Altitude

For S6500-24G4XF/S6500-48G6XF/S6500-24M4Y/S6500-48M6Y: -5 °C to 50 °C (23 °F to 122 °F) @ 300 meters -5 °C to 45 °C (23 °F to 113 °F) @ 2,000 meters -5 °C to 40 °C (23 °F to 104 °F) @ 3,000 meters For S6500-24GP4XF/S6500-48GP6XF/S6500-24MPP4Y/S6500-48MPP6Y: -5 °C to 45 °C (23 °F to 113 °F) @ 2,000 meters -5 °C to 40 °C (23 °F to 104 °F) @ 3,000 meters

Depolama Sıcaklığı -40 °C ila 70 °C (-40 °F ila 158 °F)

Çalışma Nemi %10 ila %90 RH, Yoğuşmasız

Depolama Nemi

%5 ila %90 RH Yoğuşmasız

34 Ek B Teknik Özellikler

Omada Campus Stackable L3 Managed Switch

Specifications for S7500 Series Switches

Öğe

İçerik

Standartlar

IEEE 802.3, IEEE 802.3x IEEE 802.3z, IEEE 802.3ae (For S7500-26XF6Y, S7500-48XF4C, S7500-24Y4C, S7500-48Y8C IEEE 802.3by, IEEE 802.3cc (For S7500-26XF6Y, S7500-24Y4C, S7500-48Y8C) IEEE 802.3 ba, IEEE 802.3bm (For S7500-48XF4C , S7500-24Y4C, S7500-48Y8C, S7500-32C)

1000BASE-SX/LX/LX10/BX10: MMF, SMF 10GBASE-SR/LR: MMF, SMF 10G SFP+ Direct Attach Cable (SM5220-1M, SM5220-3M) 25GBASE-SR/LR: MMF, SMF (SM6110-SR, SM6110-LR) 25G SFP28 Direct Attach Cable (SM6220-1M) 40GBASE-SR4/LR4: MMF, SMF (For S7500-48XF4C, S7500-24Y4C, Transmission Medium S7500-48Y8C, S7500-32C) 40G QSFP+ Direct Attach Cable (For S7500-48XF4C, S7500-24Y4C, S7500-48Y8C, S7500-32C) 100GBASE-SR4/LR4: MMF, SMF (SM9110-SR4 for S7500-48XF4C, S7500-24Y4C, S7500-48Y8C, S7500-32C) 100G QSFP28 Direct Attach Cable (SM9220-1M for S7500-48XF4C, S7500-24Y4C, S7500-48Y8C, S7500-32C)

NEDEN OLMUŞ
Operating Temperature & Altitude

S7500-26XF6Y: PWR1, PWR2, SYS, FAN, MGMT, MST, SPD, STK, SFP+, SFP28 S7500-48XF4C: PWR1, PWR2, SYS, FAN, MGMT, MST, SPEED, STK, SFP+, QSFP28 S7500-24Y4C: PWR1, PWR2, SYS, FAN, MGMT, MST, SPD, STK, SFP28, QSFP28 S7500-48Y8C: PWR1, PWR2, SYS, FAN, MGMT, MST, SPEED, STK, SFP28, QSFP28 S7500-32C: PWR1, PWR2, SYS, MGMT, FAN, MST, SPEED, STK, QSFP28 -5 °C to 45 °C (23 °F to 113 °F) @ 300 meters -5 °C to 40 °C (23 °F to 104 °F) @ 2,000 meters -5 °C to 35 °C (23 °F to 95 °F) @ 3,000 meters

Depolama Sıcaklığı -40 °C ila 70 °C (-40 °F ila 158 °F)

Çalışma Nemi %10 ila %90 RH, Yoğuşmasız

Depolama Nemi

%5 ila %90 RH Yoğuşmasız

For S7500-26XF6Y, S7500-48XF4C, and S7500-24Y4C, the maximum operating temperature supported can reach 50 °C (122 °F) @ 300 meters, 45 °C (113 °F) @ 2,000 meters, and 40 °C (104 °F) @ 3,000 meters.
Desteklenen rakım deniz seviyesinden 5000 m'ye kadardır. Rakım 2000 m'nin üzerinde olduğunda, her 220 metrelik rakım artışında maksimum çalışma sıcaklığının 1°C (1.8°F) düşeceği unutulmamalıdır.

Ek B Teknik Özellikler 35

Omada Campus Stackable L3 Managed Switch

Güç Kaynağı Modüllerinin Özellikleri

PSM500-AC
(For S6500-24GP4XF/ S6500-48GP6XF/ S6500-24MPP4Y/ S6500-48MPP6Y)

PSM900-AC
(For S6500-24GP4XF/ S6500-48GP6XF/ S6500-24MPP4Y/ S6500-48MPP6Y)

PSM550-AC
(For S6500-24M4Y/ S6500-48M6Y/ S7500-26XF6Y/ S7500-48XF4C/ S7500-24Y4C/ S7500-48Y8C/ S7500-32C)

Güç Girişi

100 V­240 V~ 50/60 Hz 8A

100-120V (included)~ 50/60Hz 12A (for locations using low voltage, see specifications for specific countries/ regions)
120 (not included)240V~ 50/60Hz 10A (for other locations)

100 V­240 V~ 50/60 Hz 7A

Çıkış Hacmitage

Primary: 53.5 VDC Standby: 12 VDC

Primary: 53.5 VDC Standby: 12 VDC

Primary: 12 VDC Standby: 12 VDC

Çıkış Akımı

9.35 A (Maksimum)

16.5 A (Maksimum)

45 A (Maksimum)

Çıkış Gücü

500 W (Maksimum)

900 W (Maksimum)

550 W (Maksimum)

Çalışma Yüksekliği

For PSM500-AC/PSM900-AC: Sea level to 3000 m For PSM550-AC: Sea level to 5000 m

36 Ek B Teknik Özellikler

CE İşareti Uyarısı
Bu bir A sınıfı üründür. Ev ortamında, bu ürün radyo parazitine neden olabilir, bu durumda kullanıcının yeterli önlemleri alması gerekebilir.
AB Uygunluk Beyanı
TP-Link, anahtarın 2014/30/EU, 2014/35/EU, 2011/65/EU ve (EU)2015/863 sayılı direktiflerin temel gerekliliklerine ve diğer ilgili hükümlerine uygun olduğunu beyan eder. Orijinal AB Uygunluk Beyanı'na https://www.tp-link.com/en/support/ce/ adresinden ulaşılabilir.
İngiltere Uygunluk Beyanı
TP-Link, bu anahtarın Elektromanyetik Uyumluluk Yönetmelikleri 2016 ve Elektrikli Ekipman (Güvenlik) Yönetmelikleri 2016'nın temel gereklilikleri ve diğer ilgili hükümleriyle uyumlu olduğunu beyan eder. Orijinal Birleşik Krallık Uygunluk Beyanı'na https://www.tp-link.com/support/ukca/ adresinden ulaşılabilir.
, .
DİKKAT:
Çift kutuplu, nötr sigorta. Servisten önce şebeke bağlantısını kesin.
Güvenlik Bilgileri
· Cihazı sudan, ateşten, nemden veya sıcak ortamlardan uzak tutun. · Cihazı sökmeye, onarmaya veya değiştirmeye çalışmayın. Servise ihtiyacınız varsa lütfen bizimle iletişime geçin. · Cihazı alt yüzeyi aşağı bakacak şekilde yerleştirin. · Güç kaynağı kablosundaki fiş, bağlantı kesme cihazı olarak kullanılır, priz
Kolayca erişilebilir. · Ürünü, güç kaynağı kablosu aracılığıyla topraklama bağlantısı olan duvar prizlerine takın
or plug. · The socket-outlet shall be installed near the equipment and shall be easily accessible. · The PoE ports shall not be used to charge lithium batteries or devices supplied by lithium
piller.

· Operating temperature: For S6500-24G4XF/S6500-48G6XF/S6500-24M4Y/S6500-48M6Y/S7500-26XF6Y/ S7500-48XF4C/S7500-24Y4C: -5 °C to 50 °C (23 °F to 122 °F) @ 300 meters -5 °C to 45 °C (23 °F to 113 °F) @ 2,000 meters -5 °C to 40 °C (23 °F to 104 °F) @ 3,000 meters For S6500-24GP4XF/S6500-48GP6XF/S6500-24MPP4Y/S6500-48MPP6Y: -5 °C to 45 °C (23 °F to 113 °F) @ 2,000 meters -5 °C to 40 °C (23 °F to 104 °F) @ 3,000 meters S7500-48Y8C/S7500-32C: -5 °C to 45 °C (23 °F to 113 °F) @ 300 meters -5 °C to 40 °C (23 °F to 104 °F) @ 2,000 meters -5 °C to 35 °C (23 °F to 95 °F) @ 3,000 meters
· : S6500-24G4XF/S6500-48G6XF/S6500-24M4Y/S6500-48M6Y/S7500-26XF6Y/S7500-48XF4C/ S7500-24Y4C -5°C 50°C23°F 122°F@ 300 -5°C 45°C23°F 113°F@ 2,000 -5°C 40°C23°F 104°F@ 3,000 S6500-24GP4XF/S6500-48GP6XF/S6500-24MPP4Y/S6500-48MPP6Y -5°C 45°C23°F 113°F@ 2,000 -5°C 40°C23°F 104°F@ 3,000 S7500-48Y8C/S7500-32C -5°C 45°C23°F 113°F@ 300 -5°C 40°C23°F 104°F@ 2,000 -5°C 35°C23°F 95°F@ 3,000
This equipment is not suitable for use in locations
where children are likely to be present.

Lütfen cihazı çalıştırırken yukarıdaki güvenlik bilgilerini okuyun ve uygulayın. Cihazın yanlış kullanımından dolayı herhangi bir kaza veya hasar meydana gelmeyeceğini garanti edemeyiz. Lütfen bu ürünü dikkatli kullanın ve kendi riskinizle çalıştırın.

Teknik destek, kullanıcı kılavuzları ve diğer bilgiler için lütfen https://support.omadanetworks.com/ adresini ziyaret edin veya QR kodunu tarayın.
© 2026 TP-Link 7100002759 REV2.0.1

Belgeler / Kaynaklar

Omada L3 Campus Stackable Managed Switch [pdf] Kullanıcı Kılavuzu
L3Campus Stackable Managed Switch, L3, Campus Stackable Managed Switch, Stackable Managed Switch, Managed Switch, Switch

Referanslar

Yorum bırakın

E-posta adresiniz yayınlanmayacak. Gerekli alanlar işaretlenmiştir *