1. Giriş
The Amprobe SM-CAL1 is a precision sound meter calibrator designed to ensure the accuracy and reliability of your sound level measurements. This device generates two fixed sound pressure levels, 94 decibels (dB) and 114 dB, at a frequency of 1,000 hertz (Hz), allowing for precise calibration of sound meters with microphones up to 1/2 inch in diameter. Regular calibration is crucial for maintaining measurement integrity and compliance with relevant standards.
This manual provides detailed instructions for the proper use, maintenance, and troubleshooting of your SM-CAL1 Sound Meter Calibrator.
2. Güvenlik Bilgileri
Please read and understand all safety instructions before operating the SM-CAL1. Failure to follow these guidelines may result in injury or damage to the device.
- Do not expose the calibrator to extreme temperatures, humidity, or direct sunlight.
- Cihazı düşürmekten veya güçlü darbelere maruz bırakmaktan kaçının.
- Do not attempt to open or modify the calibrator. Refer all servicing to qualified personnel.
- Çalışma sırasında pil bölmesinin güvenli bir şekilde kapalı olduğundan emin olun.
- Pilleri yerel düzenlemelere göre atın.
3. Paket İçeriği
Paketin içinde tüm öğelerin mevcut olduğundan emin olun:
- Amprobe SM-CAL1 Sound Meter Calibrator
- One (1) 9V battery (installed)
- Kullanım Talimatları (bu kılavuz)
4. Kurulum
4.1 Pil Kurulumu
The SM-CAL1 comes with a 9V battery pre-installed. If replacement is needed:
- Cihazın alt kısmında bulunan pil bölmesi kapağını bulun.
- Kapağı çıkarın.
- Yeni bir 9V pili, doğru kutuplara dikkat ederek bağlayın.
- Pil bölmesi kapağını güvenli bir şekilde yerine takın.
4.2 Preparing for Calibration
Before calibrating your sound meter, ensure its microphone is clean and free of debris. The SM-CAL1 is designed to fit microphones with a diameter of up to 1/2 inch.

Şekil 1: Amprobe SM-CAL1 Sound Meter Calibrator. The image shows the top face of the cylindrical calibrator, featuring the 'AMPROBE' logo, 'SM-CAL1' model number, a three-position slide switch labeled '94', 'OFF', and '114' (referring to dB levels), and text indicating 'db at 1kHz', 'IEC 942 1988 CLASS 2', and 'Sound Calibrator'. A red power indicator light is also visible.
5. Operasyon
5.1 Calibrating a Sound Meter
- Gently insert the microphone of your sound level meter into the opening on the top of the SM-CAL1 calibrator. Ensure a snug fit to minimize sound leakage.
- Select the desired calibration level using the slide switch on the calibrator:
- Slide to '94' for a 94 dB signal.
- Slide to '114' for a 114 dB signal.
- Observe the reading on your sound level meter. Adjust your sound meter's calibration settings until its display matches the selected output level of the SM-CAL1 (either 94 dB or 114 dB). Refer to your sound meter's user manual for specific calibration adjustment procedures.
- Once calibration is complete, slide the switch to 'OFF' to conserve battery life.
- Carefully remove the sound meter's microphone from the calibrator.
5.2 Düşük Pil Göstergesi
The SM-CAL1 is equipped with a low-battery indicator. When the battery voltage drops below a certain level, the indicator light will dim or not illuminate, signaling that the 9V battery needs to be replaced.
6. Bakım
6.1 Temizlik
To clean the exterior of the calibrator, use a soft, dry cloth. Do not use abrasive cleaners or solvents, as these may damage the casing veya dahili bileşenler.
6.2 Depolama
When not in use, store the SM-CAL1 in a cool, dry place, away from direct sunlight and extreme temperatures. If storing for extended periods, it is recommended to remove the 9V battery to prevent leakage.
6.3 Recalibration of the SM-CAL1
While the SM-CAL1 is designed for stable output, periodic verification of its accuracy by a certified calibration laboratory is recommended to ensure continued compliance with standards and optimal performance. The frequency of such recalibration depends on usage and regulatory requirements.
7. Sorun Giderme
| Sorun | Olası Neden | Çözüm |
|---|---|---|
| No sound output / Power indicator off | Pil bitmiş veya yanlış takılmış. | 9V pili, doğru kutuplara dikkat ederek değiştirin. |
| Inaccurate calibration readings on sound meter | Microphone not properly seated; Calibrator needs recalibration; Sound meter issue. | Ensure microphone is snugly fitted. Consider sending SM-CAL1 for professional recalibration. Check your sound meter's functionality. |
| Sound meter reading fluctuates | Ambient noise interference; Loose microphone connection. | Perform calibration in a quiet environment. Re-seat the microphone firmly. |
8. Özellikler
- Modeli: SM-CAL1
- Output Sound Pressure Levels: 94 dB ve 114 dB
- Çıkış Frekansı: 1,000 Hz (1 kHz)
- Mikrofon Uyumluluğu: Fits microphones up to 1/2 inch diameter
- Kesinlik: Meets IEC 942 1988 Class 2 standards
- Güç Kaynağı: One (1) 9V battery
- Düşük Pil Göstergesi: Evet
- Çalışma Sıcaklığı: 0°C ila 40°C (32°F ila 104°F)
- Depolama Sıcaklığı: -10°C ila 50°C (14°F ila 122°F)
- Dimensions (H x D): Yaklaşık 4.9 x 1.9 inç (125 x 48 mm)
- Ağırlık: Yaklaşık 0.6 lb (285 gr)
- Sertifikalar: CE compliant, ANSI, IEC standards
9. Garanti ve Destek
9.1 Garanti Bilgileri
Amprobe products are warranted against defects in material and workmanship for a specified period from the date of purchase. For detailed warranty terms and conditions, please refer to the warranty card included with your product or visit the official Ampelbise website. This warranty does not cover damage resulting from misuse, accident, neglect, alteration, contamination, or abnormal conditions of operation or handling.
9.2 Müşteri Desteği
If you encounter any issues or have questions regarding your Amprobe SM-CAL1 Sound Meter Calibrator, please contact Amprobe customer support. Before contacting support, ensure you have reviewed the troubleshooting section of this manual. You can find contact information on the official Ampelbise websitenizden veya yerel distribütörünüz aracılığıyla temin edebilirsiniz.