BEST LEDR-1

BEST LEDR-1 LED Emergency Light User Manual

Model: LEDR-1

1. Giriş

This manual provides essential instructions for the safe installation, operation, and maintenance of your BEST LEDR-1 LED Emergency Light. Please read this manual thoroughly before installation and retain it for future reference. The LEDR-1 is designed to provide reliable emergency illumination during power outages, ensuring safety in commercial and residential environments.

2. Önemli Güvenlik Talimatları

UYARI: Elektrik çarpması riski. Kurulum veya bakım işlemlerinden önce gücü kesin.

3. Paket İçeriği

Paketi açtığınızda tüm bileşenlerin mevcut ve hasarsız olduğundan emin olun:

4. Ürün Bittiview

The BEST LEDR-1 is a compact and efficient LED emergency light designed for wall-mount applications. It features a durable white thermoplastic housing and two adjustable LED lamp heads, providing 98 lumens of bright, white light (5000 Kelvin) during emergency situations. The unit operates on 120 Volts AC and includes a rechargeable NiCAD battery for backup power.

BEST LEDR-1 Emergency Light, front view

Şekil 1: Ön view of the BEST LEDR-1 Emergency Light. This image shows the compact white thermoplastic housing with two adjustable LED lamp kafalar.

Temel Özellikler:

5. Kurulum

The LEDR-1 is designed for flush wall mounting. Follow these steps for proper installation:

  1. Güç Bağlantısının Kesilmesi: Before beginning any installation, ensure that the main power supply to the circuit where the emergency light will be installed is turned OFF at the circuit breaker or fuse box.
  2. Montaj Yeri: Select a suitable wall location for mounting. The unit should be mounted at a height and in a position that allows for optimal light distribution during an emergency. Ensure the mounting surface is solid and can support the fixture's weight.
  3. Montaj Yüzeyini Hazırlayın: Use the provided mounting hardware (screws and anchors) to secure the mounting plate or backplate of the emergency light to the wall. If the unit has a separate mounting plate, attach it first.
  4. Kablo Bağlantıları:
    • Bağlan Siyah tel from the emergency light to the hot (live) wire from the building's electrical supply.
    • Bağlan beyaz tel from the emergency light to the nötr tel from the building's electrical supply.
    • Bağlan yeşil tel from the emergency light to the topraklama teli from the building's electrical supply.
    • Use the provided wire nuts to secure all connections. Ensure all connections are tight and properly insulated.
  5. Pil Bağlantısı: If the battery is not pre-connected, connect the battery pack to the circuit board. Ensure correct polarity.
  6. Güvenli Fikstür: Carefully tuck all wires into the junction box or fixture housing. Secure the emergency light fixture to the mounting plate or wall according to the specific design of the unit.
  7. Gücü Geri Yükle: Once the installation is complete and all connections are secure, restore power to the circuit. The CHARGE INDICATOR light on the unit should illuminate, indicating that the battery is charging.
  8. Başlangıç ​​ücreti: Allow the battery to charge for a minimum of 24 hours before performing the first test.

6. Operasyon

The BEST LEDR-1 Emergency Light operates automatically:

7. Bakım

Regular maintenance ensures the longevity and reliability of your emergency light.

Pil Testi:

Perform the following tests according to local codes and regulations (typically monthly and annually):

Temizlik:

Clean the exterior of the unit and lamp heads periodically with a soft, damp bezle silin. Aşındırıcı temizleyiciler veya çözücüler kullanmayın.

Pil Değişimi:

The NiCAD battery has a limited lifespan. If the unit fails the annual 90-minute test, the battery likely needs replacement. Contact a qualified electrician or the manufacturer for battery replacement instructions and compatible battery types.

8. Sorun Giderme

SorunOlası NedenÇözüm
Emergency lights do not turn ON during power outage or when test button is pressed.
  • No AC power to the unit.
  • Battery not connected or faulty.
  • Pil tam şarjlı değil.
  • Arızalı LEDamp kafalar.
  • Devre kesiciyi ve kablo bağlantılarını kontrol edin.
  • Ensure battery is properly connected. Allow 24 hours for initial charge.
  • Perform a 90-minute discharge test after 24-hour charge. Replace battery if necessary.
  • Yetkili servis personeliyle iletişime geçin.
Charge indicator light is OFF when AC power is present.
  • No AC power to the unit.
  • Faulty charge indicator LED.
  • Dahili devre arızası.
  • Devre kesiciyi ve kablo bağlantılarını kontrol edin.
  • Yetkili servis personeliyle iletişime geçin.
Emergency lights do not stay ON for 90 minutes during annual test.
  • Pil kullanım ömrünü tamamlamıştır.
  • Pil tam şarjlı değil.
  • Pili değiştirin.
  • Ensure unit has been connected to AC power for at least 24 hours prior to test.

9. Özellikler

ÖzellikDetay
Model NumarasıLEDR-1
MarkaEN İYİ
Konut MalzemesiWhite Thermoplastic
Işık Kaynağı TürüLED (2 heads)
Cilttage120 Volt AC
Netage2 watt
Parlaklık98 Lümen
Yeterlik49 lümen/watt
Renk Sıcaklığı5000 Kelvin
Pil TürüNiCAD (1 AA battery required, included)
Average Battery Life (Emergency Mode)90 dakikadır.
Kurulum TürüGömme Duvar Montajı
İç/Dış Mekan KullanımıSadece iç mekan
Ürün Boyutları (U x G x Y)14.75" x 3.75" x 3.75"
Ürün Ağırlığı0.01 Ons
Kontrol YöntemiRemote (Test Button)

10. Garanti ve Destek

The BEST LEDR-1 LED Emergency Light comes with a full manufacturer warranty. For specific warranty details, claims, or technical support, please refer to the warranty card included with your product or contact Best Lighting Products directly. Keep your purchase receipt as proof of purchase.

For assistance, please contact Best Lighting Products customer service.

İlgili Belgeler - LEDR-1

Önview BEST FC300 High-Performance Frequency Inverter User Manual
This user manual provides comprehensive guidance for the BEST FC300 series high-performance frequency inverter. It details installation, wiring, operation, parameter configuration, safety precautions, and troubleshooting to ensure optimal performance and longevity.
Önview BEST Hinges & Door Accessories Price List PL77 | August 2025 | dormakaba
The official BEST Hinges & Door Accessories Price List PL77, effective August 2025, featuring a comprehensive catalog of hinges, door accessories, specifications, finishes, and terms of sale from BEST, a dormakaba Group company.
Önview BEST Exit Alarm Systems: ALK, ALW, WALW - Technical Specifications
Detailed specifications for BEST Exit Alarm systems (ALK, ALW, WALW) and kits, including features, wiring, weatherization, and ordering information for Precision Series devices.
Önview Kanada'da EN İYİ Menteşeler ve Kapı Aksesuarları Fiyat Listesi | Ağustos 2025
Kanada'daki BEST Menteşe ve Kapı Aksesuarları için kapsamlı fiyat listesi, çeşitli menteşe türleri için ayrıntılı ürün özellikleri, seçenekler, kaplamalar ve fiyatlandırmayı içerir. Ağustos 2025 tarihli PL77 katalog bilgilerini de içerir.
Önview BEST Precision Exit Devices & Trims Price List PL78 | dormakaba
Discover the comprehensive BEST Precision Exit Devices & Trims Price List (PL78, March 2026) from dormakaba Group. This catalog details a wide array of high-security exit devices, trims, and hardware components, including wide stile, narrow stile, and specialized series. Find product specifications, ordering information, and pricing for commercial and architectural applications.
Önview BEST Sliding & Folding Hardware Price List PL77 - August 2025
Official price list for BEST Sliding & Folding Hardware, featuring bi-fold and pocket door track and hardware from dormakaba Group. Includes product models, specifications, and pricing.