Notifier FMM-1

Notifier FMM-1 Akıllı Adreslenebilir Monitör Modülü Kullanım Kılavuzu

Model: FMM-1

1. Giriş ve Üzeriview

The Notifier FMM-1 is an intelligent addressable monitor module designed for use with Notifier's ONYX series and other compatible fire alarm control panels. This module allows conventional alarm initiating devices, such as manual pull stations, normally open contact devices, or waterflow switches, to be connected to an intelligent fire alarm system. It monitors the status of these devices and reports their condition (normal, alarm, or trouble) back to the control panel.

The FMM-1 module is a crucial component for integrating existing conventional devices into modern addressable fire detection systems, providing precise location identification for alarms and troubles.

Ön view of the Notifier FMM-1 Intelligent Addressable Monitor Module, showing the Notifier by Honeywell logo and two small indicator lights.

Şekil 1: Ön view of the Notifier FMM-1 module. This image displays the module's front face, featuring the "Notifier by Honeywell" branding and two small circular indicators, likely for status or activity.

2. Kurulum ve Kurulum

Installation of the FMM-1 module should only be performed by qualified personnel in accordance with all local and national electrical codes, and the manufacturer's instructions. Ensure that all power to the fire alarm control panel and associated circuits is disconnected before beginning installation.

2.1 Montaj

The FMM-1 module is designed for mounting in a standard 4-inch square, 2-1/8 inch deep electrical box. It can also be mounted in a surface-mount box (SMB500) or a standard 1-gang box. The module includes mounting tabs for secure installation.

Ön ve arka view of the Notifier FMM-1 module, showing the white plastic cover and the grey metal base with wiring terminals.

Figure 2: Front and back components of the Notifier FMM-1 module. This image illustrates both the front cover and the rear mounting plate, which houses the terminal connections for wiring.

2.2 Kablolama

The FMM-1 module connects to the Signaling Line Circuit (SLC) of the fire alarm control panel and to the conventional initiating device circuit (IDC). Refer to the specific wiring diagrams provided with the module and the fire alarm control panel for correct connections. Ensure proper polarity for all connections.

Close-up of the back of the Notifier FMM-1 module, showing wiring terminals, model number, and regulatory markings like UL Listed and FM Approved.

Şekil 3: Arka view of the Notifier FMM-1 module with wiring details. This image provides a clear view of the terminal block for connecting to the fire alarm system's Signaling Line Circuit (SLC) and the initiating device circuit (IDC), along with product labels and certifications.

After wiring, verify all connections are secure and correct before applying power to the system.

3. Çalışma Prensipleri

Once properly installed and addressed, the FMM-1 module operates by continuously monitoring the connected conventional initiating device circuit. It communicates the status of this circuit to the intelligent fire alarm control panel via the SLC.

The module's LED indicators (if present) may provide local visual indication of its status, such as flashing during normal operation or solid during an alarm/trouble condition. Refer to the specific product documentation for LED behavior.

4. Bakım

The Notifier FMM-1 module is designed for reliable, long-term operation with minimal maintenance. However, regular system-wide inspections and testing are crucial for ensuring the continued proper functioning of the fire alarm system.

Any maintenance or repair work beyond simple visual inspection and cleaning should be performed by a certified fire alarm technician.

5. Sorun Giderme

If the FMM-1 module or its connected devices are not functioning as expected, consider the following troubleshooting steps. Always ensure power is disconnected before inspecting wiring.

BelirtiOlası NedenÇözüm
Module reports trouble condition.Open circuit, short circuit, or ground fault on IDC; incorrect EOLR; module addressing error.Verify IDC wiring for breaks or shorts. Check EOLR value and placement. Confirm module address is unique and correctly set.
Module not communicating with control panel.Incorrect SLC wiring; module address conflict; faulty module.Check SLC wiring for proper polarity and continuity. Ensure no duplicate addresses on the SLC. If issues persist, module may need replacement.
Connected device does not report alarm.Faulty initiating device; incorrect IDC wiring; module not configured correctly.Test the initiating device directly. Verify IDC wiring to the device. Confirm module programming in the control panel.

For complex issues or if troubleshooting steps do not resolve the problem, contact a certified fire alarm technician or Notifier technical support.

6. Özellikler

The following are key specifications for the Notifier FMM-1 Intelligent Addressable Monitor Module:

Notifier FMM-1 module in its original packaging, alongside a small instruction manual and a few small components.

Figure 4: Notifier FMM-1 module as packaged. This image shows the module, its clear plastic packaging, and the included installation and maintenance instructions, along with minor accessories.

7. Garanti ve Destek

For specific warranty information regarding the Notifier FMM-1 Intelligent Addressable Monitor Module, please refer to the warranty documentation provided with your purchase or contact your authorized Notifier distributor or reseller. Warranty terms typically cover defects in materials and workmanship for a specified period from the date of purchase.

For technical support, installation assistance, or service inquiries, please contact Notifier's official customer support channels or your certified fire alarm system installer. Always provide your product model number (FMM-1) and any relevant system details when seeking support.

Notifier Official Webalan: www.notifier.com

İlgili Belgeler - FMM-1

Önview NOTIFIER NFS-3030 Akıllı Adreslenebilir Yangın Alarm Sistemi | Teknik Veri Sayfası
ONYX Serisi'nden akıllı adreslenebilir yangın alarm kontrol paneli NOTIFIER NFS-3030'u keşfedin. Orta ve büyük ölçekli tesisler için tasarlanan bu panel, kritik yangın güvenliği uygulamaları için gelişmiş algılama, modülerlik ve kapsamlı cihaz desteği sunar.
Önview Notifier NFS-320 Akıllı Adreslenebilir Yangın Alarm Sistemi Veri Sayfası
Notifier NFS-320 Akıllı Adreslenebilir Yangın Alarm Sistemi'nin özelliklerini, akıllı algılama yeteneklerini, FlashScan protokolünü, sistem özelliklerini, uyumlu cihazları ve kurum onaylarını ayrıntılı olarak açıklayan kapsamlı veri sayfası.
Önview Notifier NFS-640 Akıllı Adreslenebilir Yangın Alarm Sistemi Veri Sayfası
ayrıntılıview of the Notifier NFS-640 Intelligent Addressable Fire Alarm Control Panel, covering its features, advanced FlashScan® protocol, intelligent sensing capabilities, programming options, system modules, and comprehensive technical specifications.
Önview Notifier AM-8000 Akıllı Adreslenebilir Yangın Algılama Kurulum Kılavuzu
Bu kurulum kılavuzu, Notifier AM-8000 Akıllı Adreslenebilir Yangın Algılama sistemi için kapsamlı bir kılavuz sunar.view, teknik özellikler, elektriksel özellikler, montaj prosedürleri, kablo şemaları, güç kaynağı hesaplamaları, test ve bakım.
Önview NOTIFIER AFP-200 Analog Yangın Paneli - Teknik Özellikler ve Özellikler
ayrıntılıview NOTIFIER AFP-200 Analog Yangın Paneli'nin özelliklerini, sistem kapasitesini, teknik özelliklerini, uyumlu cihazlarını ve programlama yöntemlerini kapsayan bir kılavuz. Kurum listeleri ve ürün bilgileri de dahildir.
Önview FlashScan® Özellikli Notifier AFC-600 Akıllı Adreslenebilir Yangın Alarm Kontrol Paneli Veri Sayfası
Notifier AFC-600 Akıllı Adreslenebilir Yangın Alarm Kontrol Paneli'nin özelliklerini, teknik özelliklerini, sistem kapasitesini, programlama seçeneklerini, uyumlu cihazlarını ve kurum onaylarını ayrıntılı olarak açıklayan kapsamlı veri sayfası. FlashScan® protokolü ve AWACS™™ algılama teknolojisi hakkında bilgiler içerir.