SENSOR SWITCH MP 20

MP20 Güç Paketi Kullanım Kılavuzu

Modeli: MP 20 | Marka: SENSÖR ANAHTARI

1. Giriş

The SENSOR SWITCH MP20 Power Pack is a robust and reliable device designed to provide power and control for occupancy sensor systems. This power pack operates at 120/277VAC and can handle up to 20 amps, making it suitable for various commercial and industrial lighting control applications. It is engineered to be compatible with occupancy sensors, including those from different brands, offering flexibility in system integration. The MP20 is UL 2043 Plenum Rated, ensuring its suitability for use in air-handling spaces.

2. Güvenlik Bilgileri

WARNING: Risk of electric shock. Installation should only be performed by a qualified electrician in accordance with all national and local electrical codes.

3. Kurulum ve Kurulum

The MP20 Power Pack is designed for easy integration into existing or new lighting control systems. Follow these steps for proper installation:

  1. Güç Bağlantısının Kesilmesi: Before beginning any wiring, ensure that power to the circuit is completely disconnected at the main breaker.
  2. Montaj: Mount the MP20 Power Pack securely in a suitable junction box or electrical enclosure. Ensure adequate ventilation.
  3. Kablo Bağlantıları: Refer to the wiring diagram below and the label on the device for precise connections. All connections must be made using appropriate wire nuts or connectors and insulated properly.
    • BLACK Wire: Connect to 120 VAC Line.
    • ORANGE Wire: Connect to 277 VAC Line (if using 277V system). If using 120V, cap and insulate this wire.
    • WHITE Wire: Nötr noktaya bağlanın.
    • BLUE Wires (2): These are Relay Contacts. Connect to the load (e.g., lighting fixtures).
    • RED Wire (Class 2): Connect to 15 VDC output from the occupancy sensor.
    • WHITE Wire (Class 2): Connect to Sensor input from the occupancy sensor.
    • BLACK Wire (Class 2): Connect to Common from the occupancy sensor.
  4. Güvenli Bağlantılar: Double-check all wiring connections for tightness and proper insulation.
  5. Gücü Geri Yükle: Once all connections are secure and the device is properly mounted, restore power to the circuit.
SENSOR SWITCH MP20 Power Pack with wiring

Figure 1: SENSOR SWITCH MP20 Power Pack. This image displays the compact black rectangular device with various colored wires extending from its sides, including black, white, blue, orange, and red wires. The product label is clearly visible, detailing the model number, voltage, amperage, and specific wiring instructions for both line voltage and Class 2 low voltage bağlantıları.

4. Operasyon

The MP20 Power Pack operates in conjunction with an external occupancy sensor. Once properly wired and powered, the power pack will respond to signals from the connected sensor. When the occupancy sensor detects presence, it will signal the MP20 to close its internal relay contacts, thereby supplying power to the connected load (e.g., lights). When the sensor no longer detects presence and its programmed delay expires, it will signal the MP20 to open its relay contacts, turning off the load.

The power pack provides the necessary low-voltage power (15 VDC) to the connected occupancy sensor, eliminating the need for a separate power supply for the sensor.

5. Bakım

The SENSOR SWITCH MP20 Power Pack is designed for maintenance-free operation. However, periodic inspection is recommended to ensure optimal performance:

6. Sorun Giderme

If the MP20 Power Pack is not functioning as expected, consider the following troubleshooting steps:

If issues persist after performing these checks, contact customer support or a qualified electrician.

7. Özellikler

BağlanmakDeğer
Model NumarasıMP 20
Giriş Voltage120 / 277 VAC
Maksimum Akım20 Amps
Çıkış Hacmitage (Class 2)15 VDC
Boyutlar (U x G x Y)3 x 1.8 x 3 inç
Ağırlık9.6 ons
DerecelendirmeUL 2043 Plenum Rated, UL Listed 3D62, cCSAus File #229654
Kullanım OrtamıSadece İç Mekanda Kullanılabilir
ÜreticiSENSÖR ANAHTARI

8. Garanti ve Destek

For specific warranty information regarding the MP20 Power Pack, please refer to the documentation provided with your purchase or contact SENSOR SWITCH directly. Warranty terms and conditions may vary.

For technical support, product inquiries, or further assistance, please contact SENSOR SWITCH:

İlgili Belgeler - MP 20

Önview SensorSwitch PP20 & SP20 Power Pack Datasheet | Acuity Brands
Teknik özellikler ve üzeriview for the SensorSwitch PP20 and SP20 Power Packs, designed for low voltage sensor systems and lighting load switching. Includes features, warranty, ordering information, and electrical/mechanical specifications.
Önview SensorSwitch PP5 SSA Power/Relay Pack: Features, Specifications, and Wiring
Comprehensive guide to the SensorSwitch PP5 SSA Power/Relay Pack, detailing its features, electrical and mechanical specifications, environmental considerations, warranty, and wiring instructions for lighting control systems.
Önview Acuity Controls MP20/MSP20 Power Relay Pack - Technical Specifications and Wiring
Detailed technical specifications, features, and wiring diagrams for the Acuity Controls MP20 Power Pack and MSP20 Secondary Relay Pack, designed for low voltage occupancy sensor lighting control systems.
Önview Metcalfe MP20 20 Litre Ağır Hizmet Tipi Tezgah Üstü Mikser: Kurulum ve Kullanım Talimatları
Metcalfe MP20 20 Litre Ağır Hizmet Tipi Tezgah Üstü Mikser için kapsamlı kurulum, çalıştırma, temizlik, bakım ve sorun giderme kılavuzu. Teknik özellikler, karıştırma kapasiteleri ve garanti bilgileri içerir.
Önview BOTEX UP-2RF Ünite Paketi RF Kullanım Kılavuzu - Aydınlatma Kontrolü
BOTEX UP-2RF Ünite Paketi RF için kapsamlı kullanıcı kılavuzu, profesyonel aydınlatma kontrolü için özellikleri, çalışma modlarını (DMX Adresi, Anahtar Paketi, Dimmer Paketi) ve teknik özellikleri ayrıntılı olarak açıklamaktadır.
Önview KSTAR BluE-H5/H3 Energy Storage System: Installation, Operation & Maintenance Manual
Comprehensive manual for KSTAR BluE-H5/H3 Energy Storage Systems, including models like BluE-S 5000D and BluE-S 3680D. Covers installation, operation, maintenance, safety, and troubleshooting for DC-coupled, AC-coupled, and hybrid systems.