1. Giriş
Thank you for choosing the S4A RFID Metal Access Control Keypad (Model SA-0103). This device provides a secure and convenient solution for managing access to your premises. Featuring a robust metal construction, support for RFID keytags/cards, and PIN code entry, it is designed for reliable operation. When installed outdoors, the included rainproof cover offers additional protection against environmental elements. This manual will guide you through the installation, operation, and maintenance of your access control system.
2. Özellikler
| Özellik | Tanım |
|---|---|
| Marka Adı | S4A |
| Model Numarası | SA-0103 |
| Boyut | 120mm x 56mm x 18mm |
| İş Hacmitage | Doğru Akım 12V |
| Statik akım | ≤30mA |
| Okuma aralığı | 3cm ~ 8cm |
| Kapasite | 2000 kullanıcı |
| Ortam Sıcaklığı | -25°C ~ 60°C |
| Ortam Nemi | %10 ~ %90 |
| Elektrikli Kilit Çıkışı | ≤3A |
| Alarm Çıkışı | ≤20A |
| Output Short Circuit Protection Time | ≤100μS |
| Açık Zaman | 0 ~ 99 seconds (adjustable) |
Rainproof Housing Dimensions:
- Outer size: 150mm x 104mm x 90mm
- Inner size: 135mm x 89mm x 84mm



3. Paket İçeriği
Your S4A RFID Metal Access Control Keypad package typically includes the following items:
- 1x S4A RFID Metal Access Control Keypad (Model SA-0103)
- 7x RFID Keytags or Thin Cards (quantity and type may vary based on purchase option)
- 1x Rainproof Housing (for outdoor installation)
- Montaj vidaları ve dübeller
- Kullanım Kılavuzu (bu belge)


4. Ürün Bittiview
The SA-0103 access control keypad is designed for durability and ease of use. Its metal casing provides enhanced security and longevity. The keypad features backlit buttons for visibility in low-light conditions, and LED indicators to show the system's status. A built-in doorbell function adds convenience.

5. Kurulum ve Kurulum
Proper installation is crucial for the optimal performance and security of your access control system. It is recommended that installation be performed by a qualified technician.
5.1. Tuş Takımının Montajı
- Choose a suitable mounting location near the door, ensuring it is easily accessible and within reach of necessary wiring.
- If installing outdoors, first mount the rainproof housing. The keypad is surface waterproof, but the housing provides additional protection against direct rain and harsh weather.
- Use the keypad dimensions (120mm x 56mm) and the rainproof housing dimensions (150mm x 104mm) as a guide for placement.
- Mark the drilling points on the wall using the keypad's backplate as a template.
- Gerekirse delikler açın ve dübel takın.
- Secure the keypad to the wall using the provided screws.


5.2. Kablolama Şeması
The keypad requires a DC 12V power supply and connects to an electric lock, an exit button, and optionally a doorbell. Follow the wiring diagrams carefully.


Kablo Bağlantıları:
- +12V ve GND: Connect to a stable DC 12V power supply.
- KİLİT: Connect to the electric lock. Ensure compatibility with your lock type (Normally Open - NO or Normally Closed - NC).
- REX/BL: Connect to the exit button.
- BELL1 and BELL2: Connect to an external doorbell.
- AUX_IN and AUX_OUT: Auxiliary input/output for advanced functions (refer to specific programming instructions for details).
- COM, HAYIR, NC: These terminals are for connecting various types of electric locks. COM is common, NO (Normally Open) means the circuit is open when the lock is de-energized, and NC (Normally Closed) means the circuit is closed when the lock is de-energized. Choose the appropriate connection based on your lock's requirements.
Warning: Incorrect wiring can damage the device or connected components. Always ensure power is disconnected before performing any wiring.
6. Kullanım Talimatları
The SA-0103 keypad supports multiple access methods and programming options.
6.1. Temel İşlem
- Access with RFID: Present a programmed RFID keytag or card to the keypad. The door will unlock for the set open time.
- Access with PIN: Enter your programmed PIN code followed by the '#' key. The door will unlock for the set open time.
- kapı zili işlevi: Press the bell icon button on the keypad to activate the connected doorbell.
6.2. Programlama Modu
To enter programming mode, you typically need to enter a master code. The default master code is often 123456 or 999999, but please refer to the specific programming guide that came with your unit for the exact default code and programming steps.
General Programming Steps (may vary slightly):
- Programlama Moduna Girin: Enter the Master Code, then press
#. The LED indicator will change (e.g., from red to green or flash). - Add User (RFID Card/Keytag):
- While in programming mode, enter the command for adding a user (e.g.,
1). - Present the new RFID card/keytag tuş takımına.
- The keypad will beep to confirm successful addition.
- While in programming mode, enter the command for adding a user (e.g.,
- Add User (PIN Code):
- While in programming mode, enter the command for adding a user (e.g.,
2). - Enter the desired PIN code (4-6 digits), then press
#. - Re-enter the PIN code, then press
#Tekrar onaylamak için. - The keypad will beep to confirm successful addition.
- While in programming mode, enter the command for adding a user (e.g.,
- Kullanıcıyı sil:
- While in programming mode, enter the command for deleting a user (e.g.,
3). - To delete by RFID: Present the RFID card/keytag silinecek.
- To delete by PIN: Enter the PIN code to be deleted, then press
#. - The keypad will beep to confirm deletion.
- While in programming mode, enter the command for deleting a user (e.g.,
- Ana Kodu Değiştir:
- While in programming mode, enter the command for changing the master code (e.g.,
8). - Enter the new Master Code, then press
#. - Re-enter the new Master Code, then press
#Tekrar onaylamak için.
- While in programming mode, enter the command for changing the master code (e.g.,
- Adjust Open Time:
- While in programming mode, enter the command for adjusting open time (e.g.,
9). - Enter the desired open time in seconds (0-99), then press
#.
- While in programming mode, enter the command for adjusting open time (e.g.,
- Programlama Modundan Çık: Basmak
*or wait for a timeout.
Note: Always refer to the specific programming instructions provided with your device for exact commands and sequences.
7. Bakım
- Temizlik: Tuş takımının yüzeyini yumuşak bir bezle silin.amp Bez kullanın. Aşındırıcı temizleyiciler veya çözücüler kullanmaktan kaçının, çünkü bunlar yüzeye ve elektronik bileşenlere zarar verebilir.
- Dış Mekan Koruması: If installed outdoors, regularly check that the rainproof cover is securely in place and free from cracks or damage. Ensure no water can accumulate around the keypad.
- Kablolama Denetimi: Tüm kablo bağlantılarını periyodik olarak kontrol ederek sağlam olduklarından ve korozyon veya hasardan arınmış olduklarından emin olun.
- İşlevsellik Kontrolü: Test the keypad's functionality (RFID, PIN, doorbell, exit button) regularly to ensure it is operating correctly.
8. Sorun Giderme
- Tuş takımı yanıt vermiyor: Check the power supply connection. Ensure the DC 12V power adapter is functioning and properly connected to the keypad's +12V and GND terminals.
- Geçerli giriş yapıldıktan sonra kapı açılmıyor:
- Verify that the user's RFID card/PIN is correctly programmed.
- Check the wiring to the electric lock. Ensure it matches the lock type (NO/NC) and is securely connected.
- Confirm the 'Open Time' setting is not set to 0 or an extremely short duration.
- RFID card/keytag is not being read: Ensure the card is presented within the 3-8cm reading range. Check if the card is damaged or if it's a compatible type.
- Doorbell button does not work: Inspect the wiring to the external doorbell (BELL1 and BELL2 terminals). Ensure the doorbell itself is functional.
- Keypad beeps continuously or shows an error: This may indicate a tamper alarm or a system error. Refer to the specific programming guide for error codes or reset procedures. Disconnecting and reconnecting power can sometimes resolve temporary glitches.
- Keypad is not backlit: Check power supply and wiring. If the issue persists, there might be an internal fault.
9. Kullanıcı İpuçları
- Secure Your Master Code: Always change the default master code immediately after installation and keep the new code in a secure, memorable location.
- Dış Mekan Koruması: For outdoor installations, even though the keypad is surface waterproof, always utilize the provided rainproof cover. This significantly extends the lifespan of the device by protecting it from direct exposure to rain and harsh weather conditions.
- Düzenli Olarak Test Edin: Periodically test all access methods (RFID, PIN) and the exit button to ensure the system is functioning as expected.
- Yedek Erişim: Consider having a backup method of entry in case of power failure or system malfunction.
10. Garanti ve Destek
This S4A RFID Metal Access Control Keypad comes with a 2-year guarantee, ensuring quality and reliability. For technical assistance, troubleshooting beyond this manual, or to inquire about warranty claims, please contact your original vendor or the S4A customer support channel.