APEX Domus 3

Apex Medical Domus 3 Alternatif Basınçlı Yatak Sistemi Kullanım Kılavuzu

Model: Domus 3

1. Giriş

This manual provides comprehensive instructions for the safe and effective use of the Apex Medical Domus 3 Alternating Pressure Mattress System. This system is designed to assist in the prevention and treatment of pressure injuries, ulcers, and bedsores for individuals requiring extended bed rest. Please read this manual thoroughly before setup and operation.

Apex Medical Domus 3 Alternating Pressure Mattress System with pump on a hospital bed.

Şekil 1.1: The Apex Medical Domus 3 Alternating Pressure Mattress System. This image displays the complete system, including the mattress installed on a hospital bed frame and the external pump unit. The mattress features individual air cells, and the pump is shown connected to the mattress.

2. Güvenlik Bilgileri

Adherence to the following safety guidelines is crucial for patient well-being and proper system function.

3. Bileşenler

The Apex Medical Domus 3 system typically includes the following components:

4. Kurulum Talimatları

  1. Yatak çerçevesini hazırlayın: Place the mattress system directly onto a standard hospital or home bed frame. Ensure the bed frame is clean and free of sharp objects that could damage the mattress.
  2. Yatağı doğru şekilde yerleştirin: Unroll the Domus 3 mattress on the bed frame with the air hose connection end positioned towards the foot of the bed where the pump will be placed. Ensure the CPR strap is accessible.
  3. Pompayı bağlayın: Attach the air hoses from the mattress to the corresponding connectors on the variable pressure pump unit. Ensure connections are secure.
  4. Mount the Pump: Hang the pump unit securely at the foot of the bed using its integrated hangers.
  5. Gücü bağlayın: Plug the pump's power cord into a grounded electrical outlet.
  6. Initial Inflation: Turn on the pump. The mattress will begin to inflate. Allow approximately 20-30 minutes for the mattress to fully inflate and stabilize before placing a patient on it.
Apex Medical Domus 3 mattress cover with zipper and water-resistant material detail.

Şekil 4.1: Mattress Cover Features. An image showcasing two features of the mattress cover: a close-up of the zipper-all-around design for easy removal and replacement, and a magnified view of the Nylon/PU cover material demonstrating its water-resistant properties with water droplets on the surface.

5. Kullanım Talimatları

5.1 Güç Açma/Kapatma

5.2 Therapy Modes

The Domus 3 offers two therapy modes:

Refer to the pump unit's controls to select the desired therapy mode.

Diagram illustrating the alternating pressure redistribution cycle of the mattress.

Şekil 5.1: Alternating Pressure Cycle. This diagram shows a human figure lying on the mattress, with an illustration of the alternating pressure cycle. Blue blocks represent inflated air cells, and arrows indicate the cyclical inflation and deflation pattern designed to redistribute pressure and prevent injury.

5.3 Pressure Adjustment (Firmness)

The pump unit features a variable pressure setting with a weight indicator.

5.4 Low Air Loss Function

Air cells 3 through 11 are designed with a low air loss feature. This function continuously ventilates air to wick moisture and heat away from the mattress surface, contributing to patient comfort and skin integrity. This operates automatically when the system is powered on.

Close-up of Apex Medical Domus 3 mattress showing low air loss ventilation.

Şekil 5.2: Low Air Loss Feature. A detailed view of the mattress surface, highlighting the low air loss feature. Blue arrows indicate airflow through the air cells, designed to reduce moisture and heat for patient comfort and prevent skin maceration.

6. Bakım ve Özen

6.1 Cleaning the Mattress and Cover

6.2 Air Cell Replacement

Each of the 20 individual 8-inch air cells can be removed and replaced if damaged.

  1. Turn off the pump and disconnect it from the mattress.
  2. Unzip the mattress cover.
  3. Carefully detach the damaged air cell from its connections within the mattress structure.
  4. Install a new, compatible air cell, ensuring it is securely connected.
  5. Zip the mattress cover back into place and re-connect the pump for inflation.

7. Sorun Giderme

SorunOlası NedenÇözüm
Mattress not inflating or losing pressure
  • Güç kablosunun bağlantısı kesildi
  • Air hoses not securely connected
  • Leak in mattress or air cells
  • Pompa arızası
  • Check power connection to outlet and pump.
  • Ensure air hoses are firmly attached to both mattress and pump.
  • Inspect mattress and individual air cells for punctures or damage. Replace damaged cells if necessary.
  • Contact customer support if pump appears to be malfunctioning.
Low pressure alarm sounds
  • Mattress not fully inflated
  • Hava kaçağı
  • Patient weight exceeds capacity
  • Allow more time for inflation.
  • Check for leaks in mattress or hose connections.
  • Verify patient weight is within the 440 lbs capacity.
Pump is unusually loud
  • Obstruction around pump fan
  • Pompa arızası
  • Ensure adequate ventilation around the pump unit.
  • Contact customer support if noise persists. (Note: Pump noise level is typically ≤ 30dB(A)).

8. Özellikler

ÖzellikDetay
ÖrnekEv 3
Mattress Dimensions (L x W x H)78.7 x 35.4 x 8 inç
Sistem AğırlığıYaklaşık 22.3 Pound
Ağırlık Kapasitesi440 pound
Kumaş TürüNylon, Polyurethane (Cover)
Özel ÖzelliklerLow Air Loss, Alternating Pressure, Water Resistant Cover, CPR Strap, Low Pressure Alarm
Pompa Gürültü Seviyesi≤ 30dB (A)
ÜreticiApex Medikal
Dimensions of Apex Medical Domus 3 mattress and pump system.

Şekil 8.1: System Dimensions. A visual representation of the dimensions for both the Apex Medical Domus 3 mattress and its accompanying pump unit. Key measurements for length, width, and height are indicated for both components.

Apex Medical Domus mattress showing two height options, 5-inch and 8-inch.

Şekil 8.2: Mattress Height Options. This image illustrates the two available height options for the Domus mattress: a 5-inch version and an 8-inch version. The current product is the 8-inch model, providing enhanced support.

9. Garanti ve Destek

9.1 Garanti Bilgileri

The Apex Medical Domus 3 Alternating Pressure Mattress System comes with a 1 yıl garanti on both the mattress and the pump unit. This warranty covers manufacturing defects and malfunctions under normal use. Please retain your proof of purchase for warranty claims.

9.2 Müşteri Desteği

For technical assistance, troubleshooting beyond this manual, or warranty inquiries, please contact Apex Medical customer support. Refer to the product packaging or the official Apex Medical webGüncel iletişim bilgileri için siteyi ziyaret edin.

İlgili Belgeler - Ev 3

Önview APEX XT Auto Provider Mode Quick Guide
A quick guide for medical professionals on how to use the APEX XT Auto device in Provider Mode, including setup navigation and resetting compliance meters.
Önview APEX VAC Pompası Kullanım Kılavuzu: Talimatlar ve Güvenlik Kılavuzu
Apex Medical Corp.'un VacPro, VacMaxi ve VacPlus modelleri için APEX VAC Pompası için kapsamlı kullanıcı kılavuzu, çalıştırma, güvenlik, teknik özellikler ve sorun giderme ayrıntılarını içerir.
Önview APEX XT Otomatik CPAP Sistemi Kullanım Kılavuzu
APEX XT Otomatik CPAP Sistemi (Model 9S-005720) için kapsamlı kullanım kılavuzu, Obstrüktif Uyku Apnesi (OSA) tedavisi için kurulum, çalıştırma, bakım, sorun giderme ve teknik özellikleri ayrıntılı olarak açıklamaktadır.
Önview APEX-V2 Masaj Koltuğu Kullanım Kılavuzu - Kurulum, Çalıştırma ve Bakım Rehberi
APEX-V2 masaj koltuğu için kapsamlı kullanım kılavuzu; güvenlik önlemleri, kurulum, çalıştırma, ayarlar, teknik özellikler, sorun giderme, temizlik ve bakım konularını kapsamaktadır. APEX-V2 masaj koltuğunuzu etkili bir şekilde nasıl kuracağınızı ve kullanacağınızı öğrenin.
Önview DESTINY Güvenlik Sistemi Kullanım Kılavuzu
Apex DESTINY Güvenlik Sistemi için bu kullanıcı kılavuzu, kurulum, çalıştırma, kurma modları (UZAK, EV, GECE), uzaktan erişim, baypas işlevleri ve isteğe bağlı ev otomasyonu özellikleri hakkında kapsamlı rehberlik sağlar.
Önview Apex AP-Pomp Masaj Koltuğu Kullanım Kılavuzu
Apex AP-Pomp masaj koltuğu için kapsamlı kullanıcı kullanım kılavuzu; güvenlik önlemleri, bakım, kurulum, kumanda fonksiyonları, sorun giderme ve teknik özellikler konularını kapsamaktadır.