Opengear CM8116

Opengear CM8100 Console Server User Manual

Modeli: CM8116

giriiş

This manual provides instructions for the installation, operation, and maintenance of the Opengear CM8100 Console Server. The CM8100 series is designed to provide secure out-of-band management for network and server infrastructure, enabling remote access and control even during primary network outagee.

Key features of the CM8100 Console Server include:

  • 16, 32, or 48 port serial console server with Smart Out-of-Band™ capabilities.
  • Support for Data Center and Enterprise Network automation with Python and Docker.
  • Embedded physical security via TPM 2.0 module.
  • Dual power supplies for redundancy and independent monitoring.
  • Integrated environmental temperature monitoring.

Kurulum ve Yükleme

This section guides you through the physical installation and initial setup of your CM8100 Console Server.

Cihazın Paketini Açma

Carefully unpack all components from the box. Verify that all items listed in the "What's in the Box" section are present and undamaged.

Opengear CM8100 Console Server front view

Resim: Ön view of the Opengear CM8100 Console Server, showing the red and black chassis, Opengear logo, model number, and dual power inlets on the right side.

Raf Montajı

The CM8100 Console Server is designed for standard 19-inch rack installation.

  1. Attach the two rack ears to the sides of the console server using the provided M4 screws.
  2. Secure the console server into the rack using the four M5x15mm rack screws and M5mm caged nuts. Ensure the device is level and securely fastened.

Güç Bağlantısı

The CM8100 features dual power supplies for redundancy.

  1. Connect the two A/C power cables to the power inlets on the rear of the console server.
  2. Connect the other ends of the power cables to independent power sources for redundancy.
  3. Verify that the power indicator LEDs on the front panel illuminate, indicating successful power-up.

Ağ Bağlantısı

Connect the console server to your network for management access.

  1. Connect an Ethernet cable from your network switch to the primary network port on the console server.
  2. (Optional) Connect a second Ethernet cable to the secondary network port for network redundancy.

Seri Bağlantı Noktası Bağlantısı

Connect your managed devices (servers, network devices) to the serial ports on the CM8100.

  1. Identify the serial ports on the rear of the console server.
  2. Use appropriate serial cables (e.g., the provided CAT5 patch cable with DB9F-RJ45 rollover serial adapter) to connect your devices to the CM8100 serial ports.
  3. Note the port numbers for future configuration.
Arka view of Opengear CM8100 Console Server showing network and serial ports

Resim: Arka view of the Opengear CM8100 Console Server, displaying various network and serial console ports, along with dual power supply connections.

Operasyon

This section covers basic operation and initial access to the CM8100 Console Server.

İlk Erişim

Access the console server for initial configuration via a direct serial connection or network connection.

Serial Console Access

  1. Connect a computer to the console server's dedicated console port using a serial cable.
  2. Terminal öykünme yazılımınızı (örneğin, PuTTY, Tera Term) aşağıdaki ayarlarla yapılandırın: 115200 baud, 8 veri biti, eşliksiz, 1 durdurma biti, akış kontrolü yok.
  3. Power on the CM8100. The boot process will display on your terminal.
  4. Varsayılan kimlik bilgilerini kullanarak giriş yapın (varsayılan kullanıcı adı ve şifre için Hızlı Başlangıç ​​Kılavuzuna bakın).

Network Access (Web Arayüz)

Once the device has an IP address (either DHCP assigned or manually configured via serial console), you can access the web arayüz.

  1. Bir tane aç web browser and enter the IP address of the CM8100.
  2. Kullanıcı adınızı kullanarak giriş yapın.
  3. Şuradan: web interface, you can configure serial ports, network settings, user accounts, and other system parameters.

Bağlı Cihazları Yönetme

The CM8100 allows you to connect to the console of your attached devices.

  • Serial Console Access: Şuradan: web interface or command-line interface (CLI), select the desired serial port to establish a connection to the attached device.
  • Grup Dışı Yönetim: Utilize the Smart OOB™ features to access and manage devices even when the primary network is down.

Bakım

Regular maintenance ensures optimal performance and longevity of your CM8100 Console Server.

Firmware güncellemeleri

Periodically check the Opengear website for firmware updates. Keeping the firmware current provides new features, bug fixes, and security enhancements.

  1. Download the latest firmware image from the official Opengear support portal.
  2. Access the CM8100 web arayüz.
  3. Navigate to the firmware update section (typically under System > Firmware).
  4. Follow the on-screen instructions to upload and install the new firmware. Do not power off the device during the update process.

Temizlik

Keep the console server clean to prevent dust buildup, which can affect cooling.

  • Cihazın dışını silmek için yumuşak ve kuru bir bez kullanın.
  • Havalandırma açıklıklarının engellerden arındırılmış olduğundan emin olun.
  • Do not use liquid cleaners directly on the device.

Çevresel Hususlar

Ensure the operating environment meets the recommended conditions.

  • Maintain proper airflow around the device.
  • Keep the device within specified temperature and humidity ranges.

Sorun giderme

This section provides solutions to common issues you might encounter with the CM8100 Console Server.

Güç Yok

  • semptom: Power indicator LEDs are off, device does not respond.
  • Çözüm: Verify that both A/C power cables are securely connected to the device and to active power outlets. Check power sources and circuit breakers.

Erişilemiyor Web Arayüz

  • semptom: Web browser cannot connect to the CM8100 IP address.
  • Çözüm:
    1. Verify the console server has power and is running.
    2. Confirm the network cable is properly connected to an active network port.
    3. Check the IP address configuration of the CM8100 (via serial console if necessary).
    4. Ensure your computer is on the same network or has a route to the CM8100's IP address.
    5. Temporarily disable any firewalls on your computer to rule out interference.

No Serial Console Connection to Managed Device

  • semptom: Unable to establish a serial connection to a device connected to the CM8100.
  • Çözüm:
    1. Verify the serial cable connection between the CM8100 port and the managed device.
    2. Ensure the correct serial cable type (e.g., rollover, straight-through) is used for the specific device.
    3. Check the serial port configuration on the CM8100 (baud rate, data bits, parity, stop bits, flow control) matches the settings of the managed device.
    4. Confirm the managed device is powered on and functioning correctly.

Özellikler

Özellik Detay
Marka Opengear
Seri CM8100 Console Server
Model Numarası CM8116
Ürün Ağırlığı 8.63 pound
Ürün Boyutları (UxGxY) 19.5 x 16.5 x 3.5 inç
Üretici Opengear
İlk Mevcut 16 Şubat 2023

Kutuda Neler Var?

The following items are included with your Opengear CM8100 Console Server:

  • CM8100 Console Server
  • Raf Montaj Seti
  • 2 x Rack Ears with Six M4 Screws
  • 4 x M5mm Caged Nuts
  • 4 x M5x15mm Rack Screws
  • 1 x CAT5 Patch Cable 6'
  • 1 x DB9F-RJ45 Rollover Serial Adapter
  • 2 x A/C Power Cables
  • Hızlı Başlangıç ​​Kılavuzu
  • Lighthouse Insert

İlgili Belgeler - CM8116

Önview Opengear CM8100 Console Manager Quick Start Guide
This guide provides instructions for the basic installation and configuration of the Opengear CM8100 Console Manager, including models CM8116, CM8132, and CM8148. Learn how to connect network and serial devices, access the web UI, and configure essential settings.
Önview Opengear Console Manager 25.11 User Guide
This comprehensive user guide provides detailed instructions for installing, configuring, and managing the Opengear Console Manager 25.11. It covers essential features for IT infrastructure, including network connectivity, security settings, system alerts, and advanced operational capabilities.
Önview Opengear Console Manager 25.11 User Guide
Comprehensive user guide for the Opengear Console Manager 25.11, detailing installation, configuration, network management, security features, and advanced options for IT infrastructure.
Önview Opengear Console Manager User Guide Software Release 24.03.0
Comprehensive user guide for the Opengear Console Manager, detailing installation, configuration, CLI operations, network settings, security features, and troubleshooting for software release 24.03.0.
Önview Opengear Console Manager 25.11 User Guide - Installation, Configuration, and Operation
This user guide provides comprehensive instructions for installing, configuring, and operating the Opengear Console Manager 25.11, covering features like network connectivity, user management, security, and advanced options.
Önview OpenGear Konsol Sunucusu Kullanıcı Kılavuzu
Comprehensive user guide for Opengear Console Servers, including ACM7000, ACM7000-L, IM7200, and CM7100 models. Covers installation, configuration, management, and advanced features for IT infrastructure.