1. Ürün Bittiview
The Forney 58402 is a heavy-duty Bakelite pin-type wall electrical receptacle designed for surface mounting. It features a 2-pole/3-wire grounding configuration, suitable for high-power applications. This receptacle is rated for 50 Amps at 125/250 Volts and conforms to NEMA 6-50 standards.
Temel Özellikler:
- Heavy duty Bakelite pin-type design for durability.
- Wall electrical receptacle for surface mounting.
- 2-pole/3-wire grounding for enhanced safety.
- 50 Amp with 125/250-Volt capacity.
- NEMA 6-50 electrical configuration.

Şekil 1: Ön view of the Forney 58402 Electrical Receptacle, showing the pin configuration and voltage/ampyaş reytingleri
2. Güvenlik Bilgileri
UYARI: Electrical work can be hazardous. Always disconnect power at the circuit breaker or fuse box before installing, servicing, or removing this receptacle. Failure to do so may result in serious injury or death. If you are unsure about any part of these instructions, consult a qualified electrician.
- Tüm yerel ve ulusal elektrik yönetmeliklerine uyulduğundan emin olun.
- Yalıtımlı eldivenler ve güvenlik gözlükleri gibi uygun kişisel koruyucu ekipman (KKD) kullanın.
- Ses seviyesini doğrulayıntagve amperage of your circuit match the receptacle's ratings (50A, 125/250V).
- Do not use this receptacle if it appears damaged.
- Çocukları elektrik tesisatlarından uzak tutun.
3. Kurulum ve Kurulum
This section provides general guidelines for installing the Forney 58402 wall receptacle. Specific wiring configurations may vary based on local codes and existing electrical systems.
Gerekli Aletler ve Malzemeler:
- Tornavidalar (Yıldız ve Düz Uçlu)
- Tel striptizci
- Cilttage test cihazı
- Mounting screws (appropriate for surface)
- Electrical box (if not already present)
Kurulum Adımları:
- Gücü Kesin: Locate the circuit breaker or fuse controlling the circuit where the receptacle will be installed and turn it OFF. Verify power is off using a voltage test cihazı.
- Montaj Yüzeyini Hazırlayın: Ensure the surface is clean, dry, and structurally sound. The receptacle is designed for surface mounting.
- Mount the Receptacle Base: Position the receptacle base on the desired surface. Use appropriate mounting screws to secure it firmly. The back of the receptacle features pre-drilled holes for this purpose.
- Kablo Bağlantıları: This receptacle is a 2-pole/3-wire grounding type (NEMA 6-50). It typically requires two hot wires (L1, L2) and one ground wire.
- Strip approximately 1/2 inch of insulation from each wire.
- Connect the L1 (Hot) wire to one of the brass-colored terminals.
- Connect the L2 (Hot) wire to the other brass-colored terminal.
- Connect the Ground wire (typically green or bare copper) to the green hexagonal grounding screw.
- Güvenli Kablolama: Tüm kablo bağlantılarının sıkı ve güvenli olduğundan emin olun. Terminallerin dışında hiçbir çıplak kablo görünmemelidir.
- Yeniden birleştirme: Carefully place the cover over the wired base and secure it with the provided screws.
- Gücü Geri Yükle: Once installation is complete and verified, turn the power back ON at the circuit breaker or fuse box.

Şekil 2: Geri view of the Forney 58402 Receptacle, showing the metal mounting plate and screw holes for surface installation.

Şekil 3: Alt view of the Forney 58402 Receptacle, illustrating the internal wiring access points and terminals.
4. Kullanım Talimatları
The Forney 58402 Electrical Receptacle is designed for straightforward operation.
- Uyumluluğu Doğrulayın: Ensure the plug of your electrical device is compatible with the NEMA 6-50 configuration of this receptacle.
- Fişi takın: Align the pins of your device's plug with the slots on the receptacle and firmly insert the plug.
- Fişi Çıkarın: To disconnect, grasp the plug firmly and pull it straight out from the receptacle. Do not pull by the cord.

Şekil 4: Yakın çekim view of the Forney 58402 Receptacle's pin configuration, showing the 50A 250V markings.
5. Bakım
Regular inspection and basic maintenance will help ensure the longevity and safe operation of your Forney 58402 receptacle.
- Periyodik muayene: Annually inspect the receptacle for any signs of damage, cracks, discoloration, or loose connections.
- Temizlik: With power disconnected, gently wipe the exterior of the receptacle with a dry, clean cloth to remove dust or debris. Do not use liquid cleaners.
- Bağlantıları Sıkın: If comfortable and with power disconnected, periodically check and tighten the terminal screws to ensure secure wire connections.
- Çevre Koruma: Reklamda kuruluysaamp or dusty environment, ensure the receptacle is adequately protected from moisture and excessive dust accumulation.
6. Sorun Giderme
If you experience issues with your Forney 58402 receptacle, consider the following common troubleshooting steps:
| Sorun | Olası Neden | Çözüm |
|---|---|---|
| No power from receptacle | Sigorta atmış veya devre kesici devre dışı kalmış | Check your electrical panel and reset the breaker or replace the fuse. |
| No power from receptacle | Gevşek kablo bağlantısı | With power disconnected, inspect and tighten all wire connections within the receptacle. |
| Fiş uymuyor | Incompatible plug type | Ensure your device's plug is a NEMA 6-50 type. Do not force incompatible plugs. |
| Receptacle feels hot | Aşırı yüklenme veya gevşek bağlantı | Immediately disconnect power. Reduce load or check wiring. Consult an electrician if problem persists. |
If troubleshooting steps do not resolve the issue, or if you are unsure, contact a qualified electrician.
7. Özellikler
| Bağlanmak | Değer |
|---|---|
| Marka | Forney |
| Örnek | 58402 |
| Tip | Pin-Type Wall Receptacle |
| Ampöfke | 50 Amps |
| Cilttage | 125/250 Volt |
| NEMA Yapılandırması | 6-50 |
| Direkler/Teller | 2-Pole, 3-Wire Grounding |
| Malzeme | Bakelite (Housing), Plastic (Body) |
| Renk | Siyah |
| Toplam Güç Çıkışı | 1 |
| Uyumlu Cihazlar | All (NEMA 6-50 compatible) |
8. Garanti ve Destek
Specific warranty details for the Forney 58402 Electrical Receptacle are not provided in this manual. For warranty information, technical support, or service inquiries, please refer to the product packaging or contact Forney customer service directly.
You may visit the official Forney webİletişim bilgileri ve ek kaynaklar için site: www.forneyind.com