This instruction manual provides essential information for the safe and efficient installation, operation, and maintenance of the BFT P125020 BBT Battery Kit. This kit is designed to provide backup power to compatible BFT gate or door actuators, ensuring continued operation during power outages. Please read this manual thoroughly before proceeding with installation or use. Keep this manual for future reference.
2. Güvenlik Bilgileri
UYARI: Bu güvenlik talimatlarına uyulmaması elektrik çarpmasına, yangına, ciddi yaralanmaya veya ölüme yol açabilir.
- Kurulum, yerel elektrik yönetmeliklerine ve kurallarına uygun olarak, yetkili personel tarafından yapılmalıdır.
- Disconnect main power to the actuator before installing or servicing the battery kit.
- Do not expose the battery kit to moisture, rain, or extreme temperatures.
- Ensure proper ventilation around the battery kit.
- Akü terminallerini kısa devre yapmayın.
- Eski pilleri yerel çevre düzenlemelerine uygun şekilde atın.
- Use only genuine BFT replacement parts and accessories.
3. Paket İçeriği
Kuruluma başlamadan önce tüm bileşenlerin mevcut ve hasarsız olduğundan emin olun.
- BFT P125020 BBT Battery Kit (main unit)
- Connection cables (if applicable, check packaging)
- Montaj donanımı (varsa, ambalajı kontrol edin)
Note: Specific contents may vary slightly. Refer to your product packaging for an exact list.
4. Kurulum ve Kurulum
This section outlines the general steps for installing the BFT P125020 BBT Battery Kit. Always refer to the specific wiring diagrams provided with your BFT actuator control unit for precise connection details.
4.1 Gerekli Araçlar
- Tornavidalar (Phillips ve düz uçlu)
- Tel sıyırıcılar/kesiciler
- Multimetre (doğrulama için)
- Drill (if mounting)
4.2 Kurulum Adımları
- Güç Bağlantısının Kesilmesi: Ensure the main power supply to the BFT actuator control unit is completely disconnected and locked out. Verify with a multimeter.
- Montaj (Opsiyonel): If the battery kit requires mounting, select a suitable location near the actuator control unit, ensuring it is protected from weather and has adequate ventilation. Secure the kit using appropriate mounting hardware.
- Connect to Control Unit: Locate the dedicated battery connection terminals on your BFT actuator control unit. These are typically labeled for battery input.
- Kablo Bağlantıları: Connect the positive (+) terminal of the battery kit to the positive (+) battery input terminal on the control unit. Connect the negative (-) terminal of the battery kit to the negative (-) battery input terminal on the control unit. Ensure all connections are secure and correctly polarized.
- Güvenli Kablolama: Route and secure all wiring to prevent accidental disconnection or damage.
- Başlangıç ücreti: Once connected, restore main power to the actuator control unit. The battery kit will begin charging automatically. Allow sufficient time for the initial charge before relying on battery backup.

Şekil 1: BFT P125020 BBT Battery Kit. This image shows the compact design of the battery kit, which provides essential backup power for BFT gate and door actuators.
5. Kullanım Talimatları
The BFT P125020 BBT Battery Kit operates automatically once correctly installed and connected to a compatible BFT actuator control unit.
- Otomatik Şarj: When main power is supplied to the actuator control unit, the battery kit will automatically charge its internal batteries.
- Güç Yedekleme: In the event of a main power failure, the battery kit will seamlessly provide power to the actuator, allowing for continued operation for a limited number of cycles, depending on the battery charge level and actuator usage.
- Düşük Pil Göstergesi: Some BFT control units may provide an indication of low battery status. Refer to your actuator's control unit manual for specific details.
6. Bakım
Regular maintenance helps ensure the longevity and reliable operation of your BFT P125020 BBT Battery Kit.
- Görsel Muayene: Periodically inspect the battery kit and its connections for any signs of damage, corrosion, or loose wiring.
- Temizlik: Keep the battery kit clean and free from dust and debris. Use a dry, soft cloth for cleaning. Do not use abrasive cleaners or solvents.
- Pil Değişimi: Batteries have a limited lifespan. If the battery kit no longer provides adequate backup power, the internal batteries may need replacement. Contact BFT support or a qualified technician for battery replacement.
- Çevresel Koşullar: Ensure the battery kit remains within its specified operating temperature range and is protected from direct sunlight and moisture.
7. Sorun Giderme
If you experience issues with your BFT P125020 BBT Battery Kit, refer to the following common problems and solutions.
| Sorun | Olası Neden | Çözüm |
|---|---|---|
| Actuator does not operate during power outage. | Battery kit not charged; faulty connections; depleted batteries. |
|
| Battery kit not charging. | No main power to control unit; faulty connection to control unit; internal fault. |
|
| Reduced backup operation time. | Batteries are aging or not fully charged. |
|
For issues not covered here, or if troubleshooting steps do not resolve the problem, contact BFT technical support.
8. Özellikler
| Özellik | Detay |
|---|---|
| Model Numarası | P125020 |
| Üretici | BFT |
| Ürün Boyutları (U x G x Y) | 10x30x30 cm |
| Ağırlık | 100 Gram |
| Piller Dahil | No (Note: This refers to separate batteries, the kit itself contains internal batteries for backup.) |
| ASIN | B014V6TH0M |
Not: Özellikler önceden haber verilmeksizin değiştirilebilir.
9. Garanti Bilgileri
BFT products are covered by a manufacturer's warranty against defects in materials and workmanship. The duration and terms of the warranty may vary by region and product. Please retain your proof of purchase. For detailed warranty information, refer to the official BFT website or contact your local BFT distributor.
This warranty does not cover damage caused by improper installation, misuse, neglect, unauthorized repairs, or acts of nature.
10. Destek
For technical assistance, spare parts, or further information regarding the BFT P125020 BBT Battery Kit, please contact BFT customer support or your authorized BFT dealer.
- BFT Resmi Webalan: www.bft-otomasyon.com
- Yerel Distribütör: Refer to the BFT website for a list of authorized distributors in your area.
When contacting support, please have your product model number (P125020) and proof of purchase readily available.