1. Giriş
This manual provides essential information for the safe and efficient installation, operation, and maintenance of your Steinbach 040955 CPS 40-2 Filtration Pump. Please read these instructions carefully before using the pump to ensure proper function and longevity of the product. This pump is designed for filtering pool water up to approximately 19,000 liters capacity and is compatible with Steinbach Classic 300, Classic 250, and ActiveBalls+ filtration systems.
2. Güvenlik Talimatları
Always observe the following safety precautions to prevent injury or damage to the pump.
- Elektriksel Güvenlik: Ensure the power supply matches the pump's specifications (240 Volts). Always disconnect the pump from the power supply before performing any maintenance or cleaning. Do not operate the pump with a damaged power cord or plug.
- Su güvenliği: Never operate the pump dry. Ensure the pump is fully primed with water before starting. Keep children and pets away from the pump during operation.
- Atama: Install the pump on a stable, level surface. Ensure adequate ventilation around the pump to prevent overheating.
- Sıcaklık: The pump is designed for water temperatures up to 35 degrees Celsius.
3. Ürün Bittiview
The Steinbach 040955 CPS 40-2 is a robust filtration pump designed for efficient pool water circulation. It features a durable plastic housing and an electric cable power source. The pump is compact and operates quietly.

Şekil 3.1: Ön view of the Steinbach 040955 CPS 40-2 Filtration Pump.

Şekil 3.2: Yan view of the pump, showing the inlet and outlet connections.

Figure 3.3: Visual representation of the pump's dimensions, approximately 20 cm (8.2 inches) in height.

Figure 3.4: Product packaging displaying key specifications such as 230V/200W power, 6.5m max head, and 6000 l/h flow rate.
4. Kurulum
Follow these steps for proper installation of your filtration pump:
- Paketin açılması: Tüm bileşenleri ambalajından dikkatlice çıkarın. Herhangi bir hasar olup olmadığını kontrol edin.
- Atama: Position the pump on a firm, level surface near your pool, ensuring it is protected from direct weather exposure and has adequate air circulation.
- Hortum Bağlantıları: Connect the appropriate hoses (32mm or 38mm diameter) to the pump's inlet and outlet ports. Ensure all connections are secure and watertight to prevent leaks.
- Astarlama: Before starting, ensure the pump is fully primed with water. This typically involves filling the pump housing with water until it overflows from the suction port.
- Elektrik Bağlantısı: Connect the pump to a grounded electrical outlet (240V). Ensure the circuit is protected by a Residual Current Device (RCD) for safety.
5. Operasyon
Pompa kurulup devreye alındıktan sonra çalışmaya başlayabilirsiniz:
- Pompanın Çalıştırılması: Turn on the power supply to the pump. The pump should start circulating water immediately.
- İzleme: Observe the water flow and pressure. The pump operates quietly, indicating efficient performance.
- Çalışma Süresi: The optimal run time for your pump depends on your pool size and usage. Consult your pool system's guidelines for recommended daily filtration cycles.
- Kapatmak: To turn off the pump, simply disconnect it from the power supply.
6. Bakım
Regular maintenance ensures the longevity and efficiency of your filtration pump:
- Temizlik: Periodically clean the pump's exterior with a damp kumaş. Sert kimyasallar kullanmayın.
- Filter System Maintenance: This pump works in conjunction with a filtration system. Regularly clean or replace the filter cartridges or media as recommended by your filter system's manual.
- Kışlama: If you live in an area with freezing temperatures, disconnect the pump and drain all water from it before winter. Store the pump in a dry, frost-free location.
- Hortum Kontrolü: Regularly check hoses and connections for wear, cracks, or leaks. Replace damaged components as needed.
7. Sorun Giderme
Pompanızla ilgili sorunlarla karşılaşırsanız, aşağıdaki yaygın sorunlara ve çözümlere bakın:
| Sorun | Olası Neden | Çözüm |
|---|---|---|
| Pompa çalışmıyor | Güç kaynağı yok Motor aşırı ısınıyor Pervane sıkışmış | Güç bağlantısını ve devre kesiciyi kontrol edin Allow pump to cool down Disconnect power and inspect/clear impeller |
| Düşük su akışı | Pompa doldurulmamış Tıkalı filtre Emiş hattında hava kaçağı | Pompayı yeniden çalıştırın Filtreyi temizleyin veya değiştirin Check all suction line connections for tightness |
| Pompa gürültülü | Sistemde hava var Pervanedeki pislik Pompa kuru çalışıyor | Sistemdeki havayı boşaltın Disconnect power and clear debris Ensure pump is primed and has continuous water supply |
8. Özellikler
| Özellik | Şartname |
|---|---|
| Üretici | Steinbach |
| Model Numarası | 040955 |
| Ürün Boyutları (U x G x Y) | 22.5 x 15.5 x 33.5 cm (8.86 x 6.1 x 13.19 inç) |
| Ağırlık | 4 kg (8.82 lbs) |
| Akış Hızı | 6000 l/h (75 Liters per minute) |
| Max. Head Height | 6.5 metre |
| Cilttage | 240 Volt |
| Güç Tüketimi | 200 Watt |
| Malzeme | Plastik |
| Renk | Siyah, Gümüş |
| Hortum Bağlantı Çapı | 32mm / 38mm |
| Maks. Su sıcaklığı | 35 ℃ |
| Sertifikasyon | Sertifikalı hayal kırıklığı yok |
| Uluslararası Makale Kodu | 9008748409551 |
9. Garanti ve Destek
Specific warranty information for the Steinbach 040955 CPS 40-2 Filtration Pump is not explicitly provided in the product data. For any product-related inquiries, technical support, or warranty claims, please contact Steinbach customer service directly or refer to the official Steinbach webAyrıntılı destek bilgileri için siteyi ziyaret edin.
Please retain your proof of purchase for any warranty-related matters.