Notifier FMM 1

NOTIFIER FMM-1 Monitör Modülü Kullanım Kılavuzu

Model: FMM 1

1. Giriş

This manual provides essential information for the proper installation, operation, and maintenance of the Notifier FMM-1 Monitor Module. The FMM-1 is designed to monitor a circuit of normally open contact devices in a fire alarm system. It is an integral component for ensuring the safety and reliability of your fire detection system.

2. Güvenlik Bilgileri

Always adhere to local codes, standards, and regulations when installing and maintaining fire alarm equipment. Installation and servicing should only be performed by qualified personnel. Disconnect all power before servicing. Failure to follow these instructions may result in property damage, serious injury, or death.

  • Kurulum veya bakım öncesinde elektrik bağlantısının kesildiğinden emin olun.
  • Follow all wiring diagrams and instructions provided by Notifier.
  • Do not operate the module outside its specified environmental limits.
  • Modülü temiz tutun ve toz ve kalıntılardan uzak tutun.

3. Ürün Açıklaması ve Özellikleri

The Notifier FMM-1 is a compact monitor module designed for use with Notifier intelligent fire alarm control panels. It provides a single initiating device circuit (IDC) for monitoring normally open contact devices such as manual pull stations, waterflow switches, or supervisory switches. The module communicates with the control panel using the FlashScan protocol, allowing for fast and reliable communication.

Notifier FMM-1 Monitor Module

Şekil 3.1: Ön view of the Notifier FMM-1 Monitor Module, showing its compact design and terminal connections.

Multiple Notifier FMM-1 Monitor Modules in original packaging

Figure 3.2: Multiple Notifier FMM-1 Monitor Modules packaged in a box, indicating new, original packaging.

4. Kurulum ve Kurulum

The FMM-1 module is typically installed in a standard 4-inch square electrical box. It is designed for surface or flush mounting. Refer to the specific wiring diagrams provided with your Notifier fire alarm control panel for detailed connection instructions.

4.1 Kablolama

Connect the module to the Signaling Line Circuit (SLC) of the fire alarm control panel and to the initiating device circuit (IDC) according to the system's design and Notifier's documentation. Ensure proper polarity and termination for all connections.

4.2 Adresleme

Each FMM-1 module must be assigned a unique address on the SLC loop using the rotary switches on the module. Consult your control panel's manual for valid address ranges and programming procedures.

Video 4.1: Bir overview of the Notifier FMM-1 Monitor Module, showcasing its physical appearance and key features. This video provides a visual guide to the module's design.

5. Kullanım Talimatları

Once properly installed and addressed, the FMM-1 module operates automatically as part of the fire alarm system. It continuously monitors the connected initiating device circuit for changes in state (e.g., a pull station being activated, a waterflow switch closing). Upon detecting an alarm or supervisory condition, the module transmits this information to the fire alarm control panel, which then initiates the appropriate system response.

6. Bakım

Regular maintenance is crucial for the reliable operation of the FMM-1 module and the overall fire alarm system. Refer to NFPA 72 (National Fire Alarm and Signaling Code) and local authority having jurisdiction (AHJ) requirements for specific testing and maintenance schedules.

  • Yıllık inceleme: Visually inspect the module and its connections for any signs of damage, corrosion, or loose wiring.
  • Fonksiyonel Test: Periodically test the initiating devices connected to the FMM-1 to ensure they properly trigger an alarm or supervisory signal at the control panel.
  • Temizlik: If necessary, gently clean the module's exterior with a soft, dry cloth. Do not use abrasive cleaners or solvents.

7. Sorun Giderme

If the FMM-1 module or its associated circuit is indicating a fault condition on the fire alarm control panel, consider the following:

SorunOlası NedenÇözüm
Module Fault/TroubleIncorrect wiring, short circuit, open circuit on IDC, incorrect addressing, module failure.Verify wiring connections and polarity. Check for shorts or opens on the IDC. Confirm correct address setting. If issues persist, replace the module.
No Response from DeviceDevice not properly connected, device failure, wiring issue on IDC.Check connections at the initiating device and the FMM-1. Test the initiating device independently. Inspect IDC wiring for breaks or damage.

For complex issues, contact a certified fire alarm technician or Notifier technical support.

8. Özellikler

  • Marka: Bildirici
  • Modeli: FMM 1
  • Parça Numarası: FMM-1
  • UPC: 643485653585
  • Üretici: BİLDİRİCİ
  • Ürün Ağırlığı: 5.6 ons
  • Paket Boyutları: 6.5 x 5.75 x 1.9 inç
  • Renk: Ivery
  • İlk Mevcut Tarih: 28 Ağustos 2015

9. Garanti ve Destek

For warranty information and technical support, please refer to the official Notifier website or contact your authorized Notifier distributor. Keep your purchase receipt for warranty claims.

Notifier Official Webalan: www.notifier.com

İlgili Belgeler - FMM 1

Önview NOTIFIER AFP-200 Analog Yangın Paneli - Teknik Özellikler ve Özellikler
ayrıntılıview NOTIFIER AFP-200 Analog Yangın Paneli'nin özelliklerini, sistem kapasitesini, teknik özelliklerini, uyumlu cihazlarını ve programlama yöntemlerini kapsayan bir kılavuz. Kurum listeleri ve ürün bilgileri de dahildir.
Önview Protectowire Lineer Isı Dedektörü EPR ve EPR-M Serisi: Teknik Özellikler ve Kurulum Kılavuzu
Notifier'ın Protectowire Lineer Isı Dedektörü EPR ve EPR-M Serisi için kapsamlı kılavuz. Ürün özellikleri, teknik özellikler, kimyasal direnç, kurulum gereksinimleri ve endüstriyel yangın algılama uygulamaları için mevcut aksesuarları kapsar.
Önview NOTIFIER AFC-600 FlashScan® özellikli Akıllı Adreslenebilir Yangın Paneli
NOTIFIER AFC-600 Akıllı Adreslenebilir Yangın Panelinin FlashScan® protokolü, AWACS™™ algılama teknolojisi, programlama seçenekleri, sistem modülleri ve çeşitli cihazlarla uyumluluğu dahil olmak üzere ayrıntılı teknik özellikleri ve özellikleri.
Önview Notifier SLC Wiring Manual: Intelligent Control Panel Installation Guide
Comprehensive wiring manual for Notifier Intelligent Control Panel SLC devices. Covers installation, wiring requirements, device specifications, and safety precautions for fire alarm systems, supporting various Notifier FACPs.
Önview NOTIFIER ESD Dijital Pazarlama Yardım Kılavuzu: INSPIRE, Kendi Kendine Test, CLSS
ESD ortaklarına yönelik, NOTIFIER'ın yeni INSPIRE yangın güvenliği sistemlerini, Kendi Kendini Test Eden dedektörlerini ve Bağlantılı Yaşam Güvenliği Hizmetlerini (CLSS) tanıtmak için dijital pazarlama stratejilerini, sosyal medyayı ve iş birliği reklamlarını kullanma konusunda kapsamlı bir rehber.
Önview NOTIFIER N16 Fire Alarm Control Panel - Scalable, Connected Life Safety System
Explore the NOTIFIER N16 Fire Alarm Control Panel (FACP) from Honeywell, featuring a 10" touchscreen, scalable capacity for intelligent addressable devices, and integration with Connected Life Safety Services (CLSS). Learn about its features, specifications, and compatible components for advanced fire detection and evacuation.