1. Giriş

This manual provides essential information for the proper installation, operation, and maintenance of the Hoymiles HMS Field Connector BC05. This connector is specifically designed for use with Hoymiles HMS series micro-inverters to facilitate a secure and reliable electrical connection to the grid. Please read this manual thoroughly before installation and retain it for future reference.

Önemli Not: This connector is Olumsuz suitable for the Hoymiles HMT series micro-inverters.

2. Ürün Bittiview

The Hoymiles HMS Field Connector BC05 is a robust and weather-resistant electrical connector engineered for photovoltaic (PV) installations utilizing Hoymiles HMS series micro-inverters. It provides a quick and easy electrical connection between the micro-inverter and the AC grid, ensuring safety and performance. Its design emphasizes durability and ease of assembly in various environmental conditions.

Hoymiles HMS Field Connector BC05

Şekil 2.1: Hoymiles HMS Field Connector BC05. This image shows the assembled connector, highlighting its compact and durable design.

Hoymiles HMS Field Connector BC05 front view

Şekil 2.2: Ön view of the Hoymiles HMS Field Connector BC05. This perspective shows the three-pin electrical interface designed for secure connection.

3. Güvenlik Bilgileri

Always adhere to local electrical codes and regulations during installation. Improper installation can lead to electric shock, fire, or other hazards. Only qualified personnel should perform electrical installations.

4. Özellikler

The following table outlines the technical specifications for the Hoymiles HMS Field Connector BC05:

Technical Specifications Table for Hoymiles HMS Field Connector

Şekil 4.1: Technical Specifications for the HMS Field Connector. This image provides a detailed table of the connector's electrical and physical properties.

ParametreDeğer
Pin Numarası2P + P/E
Anma Hacmitage300V
Anma Akımı12 A (Use 1.5 mm² copper cable)
Applicable Cable Specification1.0 / 1.5 mm²
Applicable Cable Outer Diameter8 mm'den 9.5 mm'ye
Cable Connection TypeScrew Pressing
Ortam Sıcaklık Aralığı-40 °C ila +85 °C
Boyutlar (U × G × Y)135 × 38 × 25 mm
Koruma DerecesiIP68
Flame Resistance DegreeUL94-V0
UyumlulukRoHS
Ürün standardıPPP 59015A: 2013

5. Kurulum ve Kurulum

The HMS Field Connector BC05 is designed for straightforward assembly. Follow these steps for proper installation:

Patladı view of Hoymiles HMS Field Connector BC05 components

Şekil 5.1: Patladı view of the Hoymiles HMS Field Connector BC05. This image illustrates all individual components of the connector before assembly.

  1. Kabloyu Hazırlayın: Select a suitable cable (1.0 mm² or 1.5 mm² copper cable with an outer diameter of 8 mm to 9.5 mm). Strip the outer jacket of the cable to expose the individual conductors. Strip the insulation from the ends of the conductors to the recommended length for screw terminals. Consider using wire ferrules for optimal connection, especially with 1.5 mm² rubber hose lines (H07RN-F 3G1.5).
  2. Disassemble the Connector: Unscrew the cable gland nut and remove the sealing components from the main connector body.
  3. Kabloyu Geçirin: Pass the prepared cable through the cable gland nut and the sealing components in the correct order.
  4. Kabloları Bağlayın: Insert the stripped ends of the conductors into the designated screw terminals of the connector insert. Ensure correct polarity (Line, Neutral, Ground). The terminal markings are clear. Tighten the small clamping screws carefully to secure the wires.
  5. Assemble the Connector: Position the sealing gasket correctly around the connector insert. Insert the wired connector insert into the main connector body.
  6. Secure the Cable Gland: Screw the cable gland nut onto the connector body. Tighten it firmly to ensure a watertight seal (IP68 rating) and proper strain relief. The fit should be snug to maintain the protection degree.
  7. Connect to Micro-inverter: Align the assembled field connector with the AC port of your Hoymiles HMS series micro-inverter. Push firmly until it clicks into place, ensuring a secure and tight connection.

Note: The connector is designed for a tight fit to ensure its IP68 rating. Do not force it if misaligned.

6. Operasyon

Once properly installed, the Hoymiles HMS Field Connector BC05 operates passively by providing a continuous and secure electrical pathway between the micro-inverter and the AC grid. No user interaction is required for its operation. Ensure the connection remains tight and free from external damage.

7. Bakım

The Hoymiles HMS Field Connector BC05 is designed for minimal maintenance due to its robust construction and IP68 rating. However, periodic checks are recommended to ensure long-term reliability:

8. Sorun Giderme

If you encounter issues with your Hoymiles HMS Field Connector BC05, consider the following:

For issues not resolved by these steps, contact Hoymiles customer support or a qualified electrician.

9. Garanti ve Destek

For detailed warranty information and customer support, please refer to the official Hoymiles website or contact your local distributor. Warranty terms typically cover manufacturing defects under normal use conditions.

Üretici: Hoymiles / Betterie

Model Numarası: BC05-BR3M-02

10. Ek Kaynaklar

For more information, technical documents, and support, please visit the official Hoymiles webalan:

Hoymiles HMS Field Connector BC05 Product Page

QR code to Hoymiles website for HMS Field Connector

Şekil 10.1: Scan this QR code to access the Hoymiles website for more information on the HMS Field Connector.