AOPUTTRIVER AP-9000F

AOPUTTRIVER AP-9000F Hot Wire Anemometer User Manual

Model: AP-9000F

1. Giriş ve Üzeriview

The AOPUTTRIVER AP-9000F is a professional handheld hot wire anemometer designed for precise measurement of air velocity, airflow volume (CFM/CMM), and air temperature. This device is equipped with a retractable sensor probe, making it suitable for various applications, including HVAC system diagnostics, environmental monitoring, and industrial air flow analysis. This manual provides essential information for the safe and effective operation of your AP-9000F anemometer.

2. Kutuda Neler Var?

Paketi açtığınızda lütfen aşağıda listelenen tüm öğelerin mevcut ve iyi durumda olduğundan emin olun:

  • AP-9000F Hot Wire Anemometer Unit
  • Kullanıcı Kılavuzu
  • Tip-C Veri Kablosu
Contents of the AP-9000F package including the anemometer, manual, and charging cable.
Figure 2.1: Contents of the AP-9000F package. Includes the main unit, user manual, and Type-C data cable.

3. Ürün Özellikleri

The AP-9000F anemometer offers a range of features designed for precision and convenience:

  • 3'ü 1 arada Ölçüm: Accurately measures wind speed (m/s, km/h, ft/min, knots, mph), airflow (CFM/CMM), and wind temperature (°C/°F).
  • Retractable Sensor Probe: Features a flexible, extendable probe tip for convenient measurements in confined or hard-to-reach spaces, such as air conditioning vents. Probe dimensions: 298.5 × 40.84 × 23.7 mm.
  • LCD Ekran: A clear, backlit LCD presents wind speed (Max, Min, Real-time), airflow, temperature, and humidity data. Includes anti-interference buttons and a low battery indicator.
  • C Tipi Arayüz: Equipped with a Type-C charging port and powered by a 1000mAh lithium-ion battery. Supports an optional auto-shutdown function.
  • Geniş Uygulama: Suitable for environmental measurements, air transportation, and air conditioning monitoring systems.
Diagram highlighting key features of the handheld anemometer including 5 units, MAX/MIN/AVG, LCD Backlit, C/F optional, automatic power off, airflow/temperature, and 360 degree bending probe.
Figure 3.1: Key features of the AP-9000F handheld anemometer.
Image showing the retractable probe being used for small space measurement in an air conditioning unit, demonstrating its 360 degree revolve capability.
Figure 3.2: The retractable sensor probe allows for 360° rotation, facilitating measurements in tight or small spaces.

4. Kurulum

4.1 Pilin Şarj Edilmesi

The AP-9000F is powered by a built-in 1000mAh lithium-ion battery. Before first use, or when the low battery indicator appears on the LCD, charge the device using the provided Type-C data cable.

  • Connect the Type-C cable to the charging port on the anemometer and the other end to a standard USB power adapter (not included).
  • A full charge typically takes 2 to 3 hours.
  • Not: The device cannot be turned on or operated while it is charging.

4.2 Extending the Sensor Probe

The hot wire sensor is located at the tip of the retractable probe. Carefully extend the probe to the desired length for measurement. The probe can be rotated 360 degrees for optimal positioning.

  • Gently pull the probe from the main unit to extend it.
  • Adjust the angle of the probe tip as needed.
  • After use, retract the probe back into the unit for protection.

5. Kullanım Talimatları

5.1 Cihaz Düzeni ve Düğmeler

Labeled diagram of the AOPUTTRIVER AP-9000F Hot Wire Anemometer, showing the sensor, sensor protective cover, connecting cable, LCD screen, power button, wind speed/volume unit switch button, Max/Min/real-time value switch button, C/F switch button, data hold button, and set air volume area button.
Şekil 5.1: Üzeriview of the AP-9000F anemometer and its controls.
  • Power Button (Red Circle): Cihazı AÇMAK veya KAPATMAK için basın.
  • MOD Düğmesi: Switches between different measurement modes (e.g., wind speed, airflow).
  • BİRİM Düğmesi: Changes the unit of measurement for wind speed (m/s, km/h, ft/min, knots, mph) or airflow (CFM, CMM).
  • Ayarlama düğmesi: Used to set the air volume area for accurate CFM/CMM calculations.
  • MAKS/DAK Düğmesi: Toggles between maximum, minimum, and real-time values on the display.
  • TUTMA Düğmesi: Ekrandaki mevcut okumayı dondurur. Serbest bırakmak için tekrar basın.
  • °C/°F Düğmesi: Switches the temperature unit between Celsius and Fahrenheit.

5.2 Temel Ölçüm Prosedürü

  1. Güç Açık: Basın Güç Düğmesi to turn on the anemometer. The LCD will illuminate.
  2. Extend Probe: Carefully extend the sensor probe and position it in the airflow you wish to measure. Ensure the sensor tip is fully exposed to the air stream.
  3. Mod seç: Basın MOD Düğmesi to select between wind speed, airflow, or temperature measurement.
  4. Birim Seçin: Basın BİRİM Düğmesi to choose your preferred unit (e.g., m/s, CFM, °C).
  5. Set Area (for Airflow): If measuring airflow (CFM/CMM), press the SET Düğmesi to input the cross-sectional area of the duct or vent. Refer to the specifications for area input range.
  6. Ölçümü Oku: The current readings will be displayed on the LCD.
  7. Veri tutma: Basın HOLD Düğmesi to freeze the current reading. Press again to resume live measurement.
  8. Max/Min/Avg: Kullanın MAX/MIN Düğmesi ile view the maximum, minimum, or average readings recorded during the measurement session.
The AP-9000F LCD display showing wind speed, airflow, temperature, and humidity data with backlight activated.
Figure 5.2: The clear LCD display with backlight for easy reading in various lighting conditions.
Screenshots of the AP-9000F display showing Original screen, MAX, MIN, and AVG measurement modes for airflow.
Figure 5.3: The three measurement modes (Original, MAX, MIN, AVG) available on the AP-9000F.
Close-up of the AP-9000F display showing the HOLD button being pressed to retain a reading, useful in dark environments.
Figure 5.4: Using the HOLD button to freeze the display for convenient reading.

6. Bakım

6.1 Cihazın Temizlenmesi

  • Ana üniteyi yumuşak, kuru bir bezle silin. Aşındırıcı temizleyiciler veya çözücüler kullanmayın.
  • For the sensor probe, gently clean any dust or debris. Avoid touching the delicate hot wire sensor directly.

6.2 Pil Bakımı ve Saklama

  • Pil sağlığını korumak için, cihazı sık kullanmasanız bile pili düzenli olarak şarj edin.
  • Store the anemometer in a cool, dry place, away from direct sunlight and extreme temperatures.
  • Ensure the sensor probe is fully retracted and protected during storage.

7. Sorun Giderme

If you encounter issues with your AP-9000F, please refer to the following common problems and solutions:

SorunOlası NedenÇözüm
Cihaz açılmıyorLow battery; Device is chargingCharge the battery fully; Disconnect from charger before powering on.
Yanlış okumalarSensor obstructed or dirty; Incorrect unit/mode selected; Probe not properly positionedClean the sensor gently; Verify selected mode and unit; Ensure sensor is fully in the airflow.
Ekran boş veya donmuşBattery low; HOLD function active; Device malfunctionRecharge battery; Press HOLD button to release; If problem persists, contact support.
Cannot change units/modesButtons unresponsive; Device in a locked stateEnsure buttons are pressed firmly; Power cycle the device (turn off and on).

8. Özellikler

Detailed technical specifications for the AOPUTTRIVER AP-9000F Hot Wire Anemometer:

ParametreDeğer
Rüzgar Hızı Ölçüm Aralığı0.1 – 30 m/sn
Air Temperature Measurement Range0 - 45 ° C (32 - 113 ° F)
Airflow Measurement Range (CFM)0 – 999,900 ft³/min
Airflow Measurement Range (CMM)0 – 999,900 m³/dk
Prob Boyutları298.5 × 40.84 × 23.7 mm
Pil Türü1000 mAh Lityum İyon
Şarj PortuTip-C
GörüntülemekArkadan Aydınlatmalı LCD
Ağırlık0.12 Pound (yaklaşık 54g)
Table detailing Airflow Measurement units, range, resolution, and area for CMM and CFM.
Figure 8.1: Detailed specifications for Airflow Measurement (CMM/CFM).

9. Garanti ve Destek

9.1 Garanti Bilgileri

AOPUTTRIVER products are manufactured to high-quality standards. This product is covered by a limited warranty against defects in materials and workmanship. Please refer to the warranty card included with your product for specific terms and conditions, or visit the official AOPUTTRIVER webDaha detaylı bilgi için sitemizi ziyaret edin.

9.2 Müşteri Desteği

For technical assistance, troubleshooting, or inquiries regarding your AP-9000F Hot Wire Anemometer, please contact AOPUTTRIVER customer support. Contact information can typically be found on the product packaging, the official AOPUTTRIVER website veya satın alma platformunuz aracılığıyla.

When contacting support, please have your product model (AP-9000F) and a detailed description of the issue ready.

© 2023 AOPUTTRIVER. Tüm hakları saklıdır.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.