1. Ürün Bittiview
The SINOTIMER SVP719 is a 3-in-1 adjustable voltage surge protector relay designed for single-phase 120VAC systems. It integrates over-voltage koruma, düşük hacimtage protection, current limiting, and energy metering functions. This device features three digital LED displays for real-time monitoring of voltage, current, and energy consumption (kWh). It is equipped with automatic recovery capabilities, ensuring electrical equipment protection by cutting off power during abnormal conditions and automatically restoring it when parameters return to normal. The unit is designed for easy installation on a universal DIN 35mm standard guide rail.

Ön view of the SINOTIMER SVP719 Adjustable Voltage Surge Protector.

Detailed diagram of the SVP719 showing displays and controls.
2. Güvenlik Bilgileri
Kurulum ve çalıştırmadan önce lütfen tüm güvenlik talimatlarını dikkatlice okuyun. Bu talimatlara uyulmaması elektrik çarpmasına, yangına veya ciddi yaralanmalara neden olabilir.
- Kurulum yalnızca kalifiye personel tarafından yapılmalıdır.
- Ensure the main power supply is disconnected before any wiring or maintenance.
- Doğru hacmi doğrulayıntage and current ratings for your application.
- Cihazı ıslak veya nemli ortamlarda çalıştırmayın.amp koşullar.
- Do not attempt to repair or modify the device. Contact qualified service personnel.
3. Kurulum ve Kurulum
The SVP719 is designed for easy installation on a standard 35mm DIN rail. Follow the wiring diagram below for proper connection.
3.1 Montaj
Mount the device securely onto a 35mm DIN rail within an electrical enclosure.
3.2 Kablo Bağlantıları
Connect the device according to the provided wiring diagram. Ensure all connections are tight and secure to prevent loose contacts and potential hazards.
- N Input: Connect the neutral wire from the power source.
- L Input: Connect the live wire from the power source.
- N Output: Connect the neutral wire to the load.
- L Output: Connect the live wire to the load.

Wiring Diagram for SVP719.
4. Kullanım Talimatları
The SVP719 features three LED displays and four control buttons for monitoring and configuration.
4.1 LED Ekranlar
- Cilttage Ekran (V): Gerçek zamanlı volümü gösterirtage devre.
- Mevcut Ekran (A): Shows the real-time current flowing through the circuit.
- Kilowatt-hour Display (kWh): Shows the accumulated energy consumption.
4.2 Kontrol Düğmesi
- Ayarlama düğmesi: Used to enter the parameter setting mode and cycle through different adjustable parameters.
- Yukarı Ok Düğmesi: Used to increase the value of a selected parameter.
- Aşağı Ok Düğmesi: Used to decrease the value of a selected parameter.
- AÇIK/KAPALI Düğmesi: Used to manually turn the power supply to the load ON or OFF.
4.3 Manual ON/OFF Operation
Basın AÇIK/KAPALI button to manually switch the power to the connected load. The display will show 'OFF' when power is disconnected and 'ON' when connected.
4.4 Kilowatt-hour (kWh) Reset
To reset the accumulated Kilowatt-hour (kWh) reading, press the Aşağı Ok Ve AYARLAMAK buttons simultaneously. The kWh display will reset to 000.0.
This video demonstrates the key features and operation of the SINOTIMER SVP719, including parameter adjustment, over-voltage koruma, düşük hacimtage protection, and manual ON/OFF control.
5. Parametre Ayarları
The SVP719 allows for adjustment of various protection parameters. All parameters are adjustable within specified ranges.
5.1 Entering Setting Mode
Basılı tutun AYARLAMAK button for approximately 3 seconds to enter the parameter setting mode. The first adjustable parameter will appear on the display.
5.2 Cycling Through Parameters
Once in setting mode, short press the AYARLAMAK button to cycle through the parameters sequentially. Each press will display the next parameter.
5.3 Adjusting Parameter Values
When a desired parameter is displayed, use the Yukarı Ok Ve Aşağı Ok buttons to adjust its value. The display will flash while adjusting.
5.4 Saving Settings and Exiting
After adjusting a parameter, wait for approximately 5 seconds without pressing any button. The device will automatically save the new setting and exit the setting mode, returning to normal operation.
5.5 Ayarlanabilir Parametreler
- U> (Over-voltage Protection Value): Sets the upper voltage limit. If the voltage exceeds this value, the protector will trip.
- U< (Under-voltage Protection Value): Sets the lower voltage limit. If the voltage drops below this value, the protector will trip.
- I> (Over-current Protection Value): Sets the maximum current limit. If the current exceeds this value, the protector will trip.
- t-on (Fault Recovery Delay Time): Sets the delay before the device automatically reconnects after a fault (over/under voltage, over-current) has cleared.
- t-off (Reset/Start Delay): Sets the delay for initial power-on or manual reset.
- CAL-A (Current Calibration): Allows for fine-tuning of the current measurement.
- CAL-V (Voltage Kalibrasyon): Allows for fine-tuning of the voltage ölçümü.
- CLP (Clear kWh): Resets the energy consumption counter.
6. Koruma Özellikleri
The SVP719 provides robust protection for your electrical equipment.
6.1 Aşırı Sestage Koruma
When the circuit voltage ayarlanan aşırı hacmi aşıyortage protection value (U>), the protector will instantaneously cut off the power supply to prevent damage to connected devices. The display will indicate an over-voltage durumu.
6.2 Düşük Voltage Koruma
If the circuit voltage drops below the set under-voltage protection value (U<), the protector will immediately disconnect the power. The display will indicate an under-voltage durumu.
6.3 Aşırı Akım Koruması
Should the current drawn by the load exceed the set over-current protection value (I>), the device will trip and cut off power to protect the circuit and load.
6.4 Automatic Recovery
After a fault condition (over-voltage, cilt altıtage, or over-current) has been detected and the power supply is cut off, the SVP719 will continuously monitor the circuit. Once the voltage and current return to normal operating ranges for the duration of the set recovery delay time (t-on), the protector will automatically restore power to the load.
7. Bakım
To ensure optimal performance and longevity of your SVP719, follow these simple maintenance guidelines:
- Regularly inspect the device for any signs of physical damage or loose connections.
- Cihazınızı temiz ve toz ve kalıntılardan uzak tutun. Temizlik için kuru ve yumuşak bir bez kullanın.
- Aşındırıcı temizleyiciler veya çözücüler kullanmayınız.
- Cihazın aşırı ısınmasını önlemek için çevresinde yeterli havalandırma olduğundan emin olun.
8. Sorun Giderme
If you encounter issues with your SVP719, refer to the following common problems and solutions:
| Sorun | Olası Neden | Çözüm |
|---|---|---|
| Cihaz açılmıyor | No input power; incorrect wiring | Check main power supply; verify wiring connections as per diagram. |
| Power cuts off frequently | Cilttage/current outside set limits; sensitive settings | Check actual voltage/current; adjust protection parameters (U>, U<, I>) to appropriate levels for your load. |
| Device does not recover automatically | Fault condition still present; recovery delay too long | Hacmi sağlayıntage/current has returned to normal; check and adjust 't-on' recovery delay setting. |
| kWh reading is inaccurate | Kalibrasyon gerekli | Perform current and voltage calibration (CAL-A, CAL-V) if you have a reference meter. |
9. Özellikler
Technical specifications for the SINOTIMER SVP719-1-63A model:

Technical specifications printed on the device casing.
| Özellik | Şartname |
|---|---|
| Marka | SİNOTİMER |
| Model Numarası | SVP719-1-63A |
| Cilttage | 120 Volt AC |
| Maksimum Akım | 63 Amps |
| Mağaza Sayısı | 1 |
| Özel Özellik | Surge Protection, Over-voltage Koruma, Düşük hacimlitage Protection, Current Limiting, Energy Metering |
| Güç Fişi Tipi | A Tipi - 2 pimli (Kuzey Amerika) |
| Kurulum | DIN 35mm Standard Guide Rail |
| UPC | 607606586190 |
10. Garanti ve Destek
The SINOTIMER SVP719-1-63A comes with a 1 Yıl Üretici Garantisi.
For technical support, warranty claims, or further assistance, please contact SINOTIMER customer service through their official channels or the retailer from whom the product was purchased. Please have your product model number (SVP719-1-63A) and purchase details ready when contacting support.