1. Ürün Bittiview
The AmScope B490 is a compound binocular microscope designed for biological and educational applications, offering high magnification and clear imaging. It features a sliding head for adjustable interpupillary distance, 10x widefield eyepieces, and a forward-facing nosepiece with four DIN achromatic objectives (4x, 10x, 40xS, 100xS oil). Illumination is provided by Brightfield halogen light with a rheostat for intensity control, paired with a 1.25 NA Abbe condenser and iris diaphragm. The microscope includes a double-layer mechanical stage iletage stop and graduated coarse and fine focus with tension control.

Figure 1: AmScope B490 Compound Binocular Microscope, front-side view.
Dahil Bileşenler:
- Çift katmanlı mekanik s'li AmScope B490 mikroskoptage
- 10x widefield eyepieces (one pair)
- 4x DIN akromatik objektif
- 10x DIN akromatik objektif
- 40xS DIN achromatic objective
- 100xS (oil) DIN achromatic objective
- Immersion oil (one bottle)
- Color filters (blue and green)
- Spare halogen bulb
- Yedek sigorta
- Kullanım kılavuzu

Figure 2: Included accessories: eyepieces, objectives, immersion oil, color filters, spare bulb, and fuse.
2. Kurulum Talimatları
- Paketin açılması: Tüm parçaları ambalajından dikkatlice çıkarın. İlerideki taşıma veya saklama için orijinal ambalajı saklayın.
- Atama: Mikroskobu, doğrudan güneş ışığından, aşırı ısıdan, tozdan ve titreşimlerden uzak, sabit ve düz bir yüzeye yerleştirin.
- Kafa Düzeneği: Loosen the head retaining screw on the microscope body. Gently insert the binocular head into the top opening, ensuring it is fully seated. Tighten the retaining screw to secure the head.
- Göz merceği montajı: Remove the protective caps from the eyepiece tubes and the eyepieces. Insert the two WF10x eyepieces into the binocular head's eyepiece tubes.
- Amaçlanan Kurulum: Rotate the revolving nosepiece until the 4x objective is positioned over the stage opening. Install the remaining objectives (10x, 40xS, 100xS oil) clockwise into the nosepiece.
- Güç Bağlantısı: Ensure the power switch is in the 'OFF' position. Connect the power cord to the microscope's power input and then to a suitable electrical outlet (110V).

Şekil 3: Yan view of the microscope, showing focus knobs and power input location.
3. Kullanım Talimatları
3.1 Power and Illumination
- Turn on the main power switch located on the base of the microscope.
- Adjust the illumination intensity using the rheostat knob on the side of the base. Start with a lower intensity and increase as needed for comfortable viewIng.
3.2 Specimen Placement
- Rotate the revolving nosepiece to select the lowest power objective (4x).
- s'yi yükseltintage using the coarse focus knob to create enough space to place the specimen slide.
- S'yi açtage clips on the mechanical stage and carefully place the specimen slide, securing it with the clips.
- XY'leri kullanıntage control knobs to position the desired area of the specimen directly under the objective lens.

Şekil 4: Ön view of the microscope, highlighting the mechanical stage and objectives.
3.3 Focusing and Magnification
- Gözbebekleri Arası Mesafe: While looking through the eyepieces, adjust the sliding head to match your eye distance until a single, circular field of view is observed. The range is 55 to 75mm.
- Dioptrik Ayar: If one eye is stronger than the other, use the diopter adjustment ring on one eyepiece to compensate, ensuring both eyes are in focus.
- Kaba Odak: Slowly lower the stage using the coarse focus knob until the specimen comes into rough focus.
- İnce Odak: Use the fine focus knob for precise focusing and to achieve a sharp image.
- Hedeflerin Değiştirilmesi: To increase magnification, rotate the revolving nosepiece clockwise to the next objective (e.g., from 4x to 10x). Due to the parfocal design, only minor fine focus adjustments should be needed.
- Using 100xS Oil Immersion Objective: When using the 100xS objective, apply a small drop of immersion oil directly onto the specimen slide in the area to be viewed. Carefully lower the 100xS objective into the oil drop until it makes contact. Focus using the fine focus knob only. Always clean the 100xS objective and slide immediately after use to prevent oil from drying.

Şekil 5: Yakın çekim view of the objectives and mechanical stage.
3.4 Condenser and Iris Diaphragm Adjustment
- The 1.25 NA Abbe condenser is mounted on a rack-and-pinion system, allowing its height to be adjusted. Raise or lower the condenser to optimize illumination for different objectives.
- The iris diaphragm lever controls the aperture of the light beam. Adjust it to achieve optimal contrast and resolution for the specimen and objective in use. Generally, a smaller aperture increases contrast but reduces resolution, while a larger aperture increases resolution but reduces contrast.
4. Bakım
4.1 Temizlik
- Optik Bileşenler: Use only specialized lens cleaning paper and lens cleaning solution. Gently wipe lenses in a circular motion. Avoid touching optical surfaces with bare hands.
- Vücut: Clean the microscope body with a soft, damp bez. Sert kimyasallar veya solventler kullanmaktan kaçının.
- Daldırma Yağı: After using the 100xS oil immersion objective, immediately clean the objective lens and the specimen slide with lens cleaning solution to prevent oil residue from hardening.
4.2 Ampul Değişimi
If the halogen illumination fails, the bulb may need replacement. Ensure the microscope is unplugged and the bulb has cooled before attempting replacement. Refer to the diagram in the original packaging for specific bulb access. Use the provided spare halogen bulb (6V/20W).
4.3 Sigorta Değişimi
If the microscope does not power on, check the fuse. Ensure the microscope is unplugged. The fuse holder is typically located near the power input. Replace with the provided spare fuse of the correct rating.
4.4 Depolama
When not in use, cover the microscope with a dust cover to protect it from dust and debris. Store in a cool, dry place. The anti-mold surfaces help preserve optics in high-humidity environments, but proper storage is still recommended.
5. Sorun Giderme
| Sorun | Olası Neden | Çözüm |
|---|---|---|
| Aydınlatma yok | Power cord disconnected, power switch off, bulb burnt out, fuse blown | Check power connection, turn on switch, replace bulb, replace fuse |
| Görüntü bulanık/odak dışı. | Incorrect focus, objective not fully engaged, dirty lenses, incorrect interpupillary distance/diopter setting | Adjust coarse/fine focus, rotate nosepiece until objective clicks into place, clean lenses, adjust interpupillary distance/diopter |
| Insufficient contrast | Iris diaphragm too open, condenser height incorrect | Adjust iris diaphragm to a smaller aperture, adjust condenser height |
| Tarladaki koyu lekeler view | Dust on eyepieces or objectives, dirty specimen slide | Clean eyepieces, objectives, and specimen slide |
| Stage not moving smoothly | Stage lock engaged, debris in mechanism | emin oluntage lock is disengaged, clean stage area (consult professional if persistent) |
6. Özellikler
| Özellik | Şartname |
|---|---|
| KAFA | Compound Binocular, Sliding Head, 30-degree inclination, 360-degree rotation |
| Göz mercekleri | WF10x |
| Amaçlar | 4x, 10x, 40xS (spring), 100xS (spring, oil) DIN Achromatic |
| Büyütme Aralığı | 40X-1000X |
| Stage | Çift Katmanlı Mekanik Stage (140 x 140mm), 75 x 45mm traveling range, 1mm divisions, Stage Stop |
| Odaklanma | Coaxial Coarse and Fine Focus, 30mm focusing range, 0.002mm fine-focus divisions, Tension Control |
| Aydınlatma | Transmitted (lower) Brightfield Halogen with Rheostat (6V/20W) |
| Kondansatör | 1.25 NA Abbe Condenser with Iris Diaphragm, Rack-and-Pinion Control |
| Göz bebekleri arası mesafe | 55-75 mm |
| Güç | 110V (US standard) |
| Boyutlar (Y x G x D) | 16 x 9 x 12 inç (yaklaşık) |
| Ağırlık | 15.32 pound (yaklaşık) |
| Malzeme | Solid-metal enamel-coated body, optical glass components |
| Özel Özellikler | Anti-mold surfaces |
7. Garanti ve Destek
For warranty information, technical support, or service inquiries, please refer to the official AmScope website or contact AmScope customer service directly. Details regarding specific warranty periods and support procedures are typically provided with your purchase documentation or on the manufacturer's official channels.
Manufacturer: AmScope
Headquarters: Irvine, CA, USA