ALLmeter B0C4SRMFMD

ALLmeter Pen Type Digital Multimeter AC Voltage Tester (Model B0C4SRMFMD) Instruction Manual

1. Giriş

This manual provides detailed instructions for the safe and effective use of your ALLmeter Pen Type Digital Multimeter, Model B0C4SRMFMD. This device is designed for measuring AC/DC voltage, resistance, diode, and continuity. It also features non-contact voltage (NCV) detection and live wire identification. Please read this manual thoroughly before operation and retain it for future reference.

2. Güvenlik Bilgileri

WARNING: Electrical shock hazard. Improper use of this meter can cause injury or death. Follow all safety precautions.

  • Always ensure the meter is in good working condition before use. Inspect for any damage to the casing or test leads.
  • Hacmi ölçmeye çalışmayıntagBelirtilen azami limitleri aşan akımlar veya akımlar.
  • Exercise extreme caution when working with live circuits. Always assume circuits are live until verified otherwise.
  • Wear appropriate personal protective equipment (PPE), such as safety glasses and insulated gloves.
  • Do not use the meter in wet environments or if your hands are wet.
  • Çalıştırmadan önce pil bölmesinin güvenli bir şekilde kapatıldığından emin olun.
  • Bu cihaz AC voltaj için tasarlanmıştır.tage detection in NCV mode and cannot measure DC current.

3. Ürün Bittiview

Familiarize yourself with the components of your ALLmeter Pen Type Digital Multimeter:

Diagram of ALLmeter Pen Type Digital Multimeter with labeled parts

Şekil 3.1: Labeled diagram of the ALLmeter Pen Type Digital Multimeter. Key components include the Input COM, Portable pen hook, Select key, HOLD key, N/L/P key, Display LCD, Signal strength indicator, LED light, and Test pen tip.

4. Kurulum

4.1 Pil Kurulumu

The ALLmeter Pen Type Digital Multimeter requires one AAA battery (included). To install or replace the battery:

  1. Locate the battery compartment cover, typically at the rear or top of the device.
  2. Kapağı açın.
  3. Bir adet AAA pili, doğru kutuplara (+/-) dikkat ederek takın.
  4. Pil bölmesi kapağını sıkıca kapatın.

The device includes a low-battery indicator on the LCD display to signal when replacement is needed.

5. Kullanım Talimatları

5.1 Güç Açma/Kapatma

Press the 'Select' button to power on the device. The device will automatically power off after 15 minutes of inactivity to conserve battery life.

5.2 Automatic Measurement Function

In automatic mode, the meter intelligently detects the type of measurement (DC/AC voltage or resistance) and displays the value. This simplifies the measurement process by eliminating the need to manually select ranges.

LCD display showing automatic AC, DC voltage, and resistance measurements

Şekil 5.1: Examples of automatic measurement displays for AC voltage, DC hacimtage, and resistance (Ohm).

5.3 Manual Functions (Electric Field and Live Wire Detection)

Pressing the 'N/L' button cycles through additional functions. Note that in these modes, only AC can be measured, not DC.

LCD display showing EF for Electric Fields and LIVE for live wire detection

Şekil 5.2: Displays for Electric Field (EF) and Live Wire (LIVE) detection modes.

  • EF (Electric Fields): This mode detects electric fields without requiring a ground wire. Bring the tip close to a wire to detect if it is live.
  • LIVE (Live Wire): In this mode, the device functions as an AC detector. Touch the tip to a wire, and it will beep if the wire is live.

5.4 Diyot Ölçümü

To measure a diode:

  1. Press the 'Select' button repeatedly until the diode symbol appears on the screen.
  2. Connect the test leads to the diode.
Hand holding the multimeter to measure a diode on a circuit board

Şekil 5.3: Measuring a diode on a circuit board using the multimeter.

5.5 Süreklilik Testi

The continuity test checks for an unbroken path in a circuit. If a continuous path is detected, the meter will emit an audible beep.

5.6 Temassız Hacimtage (NCV) Tespiti

The NCV feature allows for safe detection of AC voltage without direct contact. The device will indicate the presence of AC voltage within a range of 12V-1000V. In NCV mode, it can only detect alternating current (AC) and cannot measure direct current (DC).

Multimeter being used for non-contact voltage detection in a dimly lit electrical panel, with its LED light on

Şekil 5.4: Using the NCV function and LED light in a low-light environment.

5.7 Data Hold (HOLD Key)

Ekrandaki mevcut okumayı dondurmak için 'HOLD' düğmesine basın. Hold fonksiyonunu iptal etmek için tekrar basın.

5.8 LED el feneri

The built-in LED light can be activated to illuminate dimly lit work areas. Refer to the product overview for the location of the LED light.

6. Uygulamalar

The ALLmeter Pen Type Digital Multimeter is suitable for various electrical testing scenarios:

Two images: top shows testing an electrical outlet, bottom shows testing a circuit breaker panel

Şekil 6.1: Examples of multi-function usage, including testing electrical outlets and circuit breaker panels.

Hand using the multimeter to test components in a car engine bay

Şekil 6.2: Testing electrical components within a car engine.

7. Özellikler

ÖzellikŞartname
ÖrnekB0C4SRMFMD
GörüntülemekLCD, 6000 Counts
AC/DC Hacmitage AralıkAutomatic scanning test (DC/AC 6V, 60V, 600V)
Direnç Aralığı6kΩ, 60kΩ, 600kΩ, 6MΩ, 60MΩ
Temassız Hacimtage (NCV) Tespiti12V-1000V AC
Güç Kaynağı1 x AAA Pil (dahil)
Otomatik Kapanma15 dakika hareketsizlik
Boyutlar8.11 x 2.24 x 1.34 inç
Ağırlık4.23 ons
RenkSiyah

8. Bakım

  • Temizlik: Wipe the meter with a dry, soft cloth. Do not use abrasive cleaners or solvents.
  • Depolamak: When not in use for extended periods, remove the battery to prevent leakage. Store the meter in a cool, dry place, away from direct sunlight and extreme temperatures.
  • Pil Değişimi: Replace the AAA battery when the low-battery indicator appears on the display.

9. Sorun Giderme

SorunOlası NedenÇözüm
Sayaç açılmıyorBitmiş veya yanlış takılmış pilPil kutuplarını kontrol edin veya yeni bir AAA pille değiştirin.
Yanlış okumalarLow battery; incorrect mode selection; environmental interferenceReplace battery; ensure correct mode is selected; move away from strong electromagnetic fields.
NCV mode not detecting DCNCV mode is designed for AC onlyThis is normal operation. The NCV mode only detects alternating current (AC).
Display shows 'OL'Overload or open circuitThe measured value exceeds the range, or there is no connection. Check the circuit or range.

10. Paket İçeriği

The ALLmeter Pen Type Digital Multimeter package includes:

  • ALLmeter Pen Type Digital Multimeter
  • 1.5V AAA Batarya
  • Test Lideri
Image of the test lead included with the multimeter

Şekil 10.1: The included test lead for various measurements.

11. Garanti ve Destek

For warranty information or technical support, please refer to the documentation provided with your purchase or contact ALLmeter customer service directly. Contact details are typically available on the manufacturer's official website veya ürün ambalajı.

İlgili Belgeler - B0C4SRMFMD

Önview ALLmeter 6000 Sayım Kalem Tipi Akıllı Multimetre Kullanım Kılavuzu
ALLmeter 6000 Counts kalem tipi akıllı multimetre için kullanım kılavuzu.view, güvenlik önlemleri, genel ve teknik özellikler, çalışma paneli açıklaması, DCV/ACV için teknik göstergeler, direnç ve diyot ölçümleri, sorun giderme ve garanti bilgileri.
Önview Pinsiz Endüktif Nem Ölçer Kullanım Kılavuzu
Duvarlarda, duvarlarda, yumuşak ve sert ağaçlarda nem içeriğini ölçmek için kullanılan invaziv olmayan bir cihaz olan ALLmeter Pinsiz Endüktif Nem Ölçer'in talimatları ve teknik özellikleri. Özellikleri, teknik özellikleri, doğruluğu, çalışma şekli ve ahşap yoğunluk tablolarını içerir.