giriiş
The VOTRONIC VCC 1212-90 is a high-performance B2B (Battery-to-Battery) charge converter designed for universal use with various battery technologies, including conventional lead-acid, lead-gel, lead-AGM, and modern Lithium-LiFePO4 batteries. This device ensures optimal, fast, and gentle charging of your auxiliary battery from the alternator while driving, maintaining battery health and extending its lifespan.
Unlike simple cut-off relays, the VCC 1212-90 intelligently adjusts the charging voltage to the specific requirements of each battery type, ensuring a full charge. It effectively compensates for line losses and voltage fluctuations from the alternator, common in modern vehicles (e.g., Euro 6 with intelligent alternators). The compact and lightweight design, utilizing high-frequency switch-mode technology, ensures reliable operation and an improved energy balance for your onboard battery system.
The unit operates fully automatically, activating with the vehicle's alternator and preventing battery discharge when the engine is off. It also protects connected 12V consumers from overvoltage ve cilttage fluctuations. A battery temperature sensor is included for enhanced charging precision, especially for lead-acid batteries.
Kurulum ve Yükleme
Proper installation is crucial for the safe and efficient operation of your VOTRONIC VCC 1212-90 charge converter. It is recommended that installation be performed by a qualified technician.
- Montaj Yeri: Choose a dry, well-ventilated location for mounting the unit. Ensure it is protected from direct moisture and excessive heat. The compact dimensions (160 x 235 x 71 mm) allow for flexible placement.
- Kablo Bağlantıları:
- Connect the input terminals of the VCC 1212-90 to the 12V starter battery/alternator circuit.
- Connect the output terminals to the 12V auxiliary (onboard) battery.
- Ensure all wiring connections are secure and use appropriate cable diameters (e.g., 50mm² for high current applications) to minimize voltage drop and ensure full current flow.
- Connect the included battery temperature sensor to the designated port on the VCC 1212-90 and attach the sensor to the auxiliary battery for accurate temperature compensation during charging.
- Pil Tipi Seçimi: The VCC 1212-90 features selectable charging programs for different battery types (lead-acid, lead-gel, lead-AGM, LiFePO4). Refer to the detailed instructions provided with the product for selecting the correct charging program for your auxiliary battery.
- İlk Kontrol: After installation, verify all connections are correct and secure before powering on the system.

Image: The VOTRONIC VCC 1212-90 90A Charge Converter. This image shows the compact design of the unit, highlighting its various connection points for input, output, and the temperature sensor.
Kullanım Talimatları
The VOTRONIC VCC 1212-90 operates largely automatically once correctly installed and configured.
- Otomatik Aktivasyon: The device automatically activates when the vehicle's alternator is running and provides sufficient voltage. It will begin charging the auxiliary battery.
- Akıllı Şarj: The integrated microprocessor control with "IU1oU2oU3" charging lines and dynamic charge time calculation ensures a fast, gentle, and complete charge for the connected batteries from any state of charge.
- Simultaneous Power Supply: Even when 12V consumers are connected and drawing power, the VCC 1212-90 continues to charge or maintain the auxiliary battery's charge.
- Sıcaklık Telafisi: For lead-acid batteries, the charging voltage automatically adjusts to the battery temperature (via the connected sensor). This optimizes charging in cold conditions and prevents unnecessary gassing. For LiFePO4 batteries, it provides high-load battery protection and is adapted for low temperatures below 0°C.
- Motor Kapalı: When the engine is off, the VCC 1212-90 automatically disconnects, preventing discharge of the starter battery by the auxiliary battery or connected consumers.
- Paralel Çalışma: The unit can operate in parallel with other charging sources connected to the same auxiliary battery without issues.
Bakım
The VOTRONIC VCC 1212-90 is designed for maintenance-free operation. However, periodic checks can help ensure its longevity and optimal performance:
- Görsel Muayene: Cihazı ve bağlantılarını periyodik olarak hasar, korozyon veya gevşek kablolama belirtileri açısından kontrol edin.
- Temizlik: Keep the unit free from dust and debris to ensure proper heat dissipation. Use a dry, soft cloth for cleaning. Do not use liquid cleaners.
- Havalandırma: Ensure that the mounting location remains well-ventilated and that the cooling fins (if present) are not obstructed.
Sorun giderme
The VCC 1212-90 incorporates multiple protection mechanisms to ensure safe operation. If you encounter issues, consider the following:
- Şarj Çıkışı Yok:
- Ensure the vehicle engine is running and the alternator is producing sufficient voltage. The unit activates automatically with the alternator.
- Check all input and output cable connections for tightness and proper contact.
- Verify that the selected battery type setting is correct for your auxiliary battery.
- Lower Than Expected Charging Current:
- Confirm that the cable diameters used for both input and output are adequate for the 90A current rating. Undersized cables can lead to significant voltage drops and reduced charging current.
- Ensure the alternator itself is capable of delivering the required current. While the VCC 1212-90 compensates for voltage fluctuations, a weak alternator will limit overall performance.
- The device dynamically calculates charge time and current based on battery state and temperature. A battery that is already partially charged or at a higher temperature might draw less current.
- Aşırı Isınma:
- The unit has protection against overheating. If it shuts down due to high temperature, check for adequate ventilation around the device. Ensure no objects are blocking airflow to the cooling fins.
- Çalışmaya devam etmeden önce ünitenin soğumasını bekleyin.
- Hata Göstergeleri: The device features electronic regulation for protection against overcharge, overvoltage, short circuits, and reverse discharge. Consult the full product manual for specific error codes or indicator light patterns, if applicable.
If problems persist after performing these checks, please contact VOTRONIC customer support or a qualified service technician.
Teknik Özellikler
| Marka | VOTRONİK |
| Model Numarası | VCC 1212-90 (Sunroad Equipment) |
| Giriş Voltage | 12 Volt Doğru Akım |
| Çıkış Hacmitage | 12 Volt Doğru Akım |
| Güncel Derecelendirme | 90 Amporada |
| Önerilen Pil Kapasitesi | 150 - 600 Ah |
| Ürün Boyutları (D x G x Y) | 7.1x16x23.5 cm |
| Ürün Ağırlığı | 1.48 Kilogram |
| Renk | Gümüş |
| Bağlayıcı Türü | Cigarette Lighter Socket (12 V DC) - Note: This might refer to the input source type, not the physical connector on the unit itself for high current. Refer to installation guide for actual terminal types. |
| Uyumluluk | CE |
Garanti Bilgileri
Specific warranty details for the VOTRONIC VCC 1212-90 90A Charge Converter are not provided in this document. Please refer to the warranty card included with your product or visit the official VOTRONIC webKapsamlı garanti şartları ve koşulları için siteyi ziyaret edin.
Müşteri Desteği
For technical assistance, installation queries, or further information regarding your VOTRONIC VCC 1212-90, please contact VOTRONIC customer support. Contact details can typically be found on the manufacturer's official webyerinde veya ambalaj malzemelerinde.