1. Giriş
The Elitech LogEt5T is a reusable USB temperature data logger designed for precise temperature monitoring across various applications, including biosciences, cold chain logistics, and industrial environments. It features automatic PDF and CSV report generation, a wide temperature range, and enhanced data integrity functions.
Temel Özellikler:
- Enhanced Shadow Data Function: Ensures data integrity even during accidental shutdowns or restarts.
- Reusable Temperature Logger: Wide temperature range of -30°C to 70°C with high accuracy (±0.1°C).
- Özelleştirilebilir Parametreler: Easily modify temperature units, alarm ranges, and logging intervals.
- Automatic PDF & CSV Reports: Generates reports automatically without additional software.
- On-screen Data Visualization: Displays current, max, min, MKT values, date, and recording points.

2. Kurulum
2.1 İlk Kurulum
- Pil Montajı: The device comes with a pre-installed CR2450 battery. Ensure it is properly seated.
- Software Installation (Optional for Advanced Features): For advanced functionalities and detailed analysis, download the Elitechlog software from the official Elitech website. This software is compatible with Windows and macOS.
2.2 Customizing Parameters
Before starting a new recording, you can customize various parameters using the Elitechlog software:
- Sıcaklık birimleri (°C/°F)
- Alarm thresholds (high and low temperature limits)
- Logging interval (how frequently data is recorded)
- Başlangıç gecikmesi
- Şifre koruması

3. Kullanım Talimatları
3.1 Kayıt Başlatma
Basılı tutun BAŞLANGIÇ button on the device until the recording indicator appears on the LCD screen. The device will begin logging data according to the configured interval.
3.2 Kaydı Durdurma
Basılı tutun DURMAK button on the device until the recording indicator disappears. The device will cease logging data.
3.3 Viewing Data on Screen
The LCD screen provides real-time and summary data. Press the BAŞLANGIÇ Farklı ekran modları arasında geçiş yapmak için düğmeye kısa süre basın:
- Mevcut Sıcaklık
- Maximum Temperature (MAX)
- Minimum Temperature (MIN)
- Average Temperature (AVG)
- Ortalama Kinetik Sıcaklık (MKT)
- Tarih ve Saat
- Number of Recorded Points (LOG)

3.4 Data Export and Report Generation
To access recorded data:
- Connect the LogEt5T to a computer's USB port.
- The device will automatically generate a PDF report and a CSV file containing all recorded data. These files can be found in the device's storage when connected to a computer.
- For more detailed analysis, open the Elitechlog software and import the data. The software allows for graphical comparison of data and trend analysis.

3.5 Reusing the Logger
The LogEt5T is reusable. To clear data and prepare for a new recording cycle:
- Cihazı bir bilgisayara bağlayın.
- Open the Elitechlog software.
- Perform a quick reset and confirm the action within the software.
Not: Always save historical data before resetting the device to prevent data loss.

4. Bakım
4.1 Pil Değişimi
The LogEt5T uses a CR2450 button cell battery. When the battery indicator on the LCD screen shows low power, replace the battery:
- Pil bölmesini dikkatlice açın.
- Eski CR2450 pili çıkarın.
- Kutupların doğru olduğundan emin olarak yeni bir CR2450 pil takın.
- Pil bölmesini sıkıca kapatın.
4.2 Temizlik ve Depolama
- Cihazı yumuşak ve kuru bir bezle temizleyin. Aşındırıcı temizleyiciler veya çözücüler kullanmayın.
- Cihazı serin, kuru ve doğrudan güneş ışığından ve aşırı sıcaklıklardan uzak bir yerde saklayın.
- Ensure the USB port is protected from moisture and dust when not in use.
5. Sorun Giderme
Yaygın Sorunlar ve Çözümleri:
- Device not starting: Pil seviyesini kontrol edin. Düşükse değiştirin.
- No data export: Ensure the device is properly connected to the USB port. Try a different USB port or cable.
- Yazılım cihazı tanımıyor: Ensure Elitechlog software is installed correctly. Restart the software and reconnect the device.
- Yanlış okumalar: Ensure the device is placed in an appropriate environment, away from direct heat sources or extreme drafts. Refer to specifications for operating range.
For further assistance, consult the Elitechlog software's help section or contact Elitech customer support.
6. Özellikler
The following table details the technical specifications of the Elitech LogEt5T USB Temperature Data Logger:
| Özellik | Şartname |
|---|---|
| Model Adı | LogEt5T |
| Sıcaklık Aralığı | -30°C ila 70°C (-22°F ila 158°F) |
| Sıcaklık Doğruluğu | ±0.5°C (-20~40°C), ±1°C (-100~150°C), ±2°C (others) |
| Veri Depolama Kapasitesi | 32,000 puan |
| Günlük Aralığı | Configurable (from 10 seconds to 24 hours) |
| Bağlantı Teknolojisi | USB |
| Görüntü Türü | Dijital lcd |
| Güç Kaynağı | Battery powered (1x CR2450, included) |
| Malzeme | Paslanmaz Çelik (dış) |
| Boyutlar | 97mm x 43mm x 12.5mm |
| Ağırlık | 80 gram |
| Uyumluluk | FDA 21 CFR Bölüm 11 |


7. Garanti ve Destek
For information regarding product warranty, technical support, or service, please refer to the official Elitech website or contact Elitech customer service directly. Details are typically provided with the product packaging or available online.
Ayrıca ziyaret edebilirsiniz Elitech Brand Store on Amazon Daha fazla ürün bilgisi ve destek kaynakları için.