Notifier ISO-X

Notifier ISO-X Fault Isolator Module User Manual

Model: ISO-X

1. Giriş

The Notifier ISO-X Alarm Fault Isolator Module is designed to protect fire alarm system Signaling Line Circuits (SLC) from wire-to-wire short circuits. This module ensures that a short circuit on the SLC loop does not disable the entire loop, allowing other devices on the loop to continue functioning normally. It is an essential component for maintaining system integrity and reliability in fire detection and alarm systems.

The ISO-X module is compatible with various Notifier fire alarm control panels, including NFS-3030, AM2020, AFP1010, NFS-640, AFP-400, AFP-300, AFP-200, AFP-100, and System 5000.

2. Ürün Bittiview

Notifier ISO-X Fault Isolator Module in its packaging

Şekil 2.1: Ön view of the Notifier ISO-X Fault Isolator Module in its original packaging. The module is white with the Notifier by Honeywell logo prominently displayed. The packaging indicates "ISO-X" and "417480".

Arka view of Notifier ISO-X Fault Isolator Module with wiring terminals

Şekil 2.2: Arka view of the Notifier ISO-X Fault Isolator Module, showing the mounting bracket and wiring terminals. Labels for SLC1 and SLC2 connections are visible, along with model number, country of origin (Mexico), and UL/FM listings. Installation instructions are referenced.

3. Kurulum ve Kurulum

Installation of the ISO-X module should only be performed by qualified personnel in accordance with all local and national electrical codes, and the manufacturer's specific installation instructions (document 156-3624 referenced on the module itself).

  1. Güç Bağlantısının Kesilmesi: Ensure all power to the fire alarm control panel and associated circuits is disconnected before beginning installation.
  2. Montaj: Mount the ISO-X module in a suitable location, typically within an electrical enclosure or junction box, using the provided mounting holes. Ensure proper ventilation if required by local codes.
  3. Kablolama: Connect the Signaling Line Circuit (SLC) wires to the designated terminals on the module. The module supports two SLC loops (SLC1 and SLC2) with positive (+) and negative (-) terminals for each. Refer to the wiring diagram provided with the module and the fire alarm control panel for correct polarity and connection points. The module is designed for 4-wire applications.
  4. Doğrulama: After wiring, visually inspect all connections to ensure they are secure and correctly terminated.
  5. Güç Restorasyonu: Restore power to the fire alarm control panel and verify proper operation of the SLC loop and connected devices.

Note: The module is designed for indoor, dry applications only.

4. Operasyon

The Notifier ISO-X module operates passively within the SLC loop. In the event of a wire-to-wire short circuit on the SLC loop, the ISO-X module automatically isolates the affected segment of the loop. This isolation prevents the short circuit from disrupting communication with other devices on the healthy segments of the loop.

Once the short circuit condition is cleared, the ISO-X module automatically restores the isolated segment to normal operation, allowing full communication across the entire SLC loop without manual intervention.

5. Bakım

The Notifier ISO-X module requires minimal maintenance. Regular system inspections and testing, as mandated by local fire codes and standards (e.g., NFPA 72), will ensure the continued proper functioning of the module and the overall fire alarm system.

6. Sorun Giderme

If a fault is indicated on the SLC loop, and the ISO-X module is suspected:

7. Özellikler

BağlanmakDeğer
MarkaBildirici
Model NumarasıISO-X
Parça NumarasıISO-X
UPC636836973661
Güç KaynağıCorded Electric (SLC Loop)
RenkBeyaz
Ürün Ağırlığı5.6 ons
Ürün Boyutları6 x 6 x 2 inç
Öğe Sayısı1
BaşvuruIndoor, Dry Applications Only
UyumlulukNFS-3030, AM2020, AFP1010, NFS-640, AFP-400, AFP-300, AFP-200, AFP-100, System 5000

8. Garanti ve Destek

For specific warranty information regarding your Notifier ISO-X module, please refer to the documentation provided with your purchase or contact Notifier directly. Warranty terms typically cover defects in materials and workmanship under normal use.

For technical support, installation assistance, or to report issues, please contact Notifier customer service or your authorized Notifier distributor. When contacting support, please have your product model number (ISO-X) and any relevant system information ready.

İletişim Bilgileri:

İlgili Belgeler - ISO-X

Önview Notifier MMX-1(A), CMX-2(A), and ISO-X Fault Isolator Module Installation Instructions
Installation guide for Notifier MMX-1(A) Monitor Module, CMX-2(A) Control Module, and ISO-X Fault Isolator Module. Provides details on general description, compatibility, mounting, wiring, and testing procedures.
Önview Notifier XP10-M(A) Ten-Input Monitor Module Technical Specifications
Detailed technical specifications and features for the Notifier XP10-M(A) Ten-Input Monitor Module, an addressable device for intelligent alarm systems.
Önview Notifier FCM-1(A) and FRM-1(A) Series Control and Relay Modules Data Sheet
Technical data sheet for Notifier's FCM-1(A) Addressable Control Module and FRM-1(A) Addressable Relay Module, detailing features, applications, specifications, and agency approvals for fire alarm systems.
Önview Notifier FZM-1A Interface Module: Installation and Maintenance Instructions
Comprehensive guide for installing and maintaining the Notifier FZM-1A Interface Module. Includes detailed specifications, wiring diagrams for NFPA Class B and Class A configurations, mounting instructions, and general descriptions for fire alarm systems.
Önview Notifier NCM-1 Noise Control Module: Technical Specifications and Installation Guide
Detailed technical specifications, features, and installation guidelines for the Notifier NCM-1 Noise Control Module, designed to reduce common mode noise on Signaling Line Circuits. Includes wiring specifications for AIM-200, AM2020, and AFP1010 systems.
Önview Notifier NRX-M711 Radyo Sistemi Giriş/Çıkış Modülü Kurulum Talimatları
Yangın alarm sistemleri için Notifier NRX-M711 radyo giriş-çıkış modülünün teknik özelliklerini, parça listesini, kablolamasını, programlamasını ve devreye alınmasını ayrıntılarıyla anlatan kapsamlı kurulum kılavuzu.