This manual provides essential information for the safe and efficient operation of your Nedis UPSD2000VBK Uninterruptible Power Supply. Please read these instructions carefully before installation and use, and retain them for future reference. This UPS is designed to provide backup power and protect your electronic devices from power outagAni yükselişler, dalgalanmalar ve iniş çıkışlar.
Güvenlik Talimatları
- Sadece İç Mekanda Kullanım: This UPS is designed for indoor use in a controlled environment. Do not expose it to rain, snow, or direct sunlight.
- Havalandırma: Ensure adequate ventilation around the UPS. Do not block ventilation openings. Maintain at least 20 cm of clearance from walls or other obstructions.
- Güç Kaynağı: Connect the UPS to a properly grounded AC power outlet. Do not remove the grounding prong.
- Aşırı yük: Do not overload the UPS. The total power consumption of connected equipment must not exceed the UPS's rated capacity (1200 W).
- Pil Güvenliği: The UPS contains internal batteries. Do not attempt to open the UPS casing or service the batteries yourself. Refer all servicing to qualified personnel.
- Sıvı Teması: Avoid placing liquids on or near the UPS. In case of accidental spillage, immediately disconnect the UPS from the power source and contact support.
- Acil Durum Bağlantısının Kesilmesi: Ensure the AC power outlet for the UPS is easily accessible for quick disconnection in an emergency.
Ürün Bittiview
The Nedis UPSD2000VBK is a compact and efficient uninterruptible power supply. Familiarize yourself with its components before proceeding with installation.

Şekil 1: Ön ve yan view of the Nedis UPSD2000VBK. This image displays the main power button and the vertical strip of LED indicators on the front panel, along with ventilation grilles on the side.

Şekil 2: Arka view of the Nedis UPSD2000VBK. This image highlights the four power outlets, the USB communication port, and the RJ45 network protection ports (IN/OUT), along with the main power input and cooling fan.
Temel Bileşenler:
- Ön Panel: Power button, LED status indicators (AC mode, battery mode, fault, battery level).
- Arka panel: AC input, 4 x Schuko output sockets, USB communication port, RJ45 network protection ports (IN/OUT).
- Dahili: Sealed lead-acid batteries, inverter, charger, control circuitry.
Kurmak
1. Paketten çıkarma
- UPS paketini dikkatlice ambalajından çıkarın.
- Inspect the unit for any shipping damage. If damage is found, do not operate the unit and contact your dealer.
2. Yerleşim
- Place the UPS on a flat, stable surface in a well-ventilated area.
- Avoid locations with excessive dust, humidity, or extreme temperatures.
- Ensure the ambient temperature is between 0°C and 40°C (32°F and 104°F).
3. Cihazları Bağlama
- UPS güç kablosunu topraklı bir duvar prizine bağlayın.
- Plug your computer, monitor, and other critical devices into the output sockets on the rear of the UPS. Ensure the total load does not exceed 1200 W.
- İsteğe bağlı: Connect a USB cable from the UPS to your computer for monitoring software functionality (software not included, typically available from manufacturer's webalan).
- İsteğe bağlı: Connect network cables through the RJ45 IN/OUT ports to protect your network devices from surges.
4. İlk Şarj
For optimal performance, charge the UPS for at least 8 hours before initial use. Leave the UPS connected to the AC power outlet with no load connected during this period.
İşletim
1. Açma/Kapatma
- Açmak için: Ön paneldeki güç düğmesine yaklaşık 3 saniye basılı tutun; bir bip sesi duyana ve gösterge ışıkları yanana kadar bekleyin.
- Kapatmak: Press and hold the power button for approximately 3 seconds until you hear a beep and the indicators turn off.
2. Understanding Indicators and Alarms
The front panel features LED indicators and an audible alarm to communicate the UPS status:
- AC Mode (Green LED): Solid green indicates the UPS is operating on utility power and charging the battery.
- Battery Mode (Yellow LED): Flashing yellow indicates the UPS is operating on battery power. An audible alarm will sound periodically.
- Arıza (Kırmızı LED): Solid red indicates a fault condition. Refer to the troubleshooting section. An audible alarm may sound continuously.
- Pil Seviyesi Göstergeleri: A series of LEDs typically indicates the remaining battery capacity.
3. Pil Modunda Çalışma
When utility power fails, the UPS automatically switches to battery mode, providing power to connected devices. The duration of battery backup depends on the load connected. During battery mode, save your work and shut down your equipment properly to prevent data loss.
Bakım
1. Pil Bakımı
- To maximize battery life, keep the UPS connected to an AC outlet at all times.
- Perform a full discharge/recharge cycle every 3-6 months if the UPS is rarely used on battery power.
- Batteries are consumable items and will eventually require replacement. Contact qualified service personnel for battery replacement.
2. Temizlik
- Disconnect the UPS from the AC power outlet and all connected devices before cleaning.
- Use a soft, dry cloth to wipe the exterior surfaces. Do not use liquid or aerosol cleaners.
- Havalandırma açıklıklarının toz ve kirden arındırılmış olduğundan emin olun.
3. Depolama
- If storing the UPS for an extended period, turn it off and disconnect it from all power sources.
- Serin ve kuru yerde saklayınız.
- Recharge the UPS battery every 3 months to prevent battery degradation.
Sorun giderme
Review the following common issues and solutions before contacting technical support.
| Sorun | Olası Neden | Çözüm |
|---|---|---|
| UPS açılmıyor. | AC güç girişi yok. Pil tamamen boşalmış. | Check AC power cord connection. Ensure wall outlet has power. Allow UPS to charge for 8 hours. |
| UPS, AC modunda sürekli bip sesi çıkarıyor. | Overload condition. Internal fault. | Reduce connected load. Disconnect non-essential devices. If problem persists, contact support. |
| UPS sık sık akü moduna geçiyor. | Unstable utility power. Low battery capacity. | Check utility power quality. Allow battery to fully charge. Consider battery replacement if old. |
| Connected devices lose power during outage. | UPS overloaded. Battery depleted. | Ensure total load is within capacity. Allow UPS to recharge. |
Özellikler
| Özellik | Şartname |
|---|---|
| Örnek | UPSD2000VBK |
| Marka | Nedis |
| Kapasite | 2000VA / 1200W |
| Giriş Voltage | 120 Volt (AC) |
| Çıkış Soketleri | 4 (Schuko type) |
| Boyutlar (U x G x Y) | 14.5x40x20.5 cm |
| Ağırlık | 30 kilo |
| Pil Türü | Sealed Lead-Acid (internal, non-user replaceable) |
| Şarj Süresi | %90 kapasiteye ulaşma süresi 8 saat (tipik) |
| Çalışma Sıcaklığı | 0°C ila 40°C |
| Nem | %0-90 RH (yoğuşmasız) |
| İletişim Portu | USB |
| Ağ Koruması | RJ45 (IN/OUT) |
Garanti ve Destek
For warranty information, technical support, or service inquiries, please refer to the warranty card included with your product or visit the official Nedis website. Do not attempt to repair the unit yourself, as this may void your warranty and pose safety risks. Always contact qualified service personnel for assistance.