THERMCO ACC3105DIG

Thermco ACC3105DIG Digital Thermometer User Manual

Model: ACC3105DIG

giriiş

The Thermco ACC3105DIG Laboratory Long Stem Digital Thermometer is designed for precise temperature measurements in laboratory and industrial settings. It features a long stem for reaching into various containers and offers high accuracy with a wide temperature range. Each unit is manufactured to exacting standards and comes with a NIST traceable certificate, ensuring reliability and precision.

Ürün Bittiview

Thermco ACC3105DIG Digital Thermometer with white body and red stem

Şekil 1: Thermco ACC3105DIG Digital Thermometer. This image displays the thermometer with a white main body and a long red stainless steel stem. The digital display shows a temperature reading, and control buttons for 'HOLD', 'MAX/MIN', 'ON-OFF', and '°C/°F' are visible on the front panel. The stem is angled downwards from the main unit.

Kurmak

1. Paketten çıkarma

Carefully remove the thermometer from its packaging. Inspect the device for any visible damage. Retain the packaging for future storage or transport.

2. Pil Takılması/Kontrolü

The thermometer is battery-powered. Ensure the battery is correctly installed. If the display does not light up, replace the battery according to the instructions in the Maintenance section.

3. İlk Güç Açma

Basın AÇIK KAPALI button to power on the device. The display should illuminate and show the current temperature.

Kullanım Talimatları

1. Güç Açma/Kapatma

2. Sıcaklık Ölçümü

  1. Insert the stainless steel stem into the substance or environment to be measured. Ensure the stem is sufficiently immersed for accurate readings.
  2. Wait for the temperature reading on the digital display to stabilize. This may take a few seconds depending on the temperature difference.

3. Birim Seçimi (°C/°F)

Basın °C/°F button to switch between Celsius and Fahrenheit temperature units. The selected unit will be indicated on the display.

4. TUTMA Fonksiyonu

Basın TUTMAK button to freeze the current temperature reading on the display. This is useful for recording readings in hard-to-reach areas. Press the TUTMAK Okumayı bırakmak ve canlı ölçüme geri dönmek için düğmeye tekrar basın.

5. MAX/MIN Function

Basın MAKSİMUM/MİNİMUM düğmeye bas view the maximum or minimum temperature recorded since the device was powered on or the function was reset. Subsequent presses will cycle through MAX, MIN, and current temperature display. To reset the MAX/MIN values, typically hold the button down or power cycle the device.

Bakım

1. Temizlik

Wipe the thermometer stem and body with a damp cloth. For sterilization, the stainless steel stem can be cleaned with appropriate laboratory disinfectants. Do not immerse the main body of the thermometer in liquid.

2. Depolama

Store the thermometer in a clean, dry place away from extreme temperatures and direct sunlight. Use the protective sleeve or case if provided.

3. Pil Değişimi

When the display becomes dim or erratic, it's time to replace the battery. Locate the battery compartment, usually on the back or side of the main unit. Open it, remove the old battery, and insert a new one of the same type, observing polarity. Close the compartment securely.

Sorun giderme

SorunOlası NedenÇözüm
Ekran yok veya soluk ekranAkü zayıf veya bitmiş; akü yanlış takılmış.Replace battery; ensure correct polarity.
Yanlış okumalarInsufficient immersion of stem; sensor contamination; extreme environmental conditions.Ensure proper immersion depth; clean the stem; allow thermometer to acclimate to environment.
Düğmeler yanıt vermiyorBattery issue; internal malfunction.Pili değiştirin. Sorun devam ederse, müşteri desteğiyle iletişime geçin.

Özellikler

İlgili Belgeler - ACC3105DIG

Önview Thermco ACCRT8017 Dual Data Logging Thermometer User Manual & Specifications
User manual for the Thermco ACCRT8017 Dual Data Logging Thermometer. Features dual probes, high accuracy, large data logging capacity (24 million readings), user-configurable alarms, and CSV data format for fridge and freezer monitoring.
Önview THERMCO ACCRT8019UL Dual Data Logging Thermometer - Ultra Low Freezer
Detailed specifications, features, and operating instructions for the THERMCO ACCRT8019UL Dual Data Logging Thermometer. This device monitors ultra-low freezers with dual probes, offers SD card data logging, and user-configurable alarms.
Önview McKesson Üçlü Ekranlı Buzdolabı/Dondurucu Termometresi | MCK895RFV
McKesson Üçlü Ekranlı Tek Problu Büyük Haneli Buzdolabı/Dondurucu Termometresi (MCK895RFV) hakkında özellikler, teknik özellikler, çalışma ve alarm ayarları dahil ayrıntılı bilgiler. NIST izlenebilir.
Önview AccuTherm™ CARE4U Alın Kızılötesi Termometresi Kullanım Kılavuzu ve Teknik Özellikler
AccuTherm™ CARE4U Klinik Alın Kızılötesi Termometresi'nin kullanım talimatlarını, ölçüm kılavuzunu, bakımını, önlemlerini ve teknik özelliklerini kapsayan kapsamlı kılavuzu. AccuTherm termometrenizi nasıl kullanacağınızı ve bakımını nasıl yapacağınızı öğrenin.
Önview McKesson Buzdolabı/Dondurucu Termometresi ÇİFT PROB MCK8100MATB Kullanım Kılavuzu
McKesson Buzdolabı/Dondurucu Termometresi ÇİFT PROB (MCK8100MATB) için ayrıntılı kullanım kılavuzu. Özellikler, teknik özellikler, kurulum talimatları, ayar yapılandırması ve sorun giderme notlarını içerir.
Önview Thermco ACC895WRFT Wireless Min-Max Alarm Thermometer User Manual
User manual for the Thermco ACC895WRFT Wireless Min-Max Alarm Thermometer. Features include 3-channel measurement, programmable alarms, ambient/external/wireless temperature display, and a foldaway stand. Includes installation, operation, troubleshooting, and specifications.