1. Giriş
This manual provides essential information for the proper installation, operation, and maintenance of the Rheem SP20138 Pilot Assembly. This component is specifically designed as a replacement part for Rheem 22V30FN gas water heaters. The SP20138 is an ultra-low NOx replacement part, ensuring compliance with environmental standards.
2. Güvenlik Bilgileri
UYARI: Yanlış kurulum, ayar, değişiklik, servis veya bakım, maddi hasara, yaralanmaya veya ölüme neden olabilir. Bu ekipmanı kurmadan veya bakımını yapmadan önce kurulum, çalıştırma ve bakım talimatlarını baştan sona okuyun.
- Always turn off the gas supply to the water heater before beginning any work.
- Disconnect electrical power to the water heater if applicable.
- Allow the water heater to cool down before handling components.
- Kurulum ve servis, kalifiye bir kurulumcu, servis acentesi veya gaz tedarikçisi tarafından yapılmalıdır.
- Gazlı cihazlarla çalışırken yeterli havalandırmayı sağlayın.
- Check for gas leaks after installation using a non-corrosive leak detection solution.
3. Ürün Bittiview
The Rheem SP20138 Pilot Assembly is a crucial component responsible for igniting the main burner in your gas water heater. It typically consists of a pilot burner, a thermocouple (or thermopile), and an igniter electrode. This assembly ensures safe and reliable ignition of the main gas flow.

This image displays the Rheem SP20138 Pilot Assembly, a critical component for gas water heaters, specifically designed for the 22V30FN model. It includes the pilot burner, thermocouple, and igniter.
4. Kurulum ve Kurulum
Not: Installation should only be performed by a qualified professional. These instructions are for informational purposes and to guide the professional installer.
- Hazırlık: Ensure the gas supply to the water heater is turned off at the main shut-off valve. Disconnect electrical power if applicable. Allow the water heater to cool completely.
- Erişim: Remove the outer and inner burner access doors to expose the burner assembly and pilot light.
- Eski tertibatı ayırın: Carefully disconnect the gas line to the pilot, the thermocouple/thermopile wiring, and the igniter wire from the existing pilot assembly. Note the routing of all wires and tubing.
- Eski Montajı Kaldır: Unfasten and remove the old pilot assembly from its mounting bracket.
- Yeni Parçayı Takın: Position the new Rheem SP20138 Pilot Assembly into the mounting bracket. Secure it firmly.
- Bileşenleri Bağlayın: Reconnect the gas line to the pilot, ensuring a tight, leak-free connection. Attach the thermocouple/thermopile wiring and the igniter wire to their respective terminals, following the original routing.
- Sızıntı Testi: Turn on the main gas supply. Apply a non-corrosive leak detection solution to all gas connections. Bubbles indicate a leak, which must be corrected immediately.
- Pilot Ateşleme: Follow the water heater's specific instructions for lighting the pilot. This typically involves turning the gas control knob to 'Pilot', pressing it down, and activating the igniter until the pilot flame is established and the thermocouple holds it.
- İşlemi Doğrulayın: Once the pilot is lit, turn the gas control knob to the 'On' position and set the thermostat to call for heat. Observe the main burner ignition. It should ignite smoothly and consistently.
- Yeniden birleştirme: Replace the inner and outer burner access doors.
5. Kullanım Talimatları
The Rheem SP20138 Pilot Assembly operates automatically once properly installed and lit. Its primary function is to provide a continuous small flame (the pilot light) that ignites the main burner when the water heater's thermostat calls for hot water. The thermocouple/thermopile within the assembly senses this pilot flame and generates a small electrical current to keep the gas valve open to the pilot, ensuring safety. If the pilot flame goes out, the thermocouple cools, stopping the current and closing the pilot gas valve, preventing unburned gas from accumulating.
6. Bakım
Regular inspection of the pilot assembly can help ensure reliable operation of your water heater. This should be performed by a qualified technician annually.
- Pilot Alevinin Kontrolü: The pilot flame should be steady, blue, and engulf the tip of the thermocouple/thermopile. A weak, yellow, or flickering flame may indicate a problem.
- Temizlik: Ensure the pilot burner and surrounding area are free from dust, lint, or debris that could obstruct the flame or air supply.
- Bağlantılar: Verify that all gas and electrical connections to the pilot assembly are secure and free from corrosion.
7. Sorun Giderme
If your water heater is not operating correctly, the pilot assembly may be a factor. Always consult a qualified technician for diagnosis and repair.
- Pilot Will Not Light:
- Ensure gas supply is on.
- Check for obstructions in the pilot tube.
- Igniter may be faulty or misaligned.
- Gas control valve may be faulty.
- Pilot Lights But Will Not Stay Lit:
- Thermocouple/thermopile may be faulty, dirty, or improperly positioned. It must be fully engulfed by the pilot flame.
- Pilot flame may be too weak or yellow, not adequately heating the thermocouple.
- Gas control valve may be faulty.
- Main Burner Does Not Ignite:
- Pilot flame may not be strong enough to ignite the main burner.
- Thermostat setting may be too low or faulty.
- Main gas valve may be faulty.
8. Özellikler
| Şartname | Detay |
|---|---|
| Üretici | Rheem |
| Parça Numarası | SP20138 |
| Ürün Model Numarası | SP20138 |
| Uyumluluk | Rheem 22V30FN Water Heaters |
| Ürün Ağırlığı | 1.5 pound |
| Paket Boyutları | 16.9 x 12.4 x 2.3 inç |
| Ürün Paket Miktarı | 1 |
9. Garanti ve Destek
For specific warranty information regarding the Rheem SP20138 Pilot Assembly, please refer to the documentation provided with your original Rheem water heater or contact Rheem customer support directly. Rheem's official website provides comprehensive support resources, including contact information for technical assistance and authorized service providers.
Rheem Resmi Webalan: www.rheem.com