Corning CCH-CS12-AE-P00RE Pigtailed Splice Cassette Kullanım Kılavuzu

Model: CCH-CS12-AE-P00RE

1. Üzeriview

The Corning CCH Pigtailed Splice Cassette, model CCH-CS12-AE-P00RE, is designed to facilitate faster field splicing and provide modular management of connectorization within fiber optic housings. This cassette is preloaded and pre-routed for efficient fusion splicing of individual or ribbon fiber pigtails, utilizing the same space-saving platform as standard CCH splice cassettes. It aims to reduce field labor by streamlining components and features, allowing for greater efficiency in fiber optic installations.

The cassette is prepped with a 3-meter pigtail assembly, compatible with all pre-existing CCH panel connector options. It features 900 µm cabling at the connector panel for enhanced durability and colored 250 µm fibers for ease of splicing. Strain relief is pre-applied from the manufacturing facility. This modular design allows for easy access to fibers within an individual cassette without disturbing other fibers in the housing.

2. Temel Özellikler

3. Kutuda Neler Var?

The package for the Corning CCH-CS12-AE-P00RE Pigtailed Splice Cassette typically includes the following components:

Corning CCH-CS12-AE-P00RE Pigtailed Splice Cassette in its retail packaging.

Figure 1: The Corning CCH-CS12-AE-P00RE Pigtailed Splice Cassette as packaged, showing the front view with product labels and connectors.

4. Kurulum ve Kurulum

The CCH pigtailed splice cassette is designed for straightforward installation within compatible Corning CCH housings. The pre-routed pigtails and included accessories simplify the splicing process.

4.1. Genel Kurulum Adımları

  1. Housing Preparation: Ensure your CCH-01U, CCH-02U, CCH-03U, or CCH-04U housing is properly mounted and ready for cassette insertion.
  2. Cassette Insertion: Slide the pigtailed splice cassette into the designated slot within the CCH housing. Use the appropriate rails provided (one rail for 01U/02U/03U, two rails for 04U).
  3. Incoming Cable Routing: Route the incoming fiber optic cable into the housing and through the protective braided tubing provided. Secure the cable using the grommets and cable ties for strain relief.
  4. Pigtail Routing: The pigtails are pre-routed within the cassette. Ensure they are not kinked or excessively bent.
  5. Ekleme: Perform fusion splicing of the incoming fibers to the 250 µm colored pigtail fibers. The modular design allows splicing to be done away from the rack housing in a suitable workspace, if preferred. Utilize the included heat-shrink splice protectors for each splice.
  6. Connectorization: Connect the LC UPC duplex shuttered connectors to the appropriate ports on your equipment or patch panel.

4.2. Routing Diagrams and Details

Diagrams illustrating fiber routing within Corning CCH housings, pigtail layer, splice tray layer, and incoming cable layer for the splice cassette.

Figure 2: Detailed routing diagrams for the CCH-CS12-AE-P00RE cassette, showing fiber paths for 1U/2U/3U housings, pigtail management, splice tray layout, and incoming cable routing. For 4U routing, refer to Corning document SRP 003-895.

For detailed routing instructions specific to your CCH housing type, refer to the diagrams provided on the product packaging and the official Corning documentation. Specifically, for 4U routing, consult Corning document SRP 003-895.

Taraf view of the Corning CCH-CS12-AE-P00RE Pigtailed Splice Cassette, showing the LC UPC duplex shuttered connectors and the transparent cover.

Şekil 3: Yan view of the CCH-CS12-AE-P00RE cassette, highlighting the LC UPC duplex shuttered connectors and the compact design.

4.3. Important Resources

5. Operasyon

The Corning CCH Pigtailed Splice Cassette is a passive component designed to organize and protect fiber optic splices and connections within a fiber optic housing. Its primary function is to provide a secure and accessible environment for fusion splicing and subsequent connection to active equipment or patch panels.

5.1. Fiber Management

Once installed and spliced, the cassette effectively manages the fiber slack and protects the delicate splice points. The modular design allows for individual cassette access, meaning you can work on or inspect fibers within one cassette without disturbing the connections or splices in adjacent cassettes within the same housing.

5.2. Bağlantı

The LC UPC duplex shuttered connectors on the cassette provide a reliable interface for connecting to network devices, switches, or other fiber optic equipment. The shutters protect the ferrule ends from dust and debris when not in use, maintaining optimal signal integrity.

6. Bakım

Proper maintenance of fiber optic components is crucial for ensuring long-term performance and reliability. While the CCH splice cassette itself requires minimal maintenance, the connected fibers and connectors do.

6.1. Konnektör Temizliği

Regular cleaning of the LC UPC duplex connectors is highly recommended. Dust, dirt, and oils can significantly degrade optical performance. Use only approved fiber optic cleaning tools and methods, such as lint-free wipes with isopropyl alcohol or specialized one-click cleaners. Always inspect connectors with a fiber inspection microscope before and after cleaning.

6.2. Kablo Yönetimi

Ensure that all incoming and outgoing cables are properly routed and secured within the housing, avoiding sharp bends or excessive tension. Verify that strain relief mechanisms (grommets, cable ties) are functioning correctly.

6.3. Çevresel Hususlar

Keep the housing and cassette free from dust and moisture. Operate within the specified environmental conditions to prevent damage to the fiber optic components.

7. Sorun Giderme

Most issues related to fiber optic connectivity stem from dirty connectors, damaged fibers, or improper splicing. The CCH splice cassette itself is a passive component and is unlikely to be the direct cause of signal issues unless physically damaged.

7.1. Yaygın Sorunlar ve Çözümleri

If issues persist after performing these checks, it is recommended to use specialized fiber optic testing equipment (e.g., Optical Power Meter, OTDR) to diagnose the exact location and nature of the fault.

8. Teknik Özellikler

BağlanmakDetay
Parça NumarasıCCH-CS12-AE-P00RE
Lif Sayısı12 Lif
Elyaf TürüTek modlu (OS2)
Bağlayıcı TürüLC Duplex Shuttered
Lehçe TipiUPC
Pigtail Uzunluğu3 metre
Cable Type (Pigtail)250 µm colored fibers, 900 µm at connector panel
Splice Protectors Included12 heat-shrink splice protectors
Uyumlu MuhafazalarCorning CCH-01U, CCH-02U, CCH-03U, CCH-04U
Paket Boyutları14 x 8 x 3 inç
Ürün Ağırlığı3 Pound
ÜreticiCorning
İlk Mevcut Tarih7 Ağustos 2025

9. Garanti Bilgileri

Specific warranty terms and conditions for the Corning CCH-CS12-AE-P00RE Pigtailed Splice Cassette are provided by the manufacturer, Corning. Please refer to the official documentation included with your product or visit the official Corning website for detailed warranty information, including coverage period, terms, and conditions.

Note: This manual does not constitute a warranty. All warranty claims must be made directly through Corning or an authorized reseller.

10. Destek ve İletişim Bilgileri

For technical support, product inquiries, or assistance with the Corning CCH-CS12-AE-P00RE Pigtailed Splice Cassette, please contact Corning directly.

10.1. Üreticiyle İletişim

Üretici: Corning

Please visit the official Corning website for the most up-to-date contact information, technical documentation, and support resources.

When contacting support, please have your product model number (CCH-CS12-AE-P00RE) and any relevant purchase details ready.

İlgili Belgeler - CCH-CS12-AE-P00RE

Önview Corning ve Arista 40G, 100G, 400G ve 800G Kablolama Referans Kılavuzu
A comprehensive guide from Corning Optical Communications detailing cabling scenarios, transceiver types, and part numbers for Arista networks supporting 40G, 100G, 400G, and 800G data rates. Includes local and across-data-center connections.
Önview Corning Everon 6000 MIMO Sistemi Kullanıcı Kılavuzu: Yapılandırmalar, LED'ler ve RF Özellikleri
Corning Optical Communications'ın Everon 6000 serisi MIMO sistemleri için ayrıntılı kullanım kılavuzu. dLRU, DEU, DCU, RIU, BTS, dMRU ve dHRU bileşenleriyle 2x2, 2TO1 ve 4TO1 yapılandırmalarını kapsar. Profesyonel kurulum için LED durum tanımları, sürüm sürümleri ve kritik RF maruziyet uyarıları içerir.
Önview Corning MRU ve HRU Kullanım Kılavuzu: Kurulum ve İşletim Kılavuzu
Bu kullanıcı kılavuzu, kablosuz ağ altyapısının temel bileşenleri olan Corning'in MRU (Dijital Orta Güçlü Uzak Ünite) ve HRU (Yüksek Güçlü Uzak Ünite) sistemlerinin kurulumu, yapılandırılması ve çalıştırılması için kapsamlı talimatlar sağlar.
Önview Corning Matribot Biyoyazıcı Kullanım Kılavuzu
Corning Matribot Biyobaskı Cihazı için kapsamlı kullanım kılavuzu; doku mühendisliği ve 3 boyutlu hücre kültürü alanlarındaki gelişmiş biyobaskı uygulamaları için kurulum, çalıştırma, bakım ve sorun giderme konularını ayrıntılı olarak açıklamaktadır.
Önview Everon 6000 G2(3500) Commissioning Instruction Manual
This manual provides detailed instructions for the commissioning and operation of the Everon 6000 G2(3500) system, covering hardware and software requirements, system connection diagrams, configuration procedures, and software upgrade processes.
Önview Corning KS500/KS250 RJ45 Keystone Cat.6A/6 Kurulum Talimatları
Corning KS500 ve KS250 RJ45 Keystone Jakları (Cat.6A/6, korumalı/korumasız) için kapsamlı kurulum kılavuzu. Hazırlık, kablolama, montaj ve sipariş bilgilerini içerir.