Aiphone JF-2HD

Aiphone JF-2HD Sub-Master Station User Manual

JF Series Audio/Video Intercom System

1. Giriş

The Aiphone JF-2HD Sub-Master Station is designed to extend the capabilities of an Aiphone JF Series audio/video intercom system. This unit allows for door-answering and communication from multiple rooms or a larger area within a building, complementing the main master station. It integrates seamlessly into existing JF Series installations to enhance communication and security.

2. Güvenlik Bilgileri

Please read and understand all safety instructions before installing or operating the JF-2HD Sub-Master Station. Failure to follow these instructions may result in injury, damage to the product, or voiding of the warranty.

  • Elektriksel Güvenlik: Always disconnect power to the intercom system at the circuit breaker before performing any installation, wiring, or maintenance.
  • Profesyonel Kurulum: Kurulum, tüm yerel elektrik yönetmeliklerine ve kurallarına uygun olarak, yetkili personel tarafından gerçekleştirilmelidir.
  • Çevresel Koşullar: Do not expose the unit to moisture, rain, or extreme temperatures. Operate within the specified temperature and humidity ranges.
  • Bileşen Uyumluluğu: Use only specified wiring and components compatible with the Aiphone JF Series system.
  • Havalandırma: Aşırı ısınmayı önlemek için ünitenin etrafında yeterli havalandırma olduğundan emin olun. Havalandırma açıklıklarını hiçbir şekilde kapatmayın.

3. Paket İçeriği

Aşağıda listelenen tüm öğelerin pakette mevcut olduğunu doğrulayın:

  • Aiphone JF-2HD Sub-Master Station
  • Seçenek konektörü
  • Release connector
  • Montaj donanımı
  • Talimatlar (bu kılavuz)

4. Kurulum ve Kurulum

The JF-2HD sub-master station is designed for surface mounting. Follow these steps for proper installation:

  1. Montaj Yeri: Select a suitable indoor location for the sub-master station. It can be installed using a standard single-gang box or ring.
  2. Kablolama: Connect the sub-master station to the master station using compatible wiring. For distances up to 165 feet (50 meters), use 22 AWG wire. For distances up to 330 feet (100 meters), use 18 AWG wire. Aiphone 871804 wire (sold separately) is compatible. Refer to the wiring diagram provided with your master station for specific connection points.
  3. Güvenli Bağlantılar: Kısa devreleri önlemek için tüm kablo bağlantılarının sağlam ve uygun şekilde yalıtılmış olduğundan emin olun.
  4. Ünitenin Montajı: Secure the JF-2HD unit to the wall using the provided mounting hardware.
  5. Güç Restorasyonu: Once all connections are made and the unit is securely mounted, restore power to the intercom system at the circuit breaker.
Aiphone JF-2HD Sub-Master Station front view

Resim 1: Ön view of the Aiphone JF-2HD Sub-Master Station, showing the display and control buttons.

5. Kullanım Talimatları

The JF-2HD Sub-Master Station provides various functions for communication and access control within your intercom system.

  • Çağrıları Cevaplama: When an incoming call is received from the door station, the 3.5-inch LCD color monitor activates, displaying the visitor. To answer, you can either press and hold the answering button for push-to-talk communication or tap the answering button for hands-free communication.
  • İzleme: Press the monitor button at any time to view video and listen to audio from the door station without initiating a call.
  • Kapı Açma: The door-release button activates an electric strike (sold separately) to remotely unlock the entrance for a visitor. If two door stations are connected to the system with an Aiphone RY-3DL adapter (sold separately), you can select which connected door to release.
  • Image Recording: The sub-master operator can record images from the monitor onto the master station's internal memory. Up to 50 images can be recorded at a time, with each image containing 8 frames captured over 8 seconds. Up to 10 images can be saved permanently to the master station's memory.
  • Audio Memos: Access audio memos for internal reminders or replay audio recordings saved on the master station through the door station when personal communication is not possible or preferred.
  • Ses Ayarı: Adjust the chime and audio volume using the dedicated controls on the unit.
  • Communication with Master Station: Press the call button to initiate audio communication with the connected master station.

6. Bakım

Proper maintenance ensures the longevity and optimal performance of your JF-2HD Sub-Master Station.

  • Temizlik: Clean the unit's exterior with a soft, dry cloth. Do not use abrasive cleaners, solvents, or chemical sprays, as these can damage the finish or internal components.
  • Denetleme: Cihazı periyodik olarak hasar veya gevşek bağlantı belirtileri açısından kontrol edin.
  • Havalandırma: Ensure that any ventilation openings are clear of dust and debris to prevent overheating.

7. Sorun Giderme

If you encounter issues with your JF-2HD Sub-Master Station, refer to the following common problems and solutions:

  • Video Gösterimi Yok:
    • Check the power supply to the entire intercom system.
    • Verify all wiring connections between the sub-master station, master station, and door station.
    • Ensure the monitor button is pressed if you are attempting to view video without an incoming call.
  • Ses Yok:
    • Check the volume settings on the sub-master station.
    • Verify all audio wiring connections.
  • Kapı Açma Mekanizması Çalışmıyor:
    • Confirm that the electric strike is correctly installed and wired to the system.
    • Check connections to the RY-3DL adapter if used for multiple door stations.
    • Ensure the door release button is being pressed correctly.
  • Ünite Açılmıyor:
    • Verify the power source and all electrical connections to the intercom system.
    • Check the circuit breaker for the system.

If these steps do not resolve the issue, please contact Aiphone customer support or a qualified technician.

8. Özellikler

ÖzellikŞartname
Model NumarasıJF-2HD
Genel Boyutlar (Y x G x D)7 x 5-5 / 16 x 1-1/4 inç (179 x 135 x 32 mm)
Görüntülemek3.5-inch LCD Color Monitor
Ekran DilleriDutch, English, French, German, Spanish
Maximum Door Distance (Master/Sub-Master)165 ft. (22 AWG wire), 330 ft. (18 AWG wire)
Compatible Wires (Master to Sub-Master)Aiphone 871804 (sold separately)
Konut MalzemesiABS Plastik
Montaj TipiYüzey Montajı
Güç KaynağıCorded Electric (via system power supply)
Ürün Ağırlığı1.35 pound
ÜreticiAIPHONE İLETİŞİM

9. Garanti ve Destek

The Aiphone JF-2HD Sub-Master Station is covered by a standard manufacturer's warranty. For detailed information regarding warranty terms, conditions, and duration, please refer to the warranty card included with your product or visit the official Aiphone webalan.

For technical support, troubleshooting assistance, or service inquiries, please contact Aiphone customer service. Contact information can typically be found on the Aiphone official website or in the documentation provided with your complete JF Series intercom system.

Aiphone meets International Organization for Standardization (ISO) standards 9001 and 14001.