giriiş
This manual provides essential information for the safe and effective operation of your Hughes Autoformers RV2130SP Voltage Booster with Surge Protection. This device is designed to protect your RV's electrical system from low voltage conditions and power surges, ensuring optimal performance and longevity of your appliances.
Kutuda Neler Var?
- Hughes Autoformers RV2130SP Voltage Booster with Surge Protection - 30 Amp Birim
Güvenlik Bilgileri
Read all instructions carefully before use. Failure to do so may result in property damage, electrical shock, or serious injury. Always prioritize safety when handling electrical equipment.
- Always ensure the power pedestal's circuit breaker is in the "OFF" position before connecting or disconnecting the unit.
- Do not operate the unit if it appears damaged or if the casing tehlikeye girdi.
- Keep the unit dry and away from water. While designed for outdoor use, protect it from direct heavy rain or submersion.
- Ensure proper grounding at the power source. The unit's diagnostic LEDs will indicate grounding issues.
- Do not attempt to open or repair the unit yourself, except for replacing the surge module as instructed in the Maintenance section.
- Use only with 30 Amp RV electrical systems.
Temel Özellikler
- Tam otomatik %10 hacimtage boost when input voltage drops to 113V or below.
- 2% hacimtage boost in standby mode (when incoming voltage is 114V or higher).
- Complete LED park power diagnostics for easy status monitoring of Line Power, Ground, and Neutral.
- Dedicated boost indicator light to confirm active voltage boosting.
- Integrated 2,400 Joules of advanced surge protection.
- User-replaceable surge/spike protection module for extended unit life.
- Includes security lock for theft deterrence.
Kurulum ve Bağlantı
Follow these steps to properly connect your RV2130SP unit to the RV park's power pedestal and your RV.
- Güç ünitesini inceleyin: Before connecting, visually inspect the RV park's power pedestal for any visible damage or signs of wear. Ensure the circuit breaker for the 30 Amp outlet is in the "OFF" position.
- Connect the RV2130SP Input: Plug the male end of the RV2130SP's power cord into the 30 Amp outlet on the RV park's power pedestal. Ensure a secure connection.
- Connect Your RV to RV2130SP Output: Plug your RV's 30 Amp shore power cord into the female receptacle on the RV2130SP unit.
- Gücü Etkinleştir: Once both connections are secure, switch the circuit breaker on the RV park's power pedestal to the "ON" position.
- İşlemi Doğrulayın: Observe the LED indicators on the RV2130SP unit to confirm proper power and boosting status. Refer to the "Operation and LED Indicators" section for details.

Image: The input power cord of the RV2130SP, designed to connect to the RV park's power pedestal.

Image: The output power receptacle on the RV2130SP, where your RV's shore power cord connects.

Resim: Ayrıntılı view 30'in Amp, 125 Volt RV receptacle on the unit, showing its specifications and UL listing.

Image: The Hughes Autoformers RV2130SP unit, displaying its front panel with LED indicators and product labeling.
Operation and LED Indicators
The RV2130SP features a diagnostic panel with LED lights to indicate the status of the incoming power and the unit's operation. Understanding these indicators is crucial for safe and effective use.
LED Light Indication Guide
| Işık | Durum | Tanım |
|---|---|---|
| Hat Gücü | Yeşil AÇIK | Indicates incoming power is present. |
| Zemin | Yeşil AÇIK | Indicates proper ground connection. |
| Doğal | Yeşil AÇIK | Indicates proper neutral connection. |
| Güçlendirme | Yeşil AÇIK | Unit is actively boosting voltage due to low incoming power. |
| Surge Capacity Used Up | Kırmızı AÇIK | Surge protection module has absorbed a significant surge and needs replacement. |
| Hot / Ground / Surge | Kırmızı AÇIK | Indicates a hot/ground fault or a major surge event. |
| Hot / Neutral / Surge | Kırmızı AÇIK | Indicates a hot/neutral fault or a major surge event. |
| Eksik Zemin | Kırmızı AÇIK | Indicates the power pedestal has no ground connection. |
| Ters kutup | Kırmızı AÇIK | Indicates hot and neutral wires are reversed at the pedestal. |
| Missing Neutral | Kırmızı AÇIK | Indicates the power pedestal has no neutral connection. |
Otomatik Sestage Boosting
The RV2130SP automatically monitors incoming voltage. Eğer cilttage drops to 113 Volts or below, the unit will automatically engage its boosting function, increasing cilttage by 10%. If the incoming voltage is 114 Volts or higher, the unit will provide a 2% boost to maintain optimal power delivery to your RV.
Bakım
Surge Module Replacement
The RV2130SP features a replaceable surge protection module. If the "Surge Capacity Used Up" (Red) LED illuminates, it indicates that the surge module has absorbed a significant power surge and needs to be replaced to ensure continued surge protection for your RV.
To Replace the Surge Module:
- Disconnect the RV2130SP from all power sources (both your RV and the power pedestal).
- Locate the surge module access panel on the unit (refer to your product's physical diagram if unsure).
- Carefully remove the screws securing the access panel.
- Disconnect the old surge module from its connectors.
- Connect the new surge module, ensuring proper orientation and secure connections.
- Securely reattach the access panel with the screws.
- Reconnect the RV2130SP to power and verify that the "Surge Capacity Used Up" light is now off.
For replacement parts, contact Hughes Autoformers customer support.
Sorun giderme
Use the LED indicators on the unit to diagnose common issues. If a problem persists, contact customer support.
| Sorun | Indication (LEDs) | Olası Neden | Çözüm |
|---|---|---|---|
| No Power to RV | Hiçbir LED yanmıyor | No power from pedestal; Unit not connected; RV breaker tripped. | Check pedestal breaker; Ensure unit is fully plugged in; Check RV's main breaker. |
| Düşük Hacimtage Koşul | Boosting LED ON (and other power LEDs green) | gelen cilttage 114V'un altındadır. | This is normal operation. The unit is boosting power. No action required unless voltage remains critically low after boosting. |
| Surge Protection Activated | Surge Capacity Used Up (Red) LED ON | Unit absorbed a large power surge. | Replace the surge protection module as described in the Maintenance section. |
| Wiring Fault at Pedestal | Missing Ground (Red) OR Reverse Polarity (Red) OR Missing Neutral (Red) OR Hot/Ground/Surge (Red) OR Hot/Neutral/Surge (Red) | Faulty or unsafe wiring at the power pedestal. | Immediately disconnect the unit. Do NOT connect your RV. Notify park management of the wiring issue. |
| Unit Not Boosting | Boosting LED OFF, but voltage düşüktür. | Unit malfunction or voltage is not low enough to trigger 10% boost. | Ensure incoming voltage is below 114V. If still not boosting, contact customer support. |
Teknik Özellikler
| Özellik | Detay |
|---|---|
| Örnek | RV2130SP |
| Ampöfke | 30 Amps |
| Cilttage | 114 Volt (Nominal) |
| Aşırı Gerilim Koruması | 2,400 Joules (Replaceable Module) |
| Cilttage Güçlendirme | 10% (when < 114V), 2% (when ≥ 114V) |
| Ürün Ağırlığı | 21.7 pound |
| Paket Boyutları | 15 x 10.6 x 10.3 inç |
| Özel Özellikler | Surge Protection, LED Diagnostics, Security Lock |
| Üretici | Hughes Otomatik Şekillendiriciler |
| Marka | Güç Gözlemcisi |
Garanti ve Müşteri Desteği
For detailed warranty information, technical assistance, or to purchase replacement parts such as the surge protection module, please contact Hughes Autoformers customer support directly.
İletişim Bilgileri:
Please refer to the product packaging or the official Hughes Autoformers webEn güncel iletişim bilgileri, telefon numaraları ve e-posta adresleri için siteyi ziyaret edin.
Çevrimiçi Kaynaklar:
Ziyaret edin Power Watchdog Store on Amazon for additional product information, accessories, and customer reviews.