ADC Prosphyg 760

ADC Prosphyg 760 Cep Aneroid Sfigmomanometre Kullanım Kılavuzu

Model: Prosphyg 760

Marka: ADC

giriiş

This manual provides comprehensive instructions for the proper use, care, and maintenance of your ADC Prosphyg 760 Pocket Aneroid Sphygmomanometer. Please read this manual thoroughly before using the device to ensure accurate readings and safe operation. This device is designed for professional and personal use in measuring blood pressure.

Güvenlik Bilgileri

Always follow basic safety precautions when using medical devices. Failure to do so may result in inaccurate readings or injury.

Bileşenler

Your ADC Prosphyg 760 Sphygmomanometer typically includes the following components:

Placeholder image for ADC Prosphyg 760 Sphygmomanometer components

Image showing the typical components of an aneroid sphygmomanometer, including the gauge, cuff, and inflation bulb. Please note: The provided image is a placeholder and does not depict the actual product.

Kurmak

Before taking a measurement, ensure the device is properly assembled and the patient is prepared.

  1. Cuff Selection: Choose the appropriate cuff size for the patient's arm circumference. The cuff should fit snugly but not too tightly.
  2. Hasta Pozisyonlandırması: Have the patient sit comfortably with their back supported and feet flat on the floor. The arm chosen for measurement should be supported at heart level.
  3. Manşetin Yerleştirilmesi: Wrap the cuff around the bare upper arm, approximately 1 inch (2-3 cm) above the elbow crease. Ensure the artery marker on the cuff aligns with the brachial artery.
  4. Bileşenleri Bağlayın: Ensure the tubing securely connects the cuff to the aneroid gauge and inflation bulb.

Kullanım Talimatları

Follow these steps to accurately measure blood pressure using your ADC Prosphyg 760.

  1. Close Air Release Valve: Turn the air release valve (usually a screw valve on the inflation bulb) clockwise until it is fully closed. Do not overtighten.
  2. Inflate Cuff: Rapidly inflate the cuff by squeezing the inflation bulb until the gauge reads approximately 20-30 mmHg above the patient's usual systolic pressure, or until the radial pulse is no longer palpable.
  3. Deflate Cuff Slowly: Slowly open the air release valve by turning it counter-clockwise. The needle on the gauge should drop at a rate of 2-3 mmHg per second.
  4. Listen for Korotkoff Sounds (if using stethoscope):
    • Sistolik Basınç: Note the reading on the gauge when you hear the first clear, tapping sound (Korotkoff Phase I).
    • Diyastolik Basınç: Note the reading on the gauge when the sounds disappear completely (Korotkoff Phase V).
  5. Record Readings: Record both systolic and diastolic pressures.
  6. Tamamen söndürün: Once readings are taken, fully open the air release valve to deflate the cuff completely.
  7. Wait Between Readings: If taking multiple readings, wait at least 1-2 minutes between measurements.

Not: For accurate blood pressure measurement, it is recommended to use this device in conjunction with a stethoscope to auscultate Korotkoff sounds.

Bakım ve Özen

Proper care will extend the life and accuracy of your sphygmomanometer.

Sorun giderme

SorunOlası NedenÇözüm
Cuff does not inflate or inflates slowly.Air leak in cuff, tubing, or bulb; valve not closed.Check all connections for tightness. Ensure air release valve is fully closed. Inspect cuff and tubing for cracks or holes.
Gösterge ibresi sıfıra geri dönmüyor.Ölçüm cihazı kalibrasyon dışı veya hasarlı.Do not use. Contact ADC for calibration or repair.
Tutarsız veya hatalı okumalar.Improper cuff size or placement; patient movement; rapid deflation; gauge out of calibration.Ensure correct cuff size and proper placement. Instruct patient to remain still. Deflate cuff at 2-3 mmHg/sec. Check calibration.

Özellikler

Garanti ve Destek

ADC products are manufactured to high standards and are backed by a limited warranty. For specific warranty details, please refer to the warranty card included with your product or visit the official ADC webalan.

For technical support, calibration services, or replacement parts, please contact ADC customer service:

When contacting support, please have your model number (Prosphyg 760) and purchase date available.