AGS BL512

AGS BL512 Yerli Çelik Fren/Yakıt/Şanzıman Hattı Kullanım Kılavuzu

Model: BL512 | Brand: AGS

1. Ürün Bittiview

The AGS BL512 is a domestic steel line designed for use in brake, fuel, and transmission systems. This durable component is engineered to provide reliable fluid transfer within automotive applications.

AGS BL512 Domestic Steel Brake/Fuel/Transmission Line with fittings

Figure 1: The AGS BL512 steel line, showing its robust construction and threaded fittings at each end, suitable for various automotive fluid transfer applications.

2. Özellikler

BağlanmakDetay
MarkaAGS
MalzemeÇelik
RenkGümüş grisi
Ürün Boyutları13"L x 13"W (as packaged)
Ürün Ağırlığı0.32 ons (yaklaşık 0.009 kg)
Nominal Duvar Kalınlığı1.3 ay (Note: This value may indicate a data anomaly and typically refers to a physical measurement unit.)
Dış Çap0.75 inç
Ürün Uzunluğu33.02 Santimetre (yaklaşık 13 inç)
UPC077146359156
Üretici Parça NumarasıBL-512

3. Kurulum ve Kurulum

Proper installation of the AGS BL512 line is crucial for safety and performance. This product is intended for professional installation or by individuals with significant automotive repair experience.

3.1 Güvenlik Önlemleri

3.2 Gerekli Araçlar ve Malzemeler

3.3 Kurulum Adımları (Genel)

  1. Hazırlık: Identify the old line to be replaced. Clean the surrounding area to prevent contamination.
  2. Kaldırma: Carefully disconnect the old line from its fittings. Be prepared for fluid leakage. Note the routing of the original line.
  3. Forming (if necessary): If the new line needs to be bent to match the original routing, use a tubing bender to create smooth, gradual bends. Avoid kinking the line.
  4. Kurulum: Route the new AGS BL512 line in the same path as the original. Secure it with appropriate clips or fasteners.
  5. Bağlantı: Connect the ends of the new line to the corresponding fittings. Hand-tighten first, then use a line wrench to tighten securely, but do not overtighten.
  6. Fluid System Specifics:
    • Fren Hatları: After installation, bleed the brake system thoroughly to remove all air. Check for leaks.
    • Yakıt Hatları: Check all connections for leaks before starting the engine.
    • Transmission Lines: Refill transmission fluid to the correct level and check for leaks.
  7. Son Muayene: Double-check all connections for tightness and ensure the line is not rubbing against any moving parts or sharp edges.

4. İşletme Hususları

Once installed, the AGS BL512 line operates as an integral part of your vehicle's fluid transfer system. Its function is passive, ensuring the safe and efficient flow of brake fluid, fuel, or transmission fluid as intended by the vehicle manufacturer.

No direct user operation is required for the line itself after proper installation and system bleeding/filling. The line is designed to withstand the pressures and temperatures typical of its intended automotive applications.

5. Bakım

The AGS BL512 steel line is a durable component designed for long service life. Regular inspection is recommended as part of routine vehicle maintenance to ensure continued safety and performance.

5.1 Denetim Takvimi

5.2 What to Look For

If any issues are detected, it is critical to address them promptly. A compromised brake, fuel, or transmission line can lead to serious safety hazards or vehicle damage. Replacement of the affected line is typically the recommended course of action.

6. Sorun Giderme

Troubleshooting issues related to the AGS BL512 line primarily involves identifying and addressing leaks or blockages. Given its passive role, most problems stem from improper installation or physical damage.

6.1 Yaygın Sorunlar ve Çözümler

SorunOlası NedenÇözüm
Fluid Leak at ConnectionLoose fitting, damaged flare, cross-threaded connectionTighten fitting (do not overtighten). If leak persists, inspect flare and fitting for damage. Replace line or fitting if damaged. Ensure correct threading.
Fluid Leak Along LineCorrosion, physical damage (kink, crack, abrasion)Replace the damaged section of the line or the entire line.
Restricted Fluid Flow (e.g., weak brakes, fuel starvation)Kinked line, internal blockage (rare for new lines)Inspect the line for kinks. If kinked, replace. If blockage is suspected, flush or replace the line.

For any persistent or severe issues, it is highly recommended to consult a qualified automotive technician.

7. Garanti ve Destek

For specific warranty information regarding the AGS BL512 Domestic Steel Brake/Fuel/Transmission Line, please refer to the documentation provided with your purchase or visit the official AGS webSite. Garanti şartları genellikle üretim hatalarını kapsar.

If you require technical assistance or have questions about the product, please contact AGS customer support through their official channels. Contact information can usually be found on the product packaging or the manufacturer's webalan.

AGS Official Webalan: www.agscompany.com (Not: Bu bir yer tutucudur URL, lütfen gerçek resmi bilgiyi doğrulayın website for AGS)

İlgili Belgeler - BL512

Önview AGS TP-DS-CO2RHT-BMS Dijital Kanal Montajlı CO2, Sıcaklık ve Nem Sensörü Teknik Özellikler Sayfası
Bu belge, CO2, sıcaklık ve nem için dijital kanal montajlı bir sensör olan AGS TP-DS-CO2RHT-BMS'nin teknik özelliklerini ayrıntılı olarak açıklamaktadır. Sensör, NDIR teknolojisi, BACnet MS/TP ve Modbus RTU uyumluluğu ve HVAC uygulamaları için otomatik kalibrasyon özelliklerine sahiptir.
Önview TSC2 ile VRS Ağları için Genel Bluetooth Cep Telefonu Yapılandırması
Bluetooth özellikli cep telefonlarının TSC2 cihazı kullanılarak VRS Ağlarıyla uyumlu olacak şekilde yapılandırılması adımlarını ayrıntılı olarak açıklayan kapsamlı bir kılavuz. İlk telefon kurulumunu, Bluetooth eşleştirmesini, ağ bağlantısı oluşturmayı ve internet bağlantısı testini kapsar.
Önview Merlin RG Serisi VRF Soğutucu Gaz Sensörü Kurulum ve Kullanım Kılavuzu
AGS Merlin RG Serisi VRF Soğutucu Gaz Sensörü için kapsamlı kurulum ve kullanım kılavuzu. Önemli güvenlik bilgileri, kurulum prosedürleri, kablolama, yapılandırma, çalıştırma, kalibrasyon ve teknik özellikler konularını kapsamaktadır.
Önview Merlin Gaz Dedektörü iS: American Gas Safety Kurulum, Kullanım ve Bakım Kılavuzu
Bu kılavuz, American Gas Safety Merlin Gaz Dedektörü iS için kurulum, çalıştırma, bakım, sorun giderme ve soğutucu gaz algılama özelliklerini kapsayan ayrıntılı talimatlar sağlar.
Önview AGS FAB-1 System User & Installation Manual
Detailed installation, operating, and maintenance instructions for the AGS FAB-1 Fire Alarm Bypass Panel, including setup, operation, and troubleshooting. Covers panel mounting, mains supply, connections, timeout facility, and LED status.
Önview AGS Mini Merlin CH4CO-35 Dual Gas Controller Installation and Operation Manual
Comprehensive installation, operation, and maintenance guide for the AGS Mini Merlin CH4CO-35 Dual Gas Controller, detailing safety, setup, wiring, operation, and maintenance procedures for detecting Methane (CH4) and Carbon Monoxide (CO).