Linear 212LS-C26DCR-RT

Linear 212LS-C26DCR-RT Electronic Access Control Cylindrical Lockset User Manual

Model: 212LS-C26DCR-RT

1. Giriş

This manual provides instructions for the installation, operation, and maintenance of the Linear 212LS-C26DCR-RT Electronic Access Control Cylindrical Lockset. This lockset is designed for secure access control in both commercial and residential environments.

Temel Özellikler:

  • Uzun kullanım ömrü için dayanıklı yapı.
  • Clutch lever design for enhanced security.
  • Long battery life (up to 15,000 keypad activations) with low-battery alert.
  • Password retention during battery removal.
  • Easy installation into standard cylindrical door preps (ANSI 151.8).
  • Master password control system for managing up to 120 user passwords.
  • Mechanical key override for emergency situations.

2. Güvenlik Bilgileri

Please read all instructions carefully before installation and operation. Failure to follow these instructions may result in damage to the product, property, or personal injury.

  • Ensure proper battery polarity when installing batteries.
  • Do not expose the lockset to extreme temperatures or moisture beyond its intended operating conditions.
  • Keep mechanical keys in a secure location, separate from the lockset.
  • Do not attempt to disassemble or repair the lockset yourself. Refer to qualified personnel for service.

3. Paket İçeriği

Kuruluma başlamadan önce tüm öğelerin mevcut olduğundan emin olun:

  • Linear 212LS-C26DCR-RT Electronic Access Control Cylindrical Lockset
  • Montaj donanımı
  • 2 Mechanical keys
  • Kullanım Kılavuzu (bu belge)

Note: Four AA 1.5 volt batteries are required and are not included in the package.

4. Kurulum

The lockset is designed for easy installation into a standard cylindrical door preparation (ANSI 151.8).

4.1. Kapıyı Hazırlayın

Ensure your door has a standard cylindrical door prep. If not, consult a professional for proper door preparation.

4.2. Install the Lockset

  1. Follow the detailed instructions provided with the mounting hardware to secure the lockset components to the door.
  2. Ensure all cables are properly connected and routed to avoid pinching.

4.3. Pilleri Takın

  1. Locate the battery compartment, typically on the interior side of the lockset.
  2. Insert four (4) AA 1.5 volt batteries, ensuring correct polarity.
  3. Pil bölmesi kapağını sıkıca kapatın.

Linear 212LS-C26DCR-RT Electronic Access Control Cylindrical Lockset, Right Hand OpeningFigure 1: Linear 212LS-C26DCR-RT Lockset showing keypad and lever handle.

5. Operasyon

The lockset operates using a keypad for electronic access or mechanical keys for override.

5.1. Initial Setup and Master Password

Upon initial power-up, you will need to set a master password. Refer to the specific programming instructions included with your lockset for this procedure. The master password allows for the management of up to 120 individual user passwords.

5.2. Adding User Passwords

Using the master password, you can add or delete up to 120 unique user passwords. Each user password grants access through the keypad.

5.3. Keypad Entry

  1. Enter a valid user password on the keypad.
  2. The lock will disengage, allowing the handle to operate.
  3. If an incorrect code is entered, the handle will not mechanically engage the cylinder, preventing unauthorized entry.

5.4. Mekanik Anahtar Geçersiz Kılma

In emergency situations or if batteries are depleted, the provided mechanical keys can be used to unlock the door. Insert the key into the keyway and turn to unlock.

6. Bakım

6.1. Pil Değişimi

The lockset is designed for approximately 15,000 keypad activations, which translates to about 5 years of usage based on 10 activations per day. A low-battery alert will indicate when batteries need replacement. Replace all four AA batteries simultaneously with new, high-quality alkaline batteries.

6.2. Temizlik

Clean the lockset exterior with a soft, damp Bez kullanın. Yüzeye veya elektronik bileşenlere zarar verebilecek aşındırıcı temizleyicilerden veya çözücülerden kaçının.

7. Sorun Giderme

SorunOlası NedenÇözüm
Handle does not engage after entering correct code.Low batteries or mechanical issue.Replace batteries. If problem persists, use mechanical key and contact support.
Tuş takımı yanıt vermiyor.Dead batteries or internal electronic fault.Replace batteries. If still unresponsive, use mechanical key and contact support.
Cannot add or delete user passwords.Incorrect master password or programming error.Verify master password. Refer to programming instructions for correct procedure.

8. Özellikler

ÖzellikDetay
Model Numarası212LS-C26DCR-RT
Boyutlar (U x G x Y)10.1 x 8.5 x 7.4 inç
Ağırlık5.5 Pound
Güç Kaynağı4 AA 1.5V batteries (not included)
Pil ÖmrüApprox. 15,000 activations
Kilit TipiTuş takımı
Özel ÖzellikSu geçirmez
MalzemeMetal

9. Garanti ve Destek

This product typically comes with a manufacturer's warranty. Please refer to the warranty card included with your purchase for specific terms and conditions. For technical support, troubleshooting assistance, or to inquire about replacement parts, please contact Linear customer service. Contact information can usually be found on the manufacturer's websitede veya ürün ambalajında ​​yer almamaktadır.

Note: The warranty period for this product is generally 24 months, primarily for wholesale purchasers. Please confirm your specific warranty coverage.

İlgili Belgeler - 212LS-C26DCR-RT

Önview Linear AK-11 Digital Keyless Entry System Installation and Programming Manual
The Linear AK-11 is a robust digital keyless entry system designed for access control applications. It features a durable cast aluminum enclosure, supports up to 480 programmable entry codes (1-6 digits), and offers multiple output options including two relays and two solid-state outputs. This system is ideal for controlling access to doors and gates, providing features like anti-passback, keypad lockout, and various input functionalities for enhanced security and convenience.
Önview Linear AK-11 Digital Keyless Entry System Installation and Programming Instructions
Comprehensive guide for installing and programming the Linear AK-11 Digital Keyless Entry System, covering features, specifications, wiring, setup, operation, and troubleshooting.
Önview Linear Entry Pro Series Installation Manual: Hardware and System Setup
This manual provides comprehensive installation, wiring, and configuration guidance for the Linear Entry Pro Series Telephone Entry and Access Control Systems (EP-4xx, EP-7xx). It details hardware features, component locations, system diagnostics, troubleshooting, and specifications for secure access management.
Önview Linear AccessKey AK-1 Digital Keypad Entry System - Technical Specifications and Features
Detailed information on the Linear AccessKey AK-1, a digital keypad entry system for commercial access control, featuring rugged design, multiple outputs, and programmable PIN codes.
Önview Doğrusal Kablosuz Giriş Sistemleri: Tuş Takımları ve Kontrol Cihazları
Konut, ticari ve endüstriyel uygulamalarda güvenli erişim kontrolü için MDKP tuş takımları, AP-5 kontrolörleri ve çeşitli AK serisi tuş takımları dahil olmak üzere Linear'ın kablosuz giriş sistemleri yelpazesini keşfedin.
Önview Linear AM/II Wireless Access Control System: Installation & Programming Guide
Comprehensive installation and programming instructions for the Linear AM/II Wireless Access Control System, covering features, setup, and operation. Learn about its wireless capabilities, Wiegand/RS-232 interfaces, and networking options.