giriiş
This manual provides essential information for the installation, operation, and maintenance of the Heatilator Old Style Propane (LP) Pilot Assembly, identified by part numbers 25732 and its current equivalent, 4021-729. This assembly is designed for specific Hearth & Home gas stoves and fireplaces that operate without a thermocouple. Please read all instructions carefully before proceeding with installation or service.
Güvenlik Bilgileri
UYARI: Yanlış kurulum, ayar, değişiklik, servis veya bakım yaralanmaya veya maddi hasara neden olabilir. Bu kılavuza bakın. Yardım veya ek bilgi için yetkili bir kurulumcuya, servis kuruluşuna veya gaz tedarikçisine danışın.
- Gaz Güvenliği: Always turn off the gas supply to the appliance before performing any service or maintenance.
- Elektriksel Güvenlik: Disconnect electrical power to the appliance before installation or service.
- Kalifiye Personel: Installation and service must be performed by a qualified service technician.
- Kaçak testi: After any gas connection is made, always test for gas leaks using a non-corrosive leak detection solution. Never use an open flame.
- Karbonmonoksit: Ensure proper ventilation and regularly check for carbon monoxide leaks. Carbon monoxide is an odorless, colorless gas that can cause serious injury or death.
- Orijinal Parçalar: Use only genuine replacement parts as specified by the manufacturer.
Paket İçeriği
Kuruluma başlamadan önce tüm bileşenlerin mevcut ve hasarsız olduğundan emin olun.
- 1 x Heatilator Old Style Propane Pilot Assembly (Part #25732 / #4021-729)

Figure 1: Complete Heatilator Old Style Propane Pilot Assembly, showing the pilot burner, igniter, gas line, and electrical connections.
Uyumluluk
This pilot assembly (HHT part #4021-729, replacing old part #25732) is a replacement propane (LP) pilot assembly for Hearth & Home gas stoves and fireplaces that do not utilize a thermocouple. It is compatible with the following HHT gas fireplace models. Always verify compatibility with your appliance's owner's manual.
Quadra-Fire Gas Stoves:
- DV400 & DV400L (Pre date code 12/96)
Heatilator Gas Fireplaces:
- EZ & EZL
- G112HA & G112HAL
- G360S & G360SL
- G520CL & G520CLL
- G520CR & G520CRL
- G760CH & G760CHL
- G920FL & G920FLL
- GC112 & GC112L
- GC300FL & GC300FLL (Pre date code 21/96)
- GC300ST & GC300STL (Pre date code 21/96)
- GC400SF & GC400SFL (Pre date code 21/96)
- GC500CL & GC500CLL (Pre date code 21/96)
- GC500CR & GC500CRL (Pre date code 21/96)
- GC720 & GC720L
- GC920 & GC920L
- CGC150 & CGC150L (Pre date code 39/95)
- CGC400 & CGC400L
- G136 & G136L
- G200 & G200L
- G340 & G340L
- G420 & G420L
- GC100A & GC100AL
- GC136 & GC136L
- GC150 & GC150L (Pre date code 39/95)
- GC200 & GC200L
- GC300 & GC300L
- GC340 & GC340L
- GC341 & GC341L
- GC341A & GC341AL
- GC361 & GC361L
- GC400 & GC400L
- GC420 & GC420L
- GC421 & GC421L
- GC1990 & GC1990L
- GC2000 & GC2000L
- GGBC36 & GGBC36L
- GGBC42 & GGBC42L
- GGBR36 & GGBR36L
- GGBR42 & GGBR42L
- DLS2 & DLS2L
- DLS18 & DLS18L
- DLS24 & DLS24L
- DLS30 & DLS30L
- FD36M & FD36ML
- FD42M & FD42ML
Kurulum Talimatları
This procedure should only be performed by a qualified service technician.
- Hazırlık:
- Turn off the gas supply to the appliance at the main shut-off valve.
- Cihazın elektrik bağlantısını kesin.
- Çalışıyorsa cihazın tamamen soğumasını bekleyin.
- Access the pilot assembly area within your fireplace or stove, typically by removing the log set, burner, or access panels.
- Removal of Old Pilot Assembly:
- Carefully disconnect the gas line from the old pilot assembly. Be prepared for a small amount of residual gas.
- Disconnect any electrical wires (e.g., igniter wire) from the old assembly. Note their connections for reinstallation.
- Unscrew or unclip the mounting bracket that secures the old pilot assembly to the burner or firebox.
- Remove the old pilot assembly from the appliance.

Şekil 2: Yakın çekim view of the pilot assembly, highlighting the pilot burner, igniter, and mounting bracket with screw holes.
- Installation of New Pilot Assembly:
- Position the new pilot assembly in the same location as the old one.
- Secure the pilot assembly using its mounting bracket and appropriate screws. Ensure it is firmly in place and correctly oriented.
- Connect the gas line to the new pilot assembly. Use a pipe thread sealant approved for gas connections. Tighten securely but do not overtighten.
- Connect the electrical wires (e.g., igniter wire) to the corresponding terminals on the new pilot assembly. Refer to your appliance's wiring diagram if unsure.

Şekil 3: Ayrıntılı view of the pilot assembly's igniter electrode and the gas inlet connection point.

Figure 4: Electrical spade connectors used for wiring the pilot assembly, ensuring a secure connection.
- Kaçak testi:
- Slowly turn on the main gas supply to the appliance.
- Apply a non-corrosive leak detection solution to all gas connections made during installation.
- Look for bubbles, which indicate a gas leak. If bubbles are present, turn off the gas supply immediately, tighten the connection, and retest. Repeat until no leaks are detected.
- Test İşlemi:
- Cihazın elektrik gücünü geri verin.
- Follow your appliance's specific instructions to light the pilot.
- Observe the pilot flame. It should be steady, blue, and impinge correctly on the main burner port to ensure proper ignition.
- If the pilot does not light or stay lit, refer to the Troubleshooting section.
Operasyon Bittiview
The pilot assembly serves as a continuous ignition source for your gas fireplace or stove. When the appliance is called to heat, the pilot flame ignites the main burner. This specific pilot assembly operates without a thermocouple, relying on other safety mechanisms within your appliance to monitor pilot flame presence.
Bakım
Regular inspection and cleaning can prolong the life and ensure the safe operation of your pilot assembly. Perform these checks annually or as recommended by your appliance's manufacturer.
- Görsel Muayene: Check the pilot flame for proper size and color (should be blue with a small yellow tip). Ensure it is directed correctly towards the main burner.
- Temizlik: Gently clean any dust, lint, or debris from the pilot burner and igniter electrode using a soft brush or compressed air. Ensure the pilot orifice is clear.
- Bağlantılar: Inspect all gas and electrical connections for tightness and signs of wear or corrosion.
Sorun giderme
If you experience issues with your pilot assembly, consult this section. For persistent problems, contact a qualified service technician.
| Sorun | Olası Neden | Çözüm |
|---|---|---|
| Pilot yanmayacak |
|
|
| Pilot lights but goes out |
|
|
| Weak or yellow pilot flame |
|
|
Özellikler
| Parça Numaraları | 25732 (Old Style), 4021-729 (Current) |
| Yakıt Türü | Propan (LP) |
| Termokupl | Not included / For units without a thermocouple |
| Üretici | HHT (Heat & Glo / Heatilator) |
| Ürün Ağırlığı | 4.9 ons |
| Paket Boyutları | 7.76 x 5.75 x 2.05 inç |
| ASIN | B00MPXSMT6 |
| Ürün Model Numarası (Dahili) | 8541800512 |
| Piller Gerekli | HAYIR |
Garanti ve Destek
For warranty information or technical support regarding your Heatilator Old Style Propane Pilot Assembly, please refer to the documentation provided with your specific Hearth & Home appliance or contact the manufacturer directly. Always ensure that any service or replacement is performed by a qualified professional.