CyberPower EC650LCD

CyberPower EC650LCD Ekolojik Akü Yedekleme ve Aşırı Gerilim Koruyucu UPS Sistemi Kullanım Kılavuzu

Model: EC650LCD | Brand: CyberPower

1. Ürün Bittiview

The CyberPower EC650LCD Ecologic Battery Backup & Surge Protector UPS System is designed to provide reliable power protection for your electronic devices. It features a compact design and incorporates energy-saving technologies to reduce power consumption.

Temel Özellikler:

CyberPower EC650LCD UPS System front view

Şekil 1: Ön view of the CyberPower EC650LCD UPS System, showing the LCD panel and outlets.

2. Güvenlik Bilgileri

Please read and follow all safety instructions carefully before installing, operating, or servicing the UPS system. Failure to do so may result in electric shock, fire, or serious injury.

3. Kurulum

3.1 İlk Şarj

Before initial use, the UPS must be connected to a grounded AC outlet and charged for at least 8 hours to ensure optimal battery performance. The unit will automatically charge when plugged in.

3.2 Cihazları Bağlama

Identify the types of outlets on your UPS:

Plug your devices into the appropriate outlets. Ensure the total load does not exceed the UPS's capacity (390W).

CyberPower EC650LCD UPS System with labels for battery backup and surge protected outlets

Şekil 2: Üst view of the UPS showing the layout of battery-supported and surge-protected outlets.

3.3 USB İletişim Portu

Connect the included USB cable from the UPS to your computer's USB port. This enables communication between the UPS and your computer, allowing for automatic shutdown during extended power outages and monitoring via the PowerPanel Personal Edition software.

CyberPower EC650LCD UPS System with USB port and circuit breaker reset button

Şekil 3: Yan view of the CyberPower EC650LCD UPS, showing the USB communication port and circuit breaker reset button.

4. Kullanım Talimatları

4.1 Açma/Kapatma

4.2 LCD Ekran ve Kontroller

The multifunction LCD panel provides real-time status of the UPS. Use the MODE button to cycle through different display screens:

4.3 ECO Modunun Çalışması

The ECO mode helps conserve energy. When the UPS detects that the computer connected via USB is off or in sleep mode, it will automatically cut power to the peripherals plugged into the ECO controlled outlets. This reduces phantom load and lowers energy costs.

To enable or disable ECO mode, refer to the PowerPanel Personal Edition software settings.

Video 1: Official CyberPower Systems Direct video demonstrating the features and benefits of the CyberPower Ecologic UPS Series, including ECO mode and power protection.

5. Bakım

5.1 Pil Değişimi

The UPS battery is designed for a lifespan of approximately 3-5 years under normal operating conditions. When the battery needs replacement, the UPS may indicate this via an alarm or the LCD display. To replace the battery:

  1. Turn off the UPS and disconnect it from the AC power outlet.
  2. Tüm bağlı cihazların bağlantısını kesin.
  3. Locate the battery compartment on the bottom of the UPS.
  4. Remove the screw securing the battery cover and slide it off.
  5. Akü terminallerini dikkatlice ayırın ve eski aküyü çıkarın.
  6. Insert the new battery (ensure it is a compatible sealed lead-acid battery) and connect the terminals securely.
  7. Pil kapağını yerine takın ve vidayla sabitleyin.
  8. Plug the UPS back into the AC outlet and allow it to charge for 8 hours.
CyberPower EC650LCD UPS System with battery compartment visible on the underside

Şekil 4: Alt taraf view of the CyberPower EC650LCD UPS, showing the battery compartment access.

5.2 Temizlik

Regularly clean the exterior of the UPS with a dry, soft cloth. Do not use liquid or aerosol cleaners. Ensure ventilation openings are free from dust and debris.

6. Sorun Giderme

If the UPS is not functioning correctly, refer to the following common issues and solutions:

SorunOlası NedenÇözüm
UPS açılmıyor.Battery is low or discharged; UPS is not connected to AC power.Connect to AC power and charge for 8 hours. Ensure the power button is pressed and held for 2 seconds.
UPS beeps continuously or shows overload.Too many devices connected; short circuit in a connected device.Disconnect non-essential devices to reduce load. Check connected devices for faults.
Kısa pil ömrü.Battery is old or not fully charged; excessive load.Charge the battery for 8 hours. Reduce the number of connected devices. Consider battery replacement if old.
ECO mode not functioning.USB cable not connected; PowerPanel software not installed or configured.Ensure USB cable is connected. Install and configure PowerPanel Personal Edition software.

If the issue persists after attempting these solutions, please contact CyberPower customer support.

7. Özellikler

ÖzellikDetay
Model NumarasıEC650LCD
Kapasite (VA/Watt)650VA / 390W
Çıktı TürüSimüle Sinüs Dalgası
Mağaza Sayısı8 (4 Battery Backup & Surge, 4 Surge Only - 3 ECO Controlled)
Giriş Voltage120 Volt
Pil TürüSealed Lead Acid (1 x 12V)
Boyutlar (D x G x Y)5.9"D x 10.6"G x 3.1"Y
Ürün Ağırlığı6.4 pound

8. Garanti ve Destek

The CyberPower EC650LCD UPS System comes with a 3 Yıllık Garanti, which includes coverage for the batteries. Additionally, it is backed by a 100,000 Dolarlık Bağlantılı Ekipman Garantisi, providing financial protection for equipment connected to the UPS in the event of damage due to a power surge while properly connected.

Teknik destek, garanti talepleri veya daha fazla yardım için lütfen resmi CyberPower web sitesini ziyaret edin. website or contact their customer service department. You can also download the FREE PowerPanel Personal Edition Management Software from their website for advanced monitoring and control features.

İlgili Belgeler - EC650LCD

Önview CyberPower UPS User Manual: EC450G, EC550G, EC750G, EC650LCD, EC850LCD
Comprehensive user manual for CyberPower Ecologic series UPS systems, covering installation, operation, features like ECO mode, troubleshooting, technical specifications, and warranty information.
Önview CyberPower Ecologic UPS Series User Manual
User manual for CyberPower Ecologic UPS Series (EC450G, EC550G, EC750G, EC650LCD, EC850LCD) providing installation, operation, safety, troubleshooting, and technical specifications for power protection.
Önview CyberPower EC350G/EC550G/EC750G EC650LCD/EC850LCD Kullanım Kılavuzu
CyberPower'ın EC350G, EC550G, EC750G, EC650LCD ve EC850LCD Kesintisiz Güç Kaynağı (UPS) üniteleri için kullanım kılavuzu. Kurulum, çalıştırma, sorun giderme, teknik özellikler ve garanti bilgileri sağlar.
Önview CyberPower BRG1500AVRLCD2 UPS User Manual: Features, Installation, and Operation
Comprehensive user manual for the CyberPower BRG1500AVRLCD2 Intelligent LCD UPS. Learn about its features, installation, basic operation, battery replacement, troubleshooting, and technical specifications.
Önview CyberPower Akıllı UPS Serisi OR1000LCDRM1U/OR1500LCDRM1U Kullanım Kılavuzu | Güç Koruması Kılavuzu
CyberPower Akıllı UPS Serisi (OR1000LCDRM1U, OR1500LCDRM1U) için kapsamlı kullanıcı kılavuzu. Güvenilir güç koruması için kurulum, özellikler, çalışma, akü değişimi, sorun giderme, teknik özellikler ve güvenlik hakkında bilgi edinin.
Önview CyberPower SE450G1, SX650U, SX950U Serisi Bekleme Modu UPS Kullanım Kılavuzu
CyberPower Standby UPS Serisi SE450G1, SX650U ve SX950U modelleri için kapsamlı kullanım kılavuzu. Özellikler, güvenlik uyarıları, kurulum, çalıştırma, sorun giderme, teknik özellikler ve garanti hakkında ayrıntılı bilgi sağlar.