giriiş
This manual provides essential information for the safe and effective use of the Eaton BR250 2" 50 Amp Double Pole Interchangeable Circuit Breaker. This device is designed to protect electrical circuits from overcurrents and short circuits, ensuring the safety of your electrical system and connected appliances. Please read this manual thoroughly before installation or operation.

Resim: Ön taraf view of the Eaton BR250 circuit breaker, showing the 'On/I' and 'Off/O' labels, '50' amp rating, and Eaton branding.
Güvenlik Bilgileri
UYARI: Electrical work can be hazardous. Improper installation or maintenance can result in serious injury or death. Always consult a qualified electrician for installation and service. Ensure power is disconnected at the main service panel before performing any work on electrical circuits.
- Always turn off the main power supply at the circuit breaker panel before installing, removing, or servicing circuit breakers.
- Yalıtımlı eldivenler ve güvenlik gözlükleri gibi uygun kişisel koruyucu ekipman (KKD) kullanın.
- Verify that the circuit breaker rating (ampyaş ve cilttage) matches the requirements of the circuit and load it will protect.
- Hasarlı veya üzerinde değişiklik yapılmış devre kesicileri kullanmayın.
- Aşırı ısınmayı önlemek için tüm bağlantıların sıkı ve güvenli olduğundan emin olun.
Kurulum ve Yükleme
The Eaton BR250 is a plug-in mount, double-pole circuit breaker designed for use in compatible Eaton BR series load centers. Professional installation by a licensed electrician is highly recommended.
- Güç Bağlantısının Kesilmesi: Locate the main service panel and turn off the main breaker to completely de-energize the panel. Verify power is off using a voltage test cihazı.
- Panel Erişimi: Elektrik panosunun kapağını dikkatlice çıkarın.
- Kesici Yerleşimi: Identify an available space in the load center for a 2-inch double-pole breaker. The BR250 is designed to plug directly onto the bus bar.
- Kablolama:
- Connect the two hot wires (typically black and red for 240V circuits) to the screw terminals on the circuit breaker. Ensure the wires are stripped to the correct length and inserted fully into the terminals.
- Tighten the terminal screws to the specified torque. Refer to the breaker's label for torque specifications.
- Connect the neutral wire to the neutral bus bar and the ground wire to the ground bus bar in the panel.
- Montaj: Align the circuit breaker with the bus bar and firmly push it into place until it is securely seated.
- Panelin Yeniden Montajı: Replace the panel cover, ensuring all wires are clear and not pinched.
- Güç Restorasyonu: Ana devre kesiciyi tekrar açın.

Resim: Yakın çekim view of the Eaton BR250 circuit breaker's terminal screws, where electrical wires are connected.

Resim: Ön view of the Eaton BR250 circuit breaker, displaying technical specifications such as Type BR250, C250, 120/240V, Cu/Al #6 Max. Wire, HACR Type, 2 Pole, J-969, E7819-T, LR43556 Disj., and UL Listed mark.
Kullanım Talimatları
The Eaton BR250 circuit breaker features a simple toggle switch for operation.
- AÇMAK için: Açma/kapama kolunu sıkıca "AÇIK/I" konumuna itin.
- Kapatmak: Açma/kapama kolunu sıkıca "OFF/O" konumuna itin.
- Devre Kesici Atması: If an overcurrent or short circuit occurs, the breaker will automatically trip to the center position (between ON and OFF). To reset a tripped breaker, first push the handle completely to the "OFF/O" position, then push it to the "ON/I" position. If the breaker immediately trips again, there is still a fault in the circuit that needs to be addressed by a qualified electrician.
Bakım
Sigortalar genellikle minimum bakım gerektirir. Ancak, güvenli çalışmanın sürekliliğini sağlamak için periyodik muayene önerilir.
- Görsel Muayene: Annually, with the main power off, visually inspect the circuit breaker for any signs of damage, discoloration, or loose connections.
- Panel Temizliği: Keep the electrical panel area clean and free from dust, debris, and obstructions.
- Profesyonel Kontrol: Elektrik panonuzu ve sigortalarınızı birkaç yılda bir kalifiye bir elektrikçiye kontrol ettirmeyi düşünün.
Sorun giderme
| Sorun | Olası Neden | Çözüm |
|---|---|---|
| Sigorta sık sık atıyor. | Aşırı yüklenmiş devre, kısa devre, topraklama hatası veya arızalı cihaz. | Unplug appliances from the circuit. Reset the breaker. If it trips again, consult an electrician. |
| Sigorta sıfırlanmıyor. | Persistent fault in the circuit or a damaged breaker. | Ensure the handle is pushed fully to the OFF position before attempting to reset. If it still won't reset, do not force it; contact an electrician. |
| No power to circuit after resetting breaker. | Main breaker tripped, loose wiring, or internal breaker failure. | Check the main breaker. If it's on, contact a qualified electrician for diagnosis. |
Özellikler
| Özellik | Detay |
|---|---|
| Marka | Yemek |
| Model Adı | Eaton BR250 2" 50 Amp Double Pole Interchangeable Circuit Breaker |
| Parça Numarası | BR250 |
| Güncel Derecelendirme | 50 Amps |
| Cilttage | 240 Volt |
| Kutup Sayısı | 2 |
| Devre Kesici Tipi | Standart |
| Montaj Tipi | Geçmeli Montaj |
| Malzeme | Plastik |
| Ürün Boyutları (LxWxY) | 15 x 1 x 3 inç |
| UPC | 0786676363051 |

Resim: Alt view of the Eaton BR250 circuit breaker, displaying the current interrupting rating of 10,000 Amps and torque specifications for wire connections.

Resim: Arka view of the Eaton BR250 circuit breaker, showing a barcode with UPC 0786676363051 and a label indicating it was 'Assembled in Dominican Republic'.
Garanti Bilgileri
Eaton products are typically covered by a manufacturer's warranty. For specific warranty terms and conditions applicable to your BR250 circuit breaker, please refer to the documentation included with your purchase or visit the official Eaton website. Warranty details may vary by region and product type.
Müşteri Desteği
For technical assistance, product inquiries, or to locate a service provider, please contact Eaton customer support directly. You can find contact information and additional resources on the official Eaton webalan: www.eaton.com.