Waveshare Modbus RTU Relay

Waveshare Endüstriyel Modbus RTU 8 Kanallı Röle Modülü Kullanım Kılavuzu

Model: Modbus RTU Relay

1. Giriş

This manual provides detailed instructions for the Waveshare Industrial Modbus RTU 8-Channel Relay Module. This module is designed for industrial control applications, offering reliable relay switching via an RS485 interface using the Modbus RTU protocol. It features multiple isolation protection circuits for enhanced safety and stability.

Temel özellikler şunlardır:

  • Configurable device address (1-255) for multi-device cascading on an RS485 bus.
  • Flash-on, flash-off function for timed relay activation.
  • Onboard unibody power supply isolation for stable isolated voltage.
  • Onboard unibody magnetic isolation for signal integrity, high reliability, and strong anti-interference.
  • Yerleşik TV'ler (Geçici Hacimtage Suppressor) for surge and transient spike voltage suppression, providing lightning protection and anti-electrostatic capabilities.
  • Onboard optocoupler isolation to prevent interference from external high-voltage devreler.
  • Reverse-proof circuit to protect against accidental damage from incorrect power connection.
  • High-quality relays with a contact rating of ≤10A 250VAC/30VDC.
  • Rail-mounted ABS plastic enclosure for easy installation and safe use.
  • Three LEDs indicating MCU status and signal transceiving status.

2. Paket İçeriği

The standard package for the Waveshare Industrial Modbus RTU 8-Channel Relay Module includes the following items:

  • Waveshare Modbus RTU 8-Channel Relay Module
  • Power adapter (may vary by region)
Package contents of the Waveshare Modbus RTU 8-Channel Relay Module

Image 2.1: The image displays the Waveshare Modbus RTU 8-Channel Relay Module along with a power adapter and a USB to RS485 converter (converter not included with the module).

3. Donanım Bittiview

The Modbus RTU 8-Channel Relay Module is designed with robust components and protection circuits. Understanding its internal structure is crucial for proper use and troubleshooting.

Internal hardware analysis of the Waveshare Modbus RTU 8-Channel Relay Module

Resim 3.1: Bu resim ayrıntılı bir bilgi sağlar view of the module's internal components, highlighting the high-quality relays, optocoupler isolation, magnetic signal isolation, power supply isolation, TVS lightning & ESD protection, and thickened tracks for large current.

3.1. Temel Bileşenler

  • High Quality Relay: Ensures reliable switching for connected devices.
  • Optocoupler Isolation: Provides electrical isolation between control and load circuits.
  • Magnetic Signal Isolation: Enhances signal integrity and anti-interference capabilities.
  • Güç Kaynağı İzolasyonu: Isolates the power supply for stability and safety.
  • TVS Lightning & ESD Protection: Volkanlara karşı koruma sağlar.tage surges and electrostatic discharge.
  • Thickened Track for Large Current: Designed to handle higher current loads safely.

3.2. Enclosure Design

The module is housed in a rail-mounted ABS plastic enclosure, facilitating easy installation in industrial environments and ensuring safe operation.

Rail-mounted ABS plastic enclosure design of the relay module

Image 3.2: The image shows the module's rail-mounted ABS plastic enclosure, designed for easy and secure installation.

4. Kurulum

Follow these steps to set up your Waveshare Industrial Modbus RTU 8-Channel Relay Module.

4.1. Güç Bağlantısı

  1. Connect the provided power adapter to the DC 5V input terminal of the relay module. Ensure the polarity is correct to prevent damage.
  2. Verify that the power LED indicator on the module illuminates, indicating successful power-on.

4.2. RS485 Communication Setup

The module communicates via RS485. Multiple devices can be cascaded on the RS485 bus. If communication distance is long, RS485 repeaters may be necessary.

  1. Connect the RS485 A+, B-, and GND terminals of the module to your RS485 master device (e.g., a computer with a USB to RS485 converter, or a PLC).
  2. Ensure correct wiring: A+ to A+, B- to B-, and GND to GND.
  3. For multiple modules, connect them in a daisy-chain configuration as shown in the diagram below.
RS485 communication wiring diagram for multiple relay modules

Image 4.1: This diagram illustrates how to connect multiple Modbus RTU relay modules in a daisy-chain configuration using an RS485 bus, typically connected to a USB to RS485 converter.

4.3. Device Address Configuration

Each module on the RS485 bus must have a unique device address, configurable from 1 to 255. Refer to the Modbus RTU protocol documentation for your specific software or controller to set the device address.

5. Kullanım Talimatları

The Waveshare Modbus RTU 8-Channel Relay Module operates using the standard Modbus RTU protocol over an RS485 interface. This section outlines how to control the relays.

5.1. Modbus RTU Protocol

The module responds to standard Modbus RTU commands. You will typically use Modbus function codes to read coil status, write single coils, or write multiple coils to control the relays. Consult the Modbus RTU specification for detailed command structures.

5.2. Relay Control

Each of the 8 channels corresponds to a relay. Relays can be individually controlled (turned ON/OFF) using Modbus commands. The module also supports a flash-on, flash-off function, allowing you to activate a relay for a specified duration and then automatically deactivate it.

5.3. LED Göstergeleri

  • STA (Durum) LED'i: Keeps flashing when the MCU is working normally.
  • TXD (Transmit) LED: Lights up when the module is sending data.
  • RXD (Receive) LED: Lights up when the module is receiving data.

6. Relay Connection

The module's relays have a contact rating of ≤10A 250VAC/30VDC. This allows direct control of various AC and DC devices. Always ensure that the connected load does not exceed the relay's maximum current and voltage derecelendirme.

6.1. AC 220V Device Connection

For connecting AC 220V devices, ensure proper insulation and safety precautions. Connect the AC load to the COM (Common) and NO (Normally Open) terminals of the desired relay channel.

6.2. DC 30V Device Connection

For connecting DC devices up to 30V, connect the DC load to the COM (Common) and NO (Normally Open) terminals of the desired relay channel. Ensure correct polarity for DC loads.

Relay connection diagrams for AC 220V and DC 30V devices

Image 6.1: This diagram illustrates how to connect both AC 220V and DC 30V devices to the relay module. It shows wiring for a light bulb (AC) and a motor (DC) using the COM and NO terminals, with the module powered by DC 5V.

7. Uygulamalar

The Waveshare Industrial Modbus RTU 8-Channel Relay Module is versatile and suitable for a wide range of applications:

  • Endüstriyel Kontrol: Valve control, pump station control, and unattended industrial control systems.
  • Akıllı Ev: Controlling appliances like air conditioners, access control systems, purifiers, and water heaters.
  • Intelligent Agriculture: Controlling door curtain motors, air blowers, and other agricultural equipment.
  • Breeding & Farming: Controlling ventilators, lighting, water supply systems, and feeding systems.
Various application scenarios for the relay module

Image 7.1: This image displays four common application areas for the relay module: Industrial Control, Smart Home, Intelligent Agriculture, and Breeding & Farming, showing examples of equipment that can be controlled.

8. Özellikler

Detailed technical specifications for the Modbus RTU Relay Module:

ÖzellikModbus RTU RelayModbus RTU Relay (B)
Güç Kaynağı5V7-36V
İletişim ArayüzüRS485
Baud hızı4800, 9600, 19200, 38400, 57600, 115200, 128000, 256000
Varsayılan İletişim Formatı9600, K, 8, 1
Röle Kanalları8
İletişim Formu1NA 1NK
İletişim Derecelendirmesi≤10A 250VAC/30VDC
İletişim ProtokolüStandart Modbus RTU protokolü
RS485 Adresi1-255
LED GöstergeleriSTA: MCU indicator, keeps flashing when the MCU normally working
TXD: TX indicator, lights up when sending data
RXD: RX indicator, lights up when receiving data

9. Bakım

The Waveshare Industrial Modbus RTU 8-Channel Relay Module is designed for robust and reliable operation with minimal maintenance. To ensure longevity and optimal performance:

  • Temiz tut: Periodically clean the exterior of the module with a soft, dry cloth. Avoid using harsh chemicals or abrasive materials.
  • Çevresel Koşullar: Operate the module within its specified temperature and humidity ranges. Avoid exposure to excessive dust, moisture, or corrosive environments.
  • Bağlantı Bütünlüğü: Regularly check all wiring connections (power, RS485, and relay loads) to ensure they are secure and free from corrosion or damage.
  • Donanım Yazılımı Güncellemeleri: Waveshare'in resmi sitesini kontrol edin. website for any available firmware updates that may improve performance or address issues. Follow update instructions carefully.

10. Sorun Giderme

If you encounter issues with your Waveshare Industrial Modbus RTU 8-Channel Relay Module, refer to the following troubleshooting tips:

  • Modül Açılmıyor:
    • Güç adaptörünün doğru şekilde bağlandığından ve belirtilen hacmi sağladığından emin olun.tage (Bu model için 5V).
    • Check the power outlet and cable for functionality.
    • Verify the power LED indicator. If it's off, there might be a power issue.
  • No RS485 Communication:
    • Verify RS485 wiring: A+ to A+, B- to B-, and GND to GND.
    • Check the baud rate, data bits, parity, and stop bits settings in your Modbus master software. These must match the module's default or configured settings (e.g., 9600, N, 8, 1).
    • Ensure the module's RS485 device address is unique and correctly configured in your master software.
    • Observe the TXD and RXD LEDs. If they are not flashing during communication attempts, check wiring and software settings.
    • For long distances or multiple devices, consider adding RS485 terminators or repeaters.
  • Röleler Aktif Değil:
    • Confirm that the module is powered on and communicating correctly (check communication LEDs).
    • Verify the Modbus commands sent to activate the specific relay channels.
    • Check the wiring of the load connected to the relay. Ensure the load's power supply is active and within the relay's contact rating.
    • Ensure the load itself is functional.
  • Aralıklı operasyon:
    • Check for loose connections on power, RS485, and relay terminals.
    • Ensure the operating environment is stable and free from excessive electrical noise or temperature fluctuations.
    • Verify that the power supply is stable and sufficient for both the module and the connected loads.

11. Anahat Boyutları

The physical dimensions of the Waveshare Industrial Modbus RTU 8-Channel Relay Module are provided below for installation planning.

Outline dimensions of the Waveshare Modbus RTU 8-Channel Relay Module

Image 11.1: This image provides detailed measurements of the module, including its length (145mm), width (90mm), and height (40mm), along with other specific dimensions for mounting.

12. Garanti ve Destek

Waveshare products are designed for quality and reliability. For specific warranty information, please refer to the warranty policy provided with your purchase or visit the official Waveshare website. For technical support, documentation, and additional resources, please visit the Waveshare support portal or contact their customer service directly.

Resmi Waveshare Webalan: www.waveshare.com

İlgili Belgeler - Modbus RTU Relay

Önview Modbus RTU Rölesi: Kullanım Kılavuzu ve Teknik Kılavuz
Modbus RTU Rölesi için kapsamlı bir kılavuz olup, güvenlik talimatlarını, donanım bağlantısını, SSCOM ve Modbus Poll ile yazılım kurulumunu ve çeşitli işlemler için ayrıntılı komut protokollerini kapsar.ampRaspberry Pi, STM32, Arduino ve PLC entegrasyonu için dosyalar.
Önview Modbus RTU Rölesi 32CH Kullanım Kılavuzu ve Teknik Kılavuz
Modbus RTU Rölesi 32CH için kapsamlı kullanıcı kılavuzu ve teknik rehber. Güvenlik, donanım, yazılım entegrasyonu (Raspberry Pi, STM32, Arduino, PLC) ve endüstriyel otomasyon için Modbus RTU komut protokollerini kapsar.
Önview Waveshare'in Analog Giriş Modülü Modbus RTU 8 Canaux
Bu belge tekniği, Waveshare'in 8 kanallı Modbus RTU analog giriş modülünü sunar ve endüstriyel otomasyon sistemlerinde gerilim verilerinin edinilmesi ve tavsiyelerde bulunulması için kullanılır. Ayrıntılı teknik özellikler, bağlantı yöntemleri, mantıksal testler ve Modbus iletişim protokolü.
Önview Modbus POE ETH Relay User Manual and Configuration Guide
Comprehensive guide for the Waveshare Modbus POE ETH Relay, covering hardware connection, safety instructions, parameter configuration using Vircom software and web interface, virtual serial port setup, and detailed Modbus RTU/TCP protocol commands and examples.
Önview Modbus RTU E/S 8CH: Industrial 8-Channel Digital Input/Output Module
Comprehensive technical guide for the Waveshare Modbus RTU E/S 8CH module, detailing its specifications, wiring, primary functions, testing procedures, and Modbus communication protocol for industrial automation applications.
Önview Waveshare Modbus RTU Analog Çıkış 8 Kanal - Teknik Kılavuz ve Protokol
Waveshare Modbus RTU Analog Çıkışlı 8CH modülü için kapsamlı teknik kılavuz. Donanım açıklamalarını, sürüm karşılaştırmalarını, donanım bağlantılarını, SSCOM ve Modbus Poll ile yazılım testlerini, Raspberry Pi, STM32, Arduino ve PLC için demo prosedürlerini ve ayrıntılı bir Modbus geliştirme protokolü olan V2'yi kapsar.