ROGER TECHNOLOGY R30-1204

ROGER TECHNOLOGY R30/1204 Otomatik Sürgülü Kapı Motoru Kullanım Kılavuzu

Modeli: R30-1204

1. Giriş

This manual provides essential instructions for the installation, operation, and maintenance of the ROGER TECHNOLOGY R30/1204 Automatic Sliding Gate Motor. This electromechanical gear motor is designed for sliding gates weighing up to 1200 kg. It features an integrated H70 series control unit, an optical encoder, and a magnetic limit switch for precise and reliable operation. Please read this manual thoroughly before installation and use to ensure safe and correct operation.

2. Güvenlik Talimatları

Önemli: Failure to follow these safety instructions may result in serious injury or damage to property.

3. Ürün Bittiview

The ROGER TECHNOLOGY R30/1204 is a robust motor designed for automating sliding gates. Its compact design houses a powerful 230V AC motor, an integrated control unit, and advanced safety features.

ROGER TECHNOLOGY R30/1204 Automatic Sliding Gate Motor exterior view

Şekil 3.1: Dış view of the R30/1204 motor unit.

Internal components of ROGER TECHNOLOGY R30/1204 motor showing gears and motor

Figure 3.2: Internal components, highlighting the motor and gear mechanism.

Temel Özellikler:

4. Özellikler

ParametreDeğer
Model NumarasıR30-1204
MarkaROGER TEKNOLOJİSİ
Maksimum Kapı Ağırlığı1200 kilo
Hat Güç Kaynağı230 V AC - 50 Hz
Motor Güç Kaynağı230 V AC
Anma Gücü420 B
Görev Döngüsü%50
İtme800 Gün
Çalışma Sıcaklığı-20 ila +55 °C
Motor Protection Temperature150 °C
Kapı Hızı9.5 m/min (0.16 m/s)
Gearbox TypeGeri döndürülemez
Limit Anahtarı TipiManyetik
Kontrol ÜnitesiIntegrated H70/104AC
Kodlayıcı TipiOptik
Max Product Dimensions (L x W x H)325x162x295 mm
MalzemeMetal

5. Kurulum ve Kurulum

Installation of the R30/1204 motor requires technical expertise and should only be performed by qualified professionals. This section provides a general overview; refer to the detailed installation manual provided with the product for specific wiring diagrams and mounting instructions.

  1. Saha Hazırlığı: Ensure the gate track is clean, level, and free of obstructions. Prepare a stable concrete base for the motor unit.
  2. Motorun Montajı: Securely fasten the motor unit to the prepared base using appropriate anchor bolts. Ensure correct alignment with the gate rack.
  3. Rafın Kurulumu: Attach the gate rack to the sliding gate, ensuring proper meshing with the motor's pinion gear. Maintain a small clearance between the rack and the pinion.
  4. Elektrik Bağlantıları: Connect the motor to the 230V AC power supply. Wire the control unit (H70 series) according to the provided diagrams, including connections for safety photocells, remote controls, and other accessories.
  5. Limit Anahtarı Ayarı: Install and adjust the magnetic limit switches at the desired open and closed positions of the gate. These switches signal the motor to stop.
  6. İlk Programlama: Power on the system and perform the initial programming steps for the control unit, which typically involves learning the gate's travel limits and setting operational parameters.
  7. Güvenlik Cihazı Testi: Thoroughly test all safety devices, such as photocells and emergency stop buttons, to ensure they function correctly.

6. Kullanım Talimatları

Once installed and programmed, the R30/1204 motor provides automated control of your sliding gate.

7. Bakım

Regular maintenance ensures the longevity and reliable operation of your gate motor.

8. Sorun Giderme

Bu bölüm, karşılaşabileceğiniz yaygın sorunları ele almaktadır. Daha karmaşık sorunlar için kalifiye bir teknisyene danışın.

SorunOlası NedenÇözüm
Motor uzaktan kumandaya yanıt vermiyor.No power; remote battery dead; remote not programmed; safety device triggered.Check power supply; replace remote battery; reprogram remote; check photocells for obstructions.
Kapı beklenmedik bir şekilde duruyor.Obstruction detected by photocells or encoder; limit switch faulty; motor overheating.Clear obstructions; check limit switch connections; allow motor to cool down.
Kapı kısmen açılıyor/kapanıyor.Limit switches incorrectly set or faulty; gate obstruction.Re-adjust limit switches; clear any physical obstructions.
Motor alışılmadık sesler çıkarıyor.Lack of lubrication; worn gears; foreign object in mechanism.Lubricate moving parts; inspect gears for wear; remove any foreign objects. If noise persists, contact support.

9. Garanti ve Destek

Information regarding the specific warranty period and terms for the ROGER TECHNOLOGY R30/1204 motor is typically provided with the product documentation at the time of purchase. Please refer to your purchase receipt or contact your dealer for warranty details.

For technical support, spare parts, or service, please contact your authorized ROGER TECHNOLOGY dealer or installer.

İlgili Belgeler - R30-1204

Önview Roger Technology Otomasyon Sistemleri Kataloğu: Kapı ve Kapı Çözümleri
Roger Technology'nin sürgülü kapılar, kanatlı kapılar, seksiyonel kapılar ve yukarı açılır kapılar dahil olmak üzere kapsamlı kapı ve kapı otomasyon sistemleri yelpazesini keşfedin. Ayrıntılı ürün özellikleri, teknik özellikleri ve elektronik bileşenleri inceleyin.
Önview Roger Technology H30 Serisi Sürgülü Kapı Otomasyonu - Kurulum ve Kullanım Kılavuzu
Roger Technology'nin sürgülü kapılar için H30 serisi otomasyon sistemlerine yönelik kapsamlı kılavuz. Ürün açıklamaları, teknik veriler, kurulum prosedürleri, elektrik bağlantıları ve manuel açma/kapama işlemlerini kapsar.
Önview Roger Technology H30 Serisi Sürgülü Kapı Otomasyonu Kurulum ve Kullanım Kılavuzu
Roger Technology H30 serisi sürgülü kapı otomasyon sistemi için kurulum, teknik özellikler ve çalıştırma konularını kapsayan kapsamlı kılavuz. H30/643 ve H30/644 modelleri hakkında detaylı bilgiler içerir.
Önview ROGER TECHNOLOGY H30 Serisi Sürgülü Kapı Otomasyonu - Kurulum Kılavuzu
Bu kılavuz, ROGER TECHNOLOGY Serie H30 sürgülü kapı otomasyon sistemleri için kapsamlı kurulum talimatları, güvenlik önlemleri, teknik veriler ve iletişim bilgilerini içermektedir.
Önview H70/104AC - H70/105AC: Centrale di Comando per 1 Motore 230 Vac
Manuale di installazione per le centrali di comando ROGER TECHNOLOGY H70/104AC e H70/105AC, progettate per automazioni di cancelli scorrevoli a motore asincrono monofase 230 Vac. Include istruzioni dettagliate, caratteristiche tecniche e schemi di collegamento.
Önview ROGER TECHNOLOGY B70/1DC Control Unit for Sliding Gates - User Manual
Comprehensive user manual for the ROGER TECHNOLOGY B70/1DC control unit, designed for automated sliding gates. This guide provides detailed installation, configuration, operation, and troubleshooting information for professional installers and technicians.