1. Giriş
This manual provides essential information for the safe and efficient installation, operation, and maintenance of your Pedrollo UPm2/4-GE Multi-Stage Submersible Electric Water Pump. Please read this manual thoroughly before installation and use, and retain it for future reference.
The Pedrollo UP series of multi-stage submersible pumps features an innovative design that prevents impellers from blocking, even after extended periods of inactivity. This design ensures high efficiency and reliability, making these pumps suitable for clean water applications in domestic, civil, and agricultural settings. Typical uses include water distribution with pressure sets, garden and allotment irrigation, and pressure boosting.
2. Güvenlik Bilgileri
Kişisel yaralanmaları ve pompaya zarar gelmesini önlemek için her zaman aşağıdaki güvenlik önlemlerine uyun:
- Güç kaynağının pompanın hacmine uygun olduğundan emin oluntage gereksinimleri (240V).
- Herhangi bir kurulum, bakım veya onarım çalışması yapmadan önce elektrik bağlantısını kesin.
- Do not operate the pump with damaged cables or if the pump itself is visibly damaged.
- The pump is designed for clean water only. Do not use it for flammable, corrosive, or abrasive liquids.
- Elektrik sisteminin doğru şekilde topraklanmasını sağlayın.
- Keep children and unauthorized personnel away from the pump's operating area.
- Do not lift the pump by its electrical cable. Use a rope or chain attached to the pump's lifting eye.
3. Kurulum ve Kurulum
Proper installation is crucial for the pump's performance and longevity. Refer to the diagram below for a typical installation setup.

Şekil 1: Typical installation diagram, performance curves, and dimensional data for Pedrollo UPm2/4-GE submersible pumps. This image illustrates how the pump should be submerged in a water source, connected to a discharge pipe, and includes technical specifications and performance characteristics.
- Suya Dalma: The pump must be fully submerged in clean water. Ensure the water level is always above the pump's intake.
- Montaj: Secure the pump using a suitable rope or chain attached to the designated lifting point. Do not let the pump rest directly on the bottom if it's muddy or sandy.
- Boşaltım borusu: Connect a discharge pipe of appropriate diameter to the pump's outlet. Ensure all connections are watertight.
- Elektrik Bağlantısı: Connect the pump to a 240V power supply with proper grounding and a residual current device (RCD) for safety. Consult a qualified electrician if unsure.
- Şamandıra Anahtarı: If equipped with a float switch (as shown in Figure 1), ensure it can move freely to control the pump's on/off cycles based on water level.
4. Kullanım Talimatları
Once installed correctly, operating the Pedrollo UPm2/4-GE pump is straightforward:
- Ilk başlangıç: Ensure the pump is fully submerged and all connections are secure. Turn on the power supply. The pump will start automatically if the float switch is in the 'on' position (water level high enough).
- Sürekli Çalışma: The pump is designed for continuous operation within its specified limits. Monitor the water level to prevent dry running, especially if not using a float switch.
- Kapat: To stop the pump, turn off the power supply. If using a float switch, the pump will stop automatically when the water level drops below the minimum operating level.
- Su Kalitesi: The pump is intended for clean water. Pumping water with excessive sediment or debris can damage the impellers and motor.
5. Bakım
Düzenli bakım, pompanın optimum performans göstermesini ve ömrünü uzatmasını sağlar. Bakım yapmadan önce daima elektriği kesin.
- Temizlik: Periodically inspect the pump's intake screen for blockages from debris. Clean as necessary.
- Pervane Muayenesi: While the pump's design resists blocking, occasional inspection of the impellers for wear or damage is recommended, especially if performance degrades. This typically requires professional service.
- Kablo Denetimi: Check the power cable for any signs of damage, cuts, or fraying. Replace immediately if damaged.
- Kışlama: In freezing climates, remove the pump from the water source and store it in a frost-free environment if it will not be used during winter. Drain all water from the pump and pipes.
6. Sorun Giderme
Pompanızla ilgili sorunlarla karşılaşırsanız, aşağıdaki yaygın sorunlara ve çözümlere bakın:
| Sorun | Olası Neden | Çözüm |
|---|---|---|
| Pompa çalışmıyor | No power; Float switch in 'off' position; Motor overload; Damaged cable. | Check power supply and circuit breaker; Ensure float switch is free and water level is sufficient; Reset thermal overload protector (if present); Inspect and replace cable if damaged. |
| Pompa çalışıyor ama su gelmiyor veya debi düşük. | Intake blocked; Air in system; Discharge pipe blocked or kinked; Low water level; Worn impellers. | Clean intake screen; Bleed air from the system; Check and clear discharge pipe; Ensure pump is fully submerged; Contact service for impeller inspection. |
| Pompa beklenmedik bir şekilde duruyor | Overheating; Low water level (float switch activated); Electrical fault. | Allow pump to cool; Check water level; Inspect electrical connections and power supply. |
If troubleshooting steps do not resolve the issue, contact a qualified technician or Pedrollo customer support.
7. Özellikler
The following table details the technical specifications for the Pedrollo UPm2/4-GE Multi-Stage Submersible Electric Water Pump:

Şekil 2: Ön view of the Pedrollo UPm2/4-GE Multi-Stage Submersible Electric Water Pump, showcasing its stainless steel body, blue power cable, and orange float switch.
| Şartname | Değer |
|---|---|
| Marka | Pedrollo |
| Model Numarası | UPm2/4 (48SP2120A1) |
| Güç | 1 beygir |
| Cilttage | 240 Volt |
| Malzeme | Paslanmaz çelik |
| Güç Kaynağı | Elektrik kablosu |
| Maksimum Akış Hızı | Dakikada 80 Litre |
| Maksimum Kaldırma Yüksekliği | 62 Metre |
| ASIN | B018W45YV0 |
8. Garanti ve Destek
Specific warranty details for the Pedrollo UPm2/4-GE pump are not provided in this manual. For warranty information, please refer to the documentation included with your purchase or contact the seller (cemstore) or Pedrollo directly. For technical support or service, please reach out to the authorized Pedrollo service center in your region.