Pulsar PGiPAIRB4

Pulsar PGiPAIRB4 Inverter Generator Parallel Kit

Kullanım Kılavuzu

giriiş

This manual provides essential instructions for the safe and efficient use of your Pulsar PGiPAIRB4 Inverter Generator Parallel Kit. This kit allows you to connect two compatible Pulsar inverter generators to double their power output, providing increased electrical capacity for various applications, including RV use.

Compatible Pulsar Generator Models: PGDA70BiSCO, PGD95BiSCO, PGD105TiSCO.

Güvenlik Bilgileri

Always read and understand all safety warnings and instructions in this manual and the manuals of your connected generators before operation. Failure to follow these instructions can result in serious injury or property damage.

  • Ensure all connections are secure before starting generators.
  • Operate generators in a well-ventilated area to prevent carbon monoxide poisoning.
  • Islak zeminde çalışmayın.
  • Keep children and pets away from operating equipment.
  • Always turn off generators and disconnect spark plug wires before performing any maintenance or making connections.

Paket İçeriği

Paketinizde tüm öğelerin mevcut olduğundan emin olun:

  • Pulsar PGiPAIRB4 Parallel Kit Unit
  • Connection Cables (integrated)
  • Kullanım Kılavuzu (bu belge)
Pulsar PGiPAIRB4 Parallel Kit unit with cables

Image: The Pulsar PGiPAIRB4 Parallel Kit unit, showing the main box with receptacles and circuit breakers, and the integrated connection cables extending from it.

Kurulum ve Bağlantı

Follow these steps to connect your parallel kit to two compatible Pulsar inverter generators:

  1. Hazırlık: Ensure both generators are turned off, cooled down, and disconnected from any loads. Place the generators on a level, stable surface in a well-ventilated area.
  2. Connect Parallel Cables: Locate the parallel connection ports on each generator. These are typically color-coded (red and black) and may have specific shapes.
    Close-up of parallel connection cables

    Resim: Yakın çekim view of the parallel kit's connection cables, showing the red and black connectors designed to plug into the generators.

    Connect the red cable from the parallel kit to the red parallel port on the first generator. Connect the black cable from the parallel kit to the black parallel port on the first generator. Repeat this process for the second generator.
    Close-up of parallel connection adapters

    Image: Various parallel connection adapters and plugs, illustrating the types of connections used for linking generators.

  3. Güvenli Bağlantılar: Ensure all connections are firmly seated and secure. Loose connections can cause arcing or power interruptions.
  4. Son Yerleştirme: Position the parallel kit unit in a safe, accessible location, away from exhaust fumes and moisture.
    Two Pulsar generators connected with the parallel kit

    Image: Two Pulsar inverter generators shown from the rear, with the PGiPAIRB4 Parallel Kit connected to their respective parallel ports, demonstrating a complete setup.

Kullanım Talimatları

Once the parallel kit is securely connected to both generators:

  1. Start Generators: Start both inverter generators according to their individual operating instructions. Allow them to run for a few moments to stabilize.
  2. Yükleri Bağla: Plug your electrical loads into the receptacles on the PGiPAIRB4 Parallel Kit.
    • The L14-50 receptacle provides 120/240V output at 50 amps.
    • The L14-30 receptacle provides 120/240V output at 30 amps.
  3. İzleme: Observe the generator and parallel kit for proper operation. The circuit breakers on the parallel kit will trip if an overload occurs.
  4. Kapat: To shut down, first disconnect all loads from the parallel kit. Then, turn off both generators according to their individual instructions. Finally, disconnect the parallel kit cables.

Bakım

The Pulsar PGiPAIRB4 Parallel Kit requires minimal maintenance. Follow these guidelines:

  • Keep the unit clean and free of dirt, dust, and moisture.
  • Inspect cables and connectors regularly for any signs of wear, damage, or corrosion. Replace if necessary.
  • Store the kit in a dry, protected area when not in use.

Sorun giderme

SorunOlası NedenÇözüm
No power output from parallel kit.
  • Generators not started.
  • Gevşek bağlantılar.
  • Devre kesici devreye girdi.
  • Incompatible generators.
  • Ensure both generators are running.
  • Check all parallel cable connections.
  • Reset the circuit breaker on the parallel kit.
  • Verify generators are listed as compatible models.
Sigorta sık sık atıyor.
  • Aşırı yük durumu.
  • Arızalı cihaz.
  • Reduce the total electrical load.
  • Test appliances individually to identify faulty ones.

Özellikler

  • Modeli: PGiPAIRB4
  • Çıkış Hacmitage: 120/240V
  • Çıkış Frekansı: 60Hz
  • L14-50 Receptacle: 50 Amps
  • L14-30 Receptacle: 30 Amps
  • Uyumlu Jeneratörler: Pulsar PGDA70BiSCO, PGD95BiSCO, PGD105TiSCO
  • Ürün Ölçüleri: 12 x 9 x 4 inç
  • Ürün Ağırlığı: 3 pound
  • Üretici: Pulsar

Garanti Bilgileri

For detailed warranty information regarding your Pulsar PGiPAIRB4 Parallel Kit, please refer to the warranty card included with your purchase or visit the official Pulsar Products webSite. Satın alma belgenizi garanti talepleriniz için saklayın.

Müşteri Desteği

If you have any questions, require technical assistance, or need to order replacement parts, please contact Pulsar Customer Support:

  • Webalan: www.pulsarproducts.com
  • Refer to your product registration or warranty documentation for specific contact numbers or email addresses.

İlgili Belgeler - PGiPAIRB4

Önview Pulsar 9500 Watt Çift Yakıtlı İnverter Jeneratör Kullanım Kılavuzu
Bu kullanım kılavuzu, Pulsar PGD95BiSCO 9500 Watt Çift Yakıtlı İnverter Jeneratör için güvenlik önlemleri, çalıştırma, bakım ve sorun giderme konularını kapsayan kapsamlı talimatlar sunmaktadır.
Önview Pulsar PG2200BiS İnverter Benzinli Jeneratör Kullanım Kılavuzu
Pulsar PG2200BiS taşınabilir invertör benzinli jeneratör için kapsamlı kullanım kılavuzu, güvenilir performans sağlamak için güvenlik, çalıştırma, bakım ve sorun giderme konularını ele almaktadır.
Önview Pulsar PG2000iS/PG2300iS Portable Inverter Generator Operator's Manual
This operator's manual provides essential information for the safe operation, assembly, maintenance, and troubleshooting of the Pulsar PG2000iS and PG2300iS portable inverter gasoline generators. Learn how to use your generator effectively and safely.
Önview Pulsar 1600 Watt İnverter Jeneratör Kullanım Kılavuzu PGD16iSCO
Pulsar PGD16iSCO 1600 Watt İnverter Jeneratör için kapsamlı kullanım kılavuzu. Güvenli ve verimli kullanım için detaylı güvenlik talimatları, çalıştırma prosedürleri, bakım programları, sorun giderme kılavuzları ve teknik özellikler içerir.
Önview Pulsar PG2300iSCO İnverter Benzinli Jeneratör Kullanım Kılavuzu
Pulsar PG2300iSCO İnverter Benzinli Jeneratör için kapsamlı kullanım kılavuzu. Bu kılavuz, jeneratörün güvenli ve etkili kullanımı için gerekli olan güvenlik kuralları, ürün özellikleri, montaj talimatları, ayrıntılı çalıştırma prosedürleri, bakım programları, sorun giderme ipuçları ve bağlantı şeması dahil olmak üzere temel bilgileri kapsamaktadır.
Önview Pulsar PG4500BiSRCO İnverter Jeneratör Kullanım Kılavuzu
Pulsar PG4500BiSRCO İnverter Jeneratörü için benzin ve LPG çift yakıtlı kullanım için güvenlik, özellikler, çalıştırma, bakım ve sorun giderme konularını kapsayan kullanım kılavuzu.