1. Giriş
This manual provides essential information for the safe and efficient operation of your Voltcraft VLP-2403 USB Adjustable Laboratory Power Supply. Please read this manual thoroughly before using the device and retain it for future reference.
The Voltcraft VLP-2403 is a high-precision laboratory power supply designed for various applications requiring stable and adjustable DC voltage and current. It features two independent outputs, USB connectivity, and overvoltage koruma.
2. Güvenlik Talimatları
Yaralanmayı veya cihaza zarar gelmesini önlemek için her zaman aşağıdaki güvenlik önlemlerine uyun:
- Güç kaynağının topraklı bir prize bağlı olduğundan emin olun.
- Cihazı ıslak veya nemli ortamlarda çalıştırmayın.amp koşullar.
- C'yi açmayınasing; Servis işlemlerini yetkili personele yaptırın.
- Çıkış terminallerinin kısa devre yapmasını önleyin.
- hacmi doğrulayıntage and current settings before connecting to a circuit.
- Aşırı ısınmayı önlemek için havalandırma açıklıklarını açık tutun.
3. Ürün Bittiview ve Bileşenler
Familiarize yourself with the main components of the Voltcraft VLP-2403 power supply.

Şekil 1: Ön Panel Üstüview
This image displays the front panel of the Voltcraft VLP-2403, showing the two main outputs (A and C) with their respective voltage and current displays, adjustment knobs, and output terminals. The central section features Output B-USB controls and USB ports. The power switch is located on the left.

Şekil 2: Arka Panel Üzeriview
This image shows the rear panel of the power supply, highlighting the cooling fins, product label, and the AC power input socket with its fuse holder. Proper ventilation is crucial for device operation.
Ön Panel Kontrolleri:
- Güç düğmesi: Üniteyi açar/kapatır.
- Output A/C Displays: Digital readouts for Voltage (V) and Current (A).
- Cilttage Adjustment Knobs: Fine and coarse adjustment for output voltage.
- Current Adjustment Knobs: Fine and coarse adjustment for output current limit.
- Çıkış Terminalleri: Red (+) and Black (-) terminals for connecting loads.
- Output B-USB Section: Controls and USB ports for dedicated USB power output.
- OVP (Aşırı hacimtage Protection) Adjustment: Sets the overvoltage koruma sınırı.
4. Kurulum
4.1 Paketin Açılması ve Muayene
- Güç kaynağını ambalajından dikkatlice çıkarın.
- Inspect the device for any signs of physical damage. If damage is found, do not operate the unit and contact your supplier.
- Ensure all accessories (e.g., power cord, test leads) are present.
4.2 Yerleştirme
- Place the power supply on a stable, level surface.
- Ensure adequate ventilation around the unit. Do not block the air vents on the sides and rear.
- Keep the device away from direct sunlight, heat sources, and excessive dust or moisture.
4.3 Güç Bağlantısı
- Ön paneldeki güç anahtarının "KAPALI" konumunda olduğundan emin olun.
- Connect the provided AC power cord to the power input socket on the rear panel.
- Plug the other end of the power cord into a suitable grounded AC power outlet (230V AC, 50Hz).
5. Kullanım Talimatları
5.1 Basic Operation (Output A and C)
- Güç Açık: Flip the power switch to the "ON" position. The displays will illuminate.
- Ön ayar Ses seviyesitage ve Akım:
- Before connecting your load, turn the voltage adjustment knobs (coarse and fine) to set the desired output voltage.
- Adjust the current adjustment knobs (coarse and fine) to set the maximum current limit. This acts as a protection mechanism for your circuit.
- Yükün Bağlanması: Connect the positive (+) terminal of your load to the red output terminal and the negative (-) terminal of your load to the black output terminal.
- İzleme: The displays will show the actual output voltage and current being supplied to your load.
- aşırı sestage Koruma (OVP): The OVP function protects the connected load from excessive voltage. Adjust the OVP knob to set the maximum permissible voltage. çıkış hacmi isetage exceeds this limit, the power supply will shut down the output.

Figure 3: Connecting Test Leads
This image demonstrates how to connect test leads to the output terminals of the power supply. Red leads connect to positive terminals, and blue/black leads connect to negative terminals.
5.2 USB Output Operation (Output B-USB)
The central Output B-USB section provides dedicated USB power outputs.
- Connect your USB device to one of the USB ports (USB-B1 or USB-B2).
- Use the "MODE" and "SHOW VALUE" controls to select the desired USB output voltage (e.g., 5V, 9V, 12V) and monitor its status.

Şekil 4: Kontrollerin Ayarlanması
A hand is shown adjusting one of the control knobs on the front panel, illustrating the user interaction with the device's settings.
5.3 Output Modes (Parallel, Series, Independent)
The VLP-2403 offers flexible output configurations for Outputs A and C:
- Independent Mode (IND): Outputs A and C operate as two separate, isolated power supplies.
- Series Mode (SER): Outputs A and C are connected in series to provide a higher voltage (up to 80V). Ensure proper wiring and voltage ayarları.
- Parallel Mode (PAR): Outputs A and C are connected in parallel to provide a higher current (up to 6A). Ensure proper wiring and current settings.
Refer to the front panel "MODE" switch in the Output B-USB section to select the desired configuration for Outputs A and C.
6. Bakım
6.1 Temizlik
- Disconnect the power supply from the mains before cleaning.
- Dış yüzeyini yumuşak bir bezle silin.amp bezle silin. Aşındırıcı temizleyiciler veya çözücüler kullanmayın.
- Cihazın içine sıvı girmemesine dikkat edin.
6.2 Havalandırma
- Regularly check that the ventilation openings on the sides and rear are free from dust and obstructions.
- Blocked vents can lead to overheating and damage.
6.3 Sigorta Değişimi
If the power supply does not turn on, check the fuse located in the AC input socket on the rear panel. Replace it only with a fuse of the same type and rating (e.g., T 3.15A / 250V).
7. Sorun Giderme
| Sorun | Olası Neden | Çözüm |
|---|---|---|
| No power, displays off. | Power cord disconnected, power outlet faulty, fuse blown. | Check power cord connection. Test outlet with another device. Replace fuse if blown (refer to 6.3). |
| çıkış hacmi yoktage/akım. | Output disabled, OVP triggered, current limit set too low, load disconnected. | Ensure output is enabled. Check OVP setting. Increase current limit. Verify load connection. |
| Çıkış hacmitage dalgalanır. | Unstable input power, faulty connection, internal issue. | Check mains power stability. Secure all connections. If problem persists, contact support. |
| Ünite aşırı ısınıyor. | Blocked ventilation, excessive load. | Clear ventilation openings. Reduce load or operating time. |
8. Özellikler
| Özellik | Detay |
|---|---|
| Marka | VOLTCRAFT |
| Model Numarası | VC-8146860 (VLP-2403) |
| Çıkış Kanalları | 4 (2 independent 0-40V/0.01-3A, 2 USB) |
| Çıkış Hacmitage (A/C) | 0 - 40 V DC (Adjustable) |
| Output Current (A/C) | 0.01 - 3 A (Ayarlanabilir) |
| Maksimum Güç | 273 B |
| Düzenleme Türü | Electronic linear regulation (low ripple) |
| Koruma | aşırı sestage Koruma (OVP) |
| Bağlayıcı Türü | USB (for Output B) |
| Soğutma Yöntemi | Hava |
| Boyutlar (U x G x Y) | 27x44x12.5 cm |
| Ağırlık | 11 kilo |
| Özel Özellikler | High-precision multi-turn potentiometer, USB developments |
9. Garanti ve Destek
Information regarding warranty terms and conditions is typically provided with the product packaging or on the manufacturer's official webLütfen siteyi ziyaret edin. Ayrıntılı garanti kapsamı için bu kaynaklara bakın.
For technical support, service, or inquiries, please contact VOLTCRAFT customer service. Contact details can usually be found on the product packaging, the VOLTCRAFT websitenizden veya satın alma noktanızdan.
Üretici: VOLTCRAFT