Hi-Link HLK-LD2412

User Manual: HLK-LD2412 24G Human Presence and Motion Sensor Module

Model: HLK-LD2412 | Brand: Hi-Link

1. Giriş

The Hi-Link HLK-LD2412 is a high-sensitivity 24GHz human presence sensing module designed for detecting human targets within a defined space. Utilizing FMCW (Frequency Modulated Continuous Wave) radar technology, combined with advanced signal processing and a precise human body sensing algorithm, this module can identify both moving and stationary human presence. It also provides auxiliary information such as target distance.

Primarily intended for indoor applications, the HLK-LD2412 detects human movement or micromovement in an area and outputs real-time detection results. Its maximum sensing distance extends up to 9 meters, with a distance resolution of 0.75 meters. The module offers visual configuration tools, allowing users to easily adjust the induction distance range, sensitivity for different intervals, and unmanned delay time to suit various specific application requirements.

Supporting both GPIO and UART output, the HLK-LD2412 is designed for plug-and-play functionality, making it highly adaptable for integration into diverse intelligent scenarios and end products.

Hi-Link HLK-LD2412 module with pins labeled OUT, GND, +5V, 3V3, G, RX, TX
Figure 1: HLK-LD2412 24G Human Presence Detection Module. Features a sensing distance up to 9m and coverage up to ±75 degrees.
Comparison of old and new versions of the HLK-LD2412 module, highlighting optimized antenna layout and improved sensing performance in the new version.
Figure 2: Comparison of HLK-LD2412 Old and New Versions. Hardware dimensions and pinouts are consistent, product features are the same, but the new version optimizes antenna layout for improved sensing performance.

2. Özellikler

The HLK-LD2412 module offers robust performance for human presence detection. Key specifications are detailed below:

ParametreValue (HLK-LD2412)
Çalışma Frekans Bandı24.075-24.175GHz
ÖzellikLongest sensing distance up to 9m (adjustable)
İletim Gücü20dBm
Güç TüketimiDC 5V or DC 3.3V supply, average operating current >200mA
Algılama Mesafesi9m (adjustable)
Algılama Açısı±75°
Referencing MethodAPP/Serial port uplink
Çıktı TürüSerial protocol / High and low levels
Ürün Boyutları (U x G x Y)28.00mm x 11.00mm x 2mm (main board, excluding pins)
İletişim YöntemiBluetooth-Compatible (for APP configuration)
Table of specifications for various Hi-Link radar modules including HLK-LD2412
Figure 3: Detailed Specifications Table for Hi-Link Radar Modules (including HLK-LD2412).

3. Kurulum

3.1 Module Dimensions and Pinout

The HLK-LD2412 module is compact, designed for easy integration. Refer to the diagram below for precise dimensions and pin assignments.

HLK-LD2412 module dimensions with measurements in millimeters and pin labels
Figure 4: HLK-LD2412 Module Dimensions. Key dimensions are 28.00mm length, 11.00mm width, and pin spacing.

Pin Çıkışı Açıklaması:

  • DIŞARI: Output pin (GPIO)
  • TOPRAK: Zemin
  • +5 V: 5V Güç Kaynağı Girişi
  • 3V3: 3.3V Power Supply Input (can also be used as output if 5V is supplied)
  • G: Zemin
  • Alım: UART Receive Data
  • Teksas: UART Transmit Data

Ensure correct power supply (either 3.3V or 5V) and proper connection of UART (RX/TX) and GPIO (OUT) pins to your host system.

3.2 Kurulum Yöntemleri

The HLK-LD2412 module supports various installation methods, including ceiling-mounted and wall-mounted, to optimize detection coverage for different environments.

Diagram showing ceiling-mounted radar sensor detecting a person walking below, with height range 2.6m-3m
Figure 5: Ceiling-Mounted Installation. Recommended height range is 2.6m to 3m for optimal coverage.
Diagram showing wall-mounted radar sensor detecting a person sitting and a person walking, with height range 1.5m-2m and detection distance up to 9m
Figure 6: Wall-Mounted Installation. Recommended height range is 1.5m to 2m, with a detection distance up to 9m.

When installing, consider the desired detection area and potential obstructions. The module's good shell penetration allows it to be hidden inside non-metallic enclosures, enhancing product aesthetics without compromising performance.

4. Kullanım Talimatları

The HLK-LD2412 module is designed for flexible operation and configuration to meet diverse application needs.

4.1 Temel İşlemler

Once powered, the module begins sensing human presence. Detection results are output via the configured GPIO or UART interface. The module can detect both moving and static human bodies, including micromovements.

4.2 Yapılandırma ve Hata Ayıklama

The HLK-LD2412 supports multi-level intelligent parameter adjustment through visual debugging and configuration tools. These tools allow you to customize various operational parameters:

  • Induction Distance Range: Define the minimum and maximum detection distances.
  • Induction Sensitivity: Adjust sensitivity levels for different distance intervals to fine-tune detection accuracy and reduce false positives.
  • Unmanned Delay Time: Set the duration after which the module reports "no presence" if no human activity is detected.

Configuration is typically performed via an APP or serial port uplink. Refer to the specific software documentation provided by Hi-Link for detailed instructions on using the visual configuration tools and connecting via Bluetooth-Compatible or serial interface.

5. Uygulama Senaryoları

The HLK-LD2412 human body sensing module's ability to detect motion, micro-movement, standing, and sitting positions makes it suitable for a wide range of AIoT applications:

  • Human Body Induction Light Control: Automatic control of lighting based on human presence, ideal for public places, induction lights, and bulb lights.
  • Advertising Screen and Device Awakening: Automatically turn on advertising screens or other devices when a person approaches and enter sleep mode when no one is present, saving power and enhancing information delivery efficiency.
  • Life Safety Protection:
    • UV lamp work protection: Prevents UV lamps from being activated when people are nearby, avoiding personal injury.
    • Dangerous area monitoring: Automatic detection and alarm for unauthorized entry into high-risk spaces (e.g., coal mine blasting areas).
  • Smart Home Appliances: Automatically turn off TVs, air conditioners, and other electrical appliances when a room is unoccupied for an extended period, promoting energy saving and safety.
  • Intelligent Security: Detection and identification of intruders or individuals lingering within specified security zones.

6. Bakım

The HLK-LD2412 module is designed for low maintenance. To ensure optimal performance:

  • Keep the module clean and free from dust or debris, especially the antenna area.
  • Ensure proper ventilation if enclosed, to prevent overheating.
  • Avoid exposing the module to extreme temperatures or humidity outside its specified operating range.
  • Regularly check power connections for stability.

7. Sorun Giderme

If you encounter issues with your HLK-LD2412 module, consider the following troubleshooting steps:

  • No Detection / Intermittent Detection:
    • Gücü Kontrol Edin: Ensure the module is receiving stable 3.3V or 5V power.
    • Bağlantıları Doğrulayın: Confirm all pins (power, ground, UART, GPIO) are correctly connected and secure.
    • Review Atama: Ensure the module's detection area is not obstructed by large metallic objects or thick walls.
    • Hassasiyeti Ayarlayın: Use the configuration tools to increase the sensitivity, especially for detecting micromovements or at longer distances.
    • Check Detection Angle: Ensure the module is oriented correctly to cover the desired area (±75° detection angle).
  • False Positives (Detecting when no one is present):
    • Hassasiyeti Ayarlayın: Decrease the sensitivity using the configuration tools.
    • Çevresel Faktörler: While robust, extreme vibrations or rapid air movements might occasionally trigger detection. Ensure stable mounting.
    • Parazit yapmak: Ensure no other 24GHz devices are operating in close proximity that could cause interference.
  • Communication Issues (UART/APP):
    • Kablolamayı Kontrol Edin: Double-check RX/TX connections.
    • Baud Hızı: Ensure your host system's serial port baud rate matches the module's default or configured baud rate.
    • Uygulama Bağlantısı: For Bluetooth-Compatible APP, ensure Bluetooth is enabled on your device and the module is discoverable/paired correctly.

8. Kullanıcı İpuçları

  • Optimum Yerleştirme: For ceiling-mounted applications, a height of 2.6m-3m is generally recommended. For wall-mounted, 1.5m-2m is suitable. Experiment with placement to achieve the best coverage for your specific environment.
  • Fine-tuning Sensitivity: The ability to adjust sensitivity for different distance "doors" is a powerful feature. Use it to create zones where detection is more or less sensitive, preventing unwanted triggers or ensuring detection in critical areas.
  • Non-Metallic Enclosures: Avantajı yakalayıntage of the module's shell penetration capability by integrating it into non-metallic enclosures for a cleaner, more aesthetic installation.
  • Güç Kaynağı Kararlılığı: A stable and clean power supply (3.3V or 5V) is crucial for reliable operation. Use a regulated power source.

9. Garanti ve Destek

For technical support, warranty inquiries, or further assistance with your Hi-Link HLK-LD2412 module, please contact Shenzhen Hi-Link Electronic Co., Ltd. directly.

İletişim Bilgileri:

Hi-Link contact information including email and WhatsApp
Figure 7: Hi-Link Contact Information for Support.

Garanti işlemleri için lütfen satın alma fişinizi saklayın.

İlgili Belgeler - HLK-LD2412

Önview Hi-Link HLK-LD2410B: 24GHz Human Presence Sensing Module Manual
This manual provides comprehensive details on the Hi-Link HLK-LD2410B, a 24GHz millimeter wave radar sensor module for accurate human presence detection. Learn about its features, applications in smart lighting, security, and IoT, hardware specifications, and configuration via Bluetooth and PC tools.
Önview HLK-LD2410C İnsan Varlığı Hareket Modülü Kullanım Kılavuzu | Hi-Link
Hi-Link HLK-LD2410C 24GHz insan varlığı hareket algılama modülü için ayrıntılı kullanım kılavuzu. Özellikleri, uygulamaları, donanımı, yapılandırmayı, Bluetooth, OTA yükseltmelerini, performansı ve radome tasarımını kapsar.
Önview HLK-LD2410B İnsan Varlığı Algılama Modülü Kullanıcı Kılavuzu
Yüksek hassasiyetli 24 GHz insan varlığı algılama modülü Hi-Link HLK-LD2410B için kapsamlı kullanıcı kılavuzu. Özellikleri, uygulamaları, donanımı, yapılandırmayı, Bluetooth'u, performansı ve radome tasarım yönergelerini ayrıntılı olarak açıklar.
Önview HLK-LD2410 Radar Module User Manual
User manual for the Hi-Link HLK-LD2410 24GHz human presence status radar module. Details features, application scenarios, hardware description, usage, configuration, performance, installation guidelines, and technical support.
Önview HLK-LD6001A-60G İnsan Vücudu Yörünge Radar Modülü Kullanım Kılavuzu - Hi-Link
Hi-Link HLK-LD6001A-60G milimetre dalga radar modülü için kapsamlı kullanıcı kılavuzu. İç mekanda insan varlığı ve yörünge tespiti için ayrıntılı özellikler, elektriksel özellikler, kurulum, parametre yapılandırması ve iletişim protokolleri.
Önview HLK-LD2410 Human Presence Sensing Module User Manual
User manual for the Hi-Link HLK-LD2410 24GHz human presence sensing module, detailing its features, applications, hardware description, configuration, performance parameters, and radome design guidelines.