1. Giriş

This manual provides comprehensive instructions for the installation, operation, and maintenance of your Elkay LBWD00WHC Liv Recessed Bottle Filling Station. This built-in filtered water dispenser offers a hands-free water source, delivering cleaner, healthier water. Please read this manual thoroughly before installation and use to ensure proper function and safety.

Elkay Liv Recessed Bottle Filling Station in Aspen White

Figure 1: Elkay Liv Recessed Bottle Filling Station (Aspen White)

The Elkay Liv Recessed Bottle Filling Station features a sleek design with hands-free operation and an integrated filter. The unit is shown here in Aspen White.

2. Güvenlik Bilgileri

Yangın, elektrik çarpması veya kişilerin yaralanma riskini azaltmak için bu ürünü kurarken, çalıştırırken veya bakımını yaparken her zaman temel güvenlik önlemlerine uyun.

3. Kurulum ve Kurulum

Proper installation is crucial for the optimal performance and longevity of your Elkay Liv Bottle Filling Station. It is recommended that plumbing and electrical rough-ins be completed by licensed professionals.

3.1 Kurulum Öncesi Kontrol Listesi

3.2 Kurulum Adımları

  1. Kurulum Alanını Hazırlayın: Ensure the wall cavity is clear and ready for the unit.
  2. Üniteyi Monte Edin: Carefully place the main dispenser unit into the wall opening. Secure it to wall studs using appropriate fasteners. Use a level to ensure proper alignment.
  3. Elektrik Bağlantısı: Connect the 110V AC power supply to the unit's electrical gang box. All electrical work must comply with local codes.
  4. Install Filter Box: Position the filter box below the main unit, ensuring alignment. Secure it to the wall studs.
  5. Su Hatlarını Bağlayın: Connect the 1/4-inch tubing to the filter fitting and the 3/8-inch water supply tube to the quarter-turn shut-off valve. Insulate supply lines to reduce condensation.
  6. Drain Connection (Optional): If installing a drain, remove the drain basin, drill a hole, and connect the flexible drain hose to the house waste drain pipe. Reinstall the drain basin.
  7. Filtre kartuşunu takın: Write the installation date on the new filter. Insert the filter cartridge into the filter head and twist clockwise until seated.
  8. Su Teminini Etkinleştirin: Slowly open the water shut-off valve. Check for leaks.
  9. Güç Açık: Ensure the unit's power switch is off, then restore power at the circuit breaker. Turn the unit's power switch to the ON position.
  10. Sistemi Temizleyin: Dispense at least one gallon of water to bleed air and flush carbon particles from the filter.
  11. Son Montaj: Install the glass cover and filter box cover.

Video 1: How to Install an Elkay ezH2O Liv Built-in Filtered Water Dispenser. This video provides a detailed guide on the installation process, including plumbing and electrical connections.

Elkay Liv Recessed Bottle Filling Station installed in a home setting

Figure 2: Elkay Liv Recessed Bottle Filling Station in a home environment, showcasing entegre tasarımı.

The recessed design allows the unit to blend seamlessly into various home settings, providing convenient access to filtered water.

4. Kullanım Talimatları

The Elkay Liv Bottle Filling Station is designed for ease of use with hands-free operation.

4.1 Su Dağıtımı

4.2 Filter Status Lights

The unit features indicator lights to monitor filter life:

4.3 Plastic Bottles Saved Counter

The digital display tracks the number of 16.9 oz (500ml) plastic bottles saved by using the filtered water dispenser, promoting environmental awareness.

5. Bakım

Regular maintenance, particularly filter replacement, ensures the continued delivery of clean, fresh-tasting water.

5.1 Filtre Değişimi

It is recommended to replace the filter based on its capacity (750 gallons) or every 12 months, whichever comes first. The filter status lights will indicate when a replacement is due.

  1. Değişime Hazırlık: Shut off the water supply to the filter box using the shut-off valve. Place a bucket in the alcove to relieve pressure in the water line.
  2. Gücü Kesin: Shut off power to the unit at the circuit breaker.
  3. Erişim Filtresi: Remove the filter box cover by unscrewing the four screws.
  4. Eski Filtreyi Kaldır: Lift the water line. Place a towel in the cavity to absorb any water. Twist the old filter approximately a half turn counter-clockwise until it disengages. Remove the filter and drain it into the bucket.
  5. Yeni Filtre Yükle: Remove the protective cap from the new filter. Write the current date on the filter label. Insert the new filter cartridge into the filter head and twist clockwise until it is completely seated.
  6. Su ve Elektrik Bağlantılarını Yeniden Başlatın: Slowly open the water supply valve. Check for leaks. Restore power to the unit at the circuit breaker.
  7. Sifon Sistemi: Dispense at least one gallon of water to flush the new filter.
  8. Kapağı Yeniden Takın: Reinstall the filter box cover.

Video 2: How to Replace the Water Filter on an Elkay ezH2O Liv Built-in Filtered Water Dispenser. This video demonstrates the step-by-step process for replacing the water filter.

Elkay Liv Recessed Bottle Filling Station with filter compartment open

Figure 3: The filter compartment of the Elkay Liv Bottle Filling Station, showing easy access for filter replacement.

The lower panel of the unit provides convenient access to the water filter for routine maintenance.

6. Sorun Giderme

If you encounter issues with your Elkay Liv Bottle Filling Station, refer to the following common troubleshooting steps:

7. Özellikler

MarkaElkay
Model NumarasıLBWD00WHC
Ürün Boyutları18"D x 5.13"G x 28"Y
Ürün Ağırlığı25 pound
MalzemePaslanmaz çelik
Renkkavak beyazı
Kurulum TürüDahili
Güç KaynağıKablolu Elektrik
Cilttage115 Volt
Netage25 watt
Filtre Kapasitesi750 gallons (or 12 months)
Dimensions of Elkay Liv Recessed Bottle Filling Station

Şekil 4: Kurulum planlaması için ürün boyutları.

The unit measures 18 inches in width, 28 inches in height, and has a depth of 5.13 inches.

8. Garanti Bilgileri

For detailed warranty information regarding your Elkay Liv Recessed Bottle Filling Station, please refer to the warranty card included with your product packaging or visit the official Elkay webSite. Garanti şartları ve koşulları değişiklik gösterebilir.

9. Müşteri Desteği

If you require further assistance, have questions about your product, or need to order replacement parts, please contact Elkay customer support directly. Contact information can be found on the official Elkay websitenizde veya ürün dokümanlarınızda.

İlgili Belgeler - LBWD00WHC

Önview Elkay ezH2O® Dahili Filtreli, Vandalizme Karşı Dayanıklı Mekanik Şişe Dolum İstasyonu Kurulum ve Kullanım Kılavuzu
Elkay ezH2O® dahili filtreli, vandalizme karşı dayanıklı mekanik şişe doldurma istasyonunun kurulumu ve kullanımı için kapsamlı kılavuz. Filtre durumu izleme özelliğiyle birlikte güvenlik, hazırlık, kurulum, çalıştırma ve servis konularını kapsar.
Önview Elkay EZH2O Soğutmalı Yüzeye Monte Şişe Dolum İstasyonu Kullanım ve Bakım Kılavuzu
Bu kılavuz, Elkay EZH2O Soğutmalı Yüzeye Monte Şişe Dolum İstasyonları (EZ8WS ve LZ8WS serisi) için kapsamlı kullanım ve bakım talimatları sunmaktadır. Genel bilgiler, güvenlik önlemleri, gerekli araç ve gereçler, fabrika varsayılan ayarlarının değiştirilmesi, temizlik talimatları ve filtre kartuşu değişimi konularını kapsamaktadır.
Önview Elkay EZH2O Soğutmalı Yüzeye Monte Şişe Dolum İstasyonu Kullanım ve Bakım Kılavuzu
Elkay EZH2O Soğutmalı Yüzeye Monte Şişe Dolum İstasyonları (EZ8WS ve LZ8WS serisi) için kapsamlı kullanım ve bakım kılavuzu. Kurulum, temizlik, bakım ve sorun giderme bilgilerini içerir.
Önview Elkay Pro Filtrasyon Toplam PFAS + Kurşun Filtre Kullanım Kılavuzu ve Performans Veri Sayfası
Elkay Pro Filtrasyon sisteminin toplam PFAS ve Kurşun azaltımını, önerilen kullanım koşullarını, filtre değiştirme talimatlarını ve garanti bilgilerini kapsayan ayrıntılı performans veri sayfası ve kılavuzu.
Önview Elkay Enhanced LZ Series Bottle Filling Stations & Coolers Installation and Use Manual
Comprehensive installation and use manual for Elkay Enhanced LZ Series Bottle Filling Stations and Coolers, covering setup, operation, maintenance, and troubleshooting. Includes detailed diagrams, parts lists, and error code information.
Önview Elkay Enhanced LZ Series Bottle Filling Stations & Coolers Installation and Use Manual
This manual provides comprehensive installation, operation, and service instructions for the Elkay Enhanced LZ Series Bottle Filling Stations and Coolers. It covers setup procedures, component identification, programming, troubleshooting error codes, and parts lists for models featuring Connected Ready technology.