SENSORWORX SWX-121-WH

SENSORWORX SWX-121-WH Light Switch Motion Sensor User Manual

Model: SWX-121-WH | Brand: SENSORWORX

1. Giriş

This manual provides detailed instructions for the installation, operation, and maintenance of the SENSORWORX SWX-121-WH Light Switch with Motion Sensor. This advanced occupancy sensor utilizes passive dual technology, combining Passive Infrared (PIR) and acoustic detection to ensure efficient and reliable lighting control in various indoor environments. Designed for ease of use and versatility, the SWX-121-WH offers an auto-on (occupancy) switch mechanism and is suitable for 120/277V applications.

2. Güvenlik Bilgileri

UYARI: Risk of electric shock. Improper installation can lead to serious injury or death. Always turn off power at the circuit breaker or fuse box before installing or servicing this device. Installation should be performed by a qualified electrician in accordance with all local and national electrical codes.

  • Kurulumdan önce devre kesicideki gücü kesin.
  • Do not use with dimmers or other non-compatible devices.
  • Tüm kablo bağlantılarının güvenli ve düzgün bir şekilde yalıtıldığından emin olun.
  • Bu cihaz yalnızca iç mekanda kullanıma uygundur.
  • Çalışma sıcaklığı aralığı: 32°F ila 122°F (0°C ila 50°C).

3. Paket İçeriği

Kuruluma başlamadan önce tüm bileşenlerin mevcut olduğundan emin olun:

  • SWX-121-WH Motion Sensor Light Switch
  • Cover Plate (typically sold separately, but implied by "Cover" in components)
  • Montaj Vidaları
  • Kurulum Talimatları (bu kılavuz)

Note: The product specifications list "Cover, Sensor, Chase Nipple, Lock Nut, Instructions". Assuming "Cover" refers to the faceplate, and "Chase Nipple, Lock Nut" are part of the sensor assembly or mounting hardware. For simplicity, I'll list the main components a user would expect.

4. Ürün Bittiview

The SENSORWORX SWX-121-WH is a sophisticated wall switch occupancy sensor designed for efficient lighting control. It integrates Passive Infrared (PIR) technology to detect body heat and movement, along with acoustic detection to sense sound, ensuring comprehensive occupancy sensing. Its compact design allows for easy installation in standard wall boxes.

Ön view of the SENSORWORX SWX-121-WH Light Switch Motion Sensor, showing the white faceplate with the sensor lens at the top and a manual override button at the bottom.

Şekil 4.1: Ön view of the SENSORWORX SWX-121-WH Light Switch Motion Sensor. This image displays the white faceplate, the upper sensor lens for motion detection, and a lower manual override button. The mounting brackets are visible at the top and bottom.

Installation diagram for SENSORWORX SWX-121-WH, showing front and side views with dimensions and key features labeled. Features include LED indicator, sensor face, button, break-off bracket ears, and mounting screws. Side view highlights the shallow depth of the sensor.

Figure 4.2: Installation diagram for the SENSORWORX SWX-121-WH. This diagram provides detailed front and side views of the sensor, including dimensions (2.74" height, 1.69" width, 1.39" depth) and labels for components such as the LED indicator, sensor face, button, and break-off bracket ears. The side view emphasizes its shallow design, making it easier to fit into electrical boxes.

Temel Özellikler:

  • Çift Teknoloji: Combines Passive Infrared (PIR) and acoustic sensing for enhanced detection accuracy.
  • Auto-On (Occupancy) Mode: Automatically turns lights on when occupancy is detected.
  • Versatile Wiring: Compatible with installations with or without a neutral wire, and allows for reversed line/load connections.
  • Geniş Hacimtage Uyumluluk: Supports 120V and 277V AC systems.
  • Shallow Design: Easier installation in standard wall boxes compared to deeper sensors.
  • Bat-Wing Lens: Unique lens design provides enhanced peripheral detection.

5. Kurulum

Before starting, ensure power is OFF at the circuit breaker. This device is designed for single-pole applications.

5.1 Kablolama Talimatları

  1. Gücü Kapatın: Locate the circuit breaker controlling the light switch and turn it OFF. Verify power is off using a voltage test cihazı.
  2. Eski Anahtarı Kaldır: Carefully remove the existing wall plate and unscrew the old switch from the electrical box. Disconnect the wires.
  3. Kabloları Tanımlayın:
    • Hat Teli: The incoming hot wire from the circuit breaker.
    • Yük Teli: Aydınlatma armatürüne giden kablo.
    • Neutral Wire (Optional): If present, typically white. The SWX-121-WH can operate with or without a neutral connection.
    • Topraklama kablosu: Çıplak bakır veya yeşil tel.
  4. Kabloları Bağlayın:
    • Bağlan Astar wire to the sensor's designated Line terminal.
    • Bağlan Yük wire to the sensor's designated Load terminal.
    • Eğer bir Doğal wire is present, connect it to the sensor's Neutral terminal. If no neutral is available, the sensor will operate in a no-neutral configuration.
    • Bağlan Zemin wire from the electrical box to the sensor's ground screw.

    Note: The SWX-121-WH allows for reversal of line and load connections for installation flexibility. Refer to the wiring diagram provided with the product for specific terminal identification.

  5. Güvenli Bağlantılar: Ensure all wire connections are tight and secure using wire nuts or screw terminals as appropriate.

5.2 Sensörü Monte Etme

  1. Pozisyon Sensörü: Gently push the wired sensor into the electrical box, ensuring wires are not pinched.
  2. Secure Sensor: Use the supplied mounting screws to secure the sensor to the electrical box. The break-off bracket ears can be removed if needed for multi-gang installations.
  3. Duvar Plakasını Takın: Attach the decorative wall plate (not included with sensor, but required for finish) over the sensor.
  4. Gücü Geri Yükle: Devre kesiciden gücü tekrar AÇIN.

6. Kurulum ve Yapılandırma

Upon initial power-up, the sensor will enter a warm-up period. During this time, the LED indicator may flash. Once stable, the sensor is ready for configuration.

6.1 Ayarların Yapılması

The SWX-121-WH typically has default settings for sensitivity and time delay. Advanced settings may be accessible via specific button press sequences or external configuration tools (if applicable, not specified in product description). For basic operation, the sensor will automatically turn lights on when occupancy is detected and off after a set time delay when the space is vacant.

  • Zaman Gecikmesi: This setting determines how long the lights remain on after the last detected occupancy. Common settings range from 30 seconds to 30 minutes.
  • Hassasiyet: Adjusts the responsiveness of the PIR and acoustic sensors. Higher sensitivity detects minor movements and sounds, while lower sensitivity requires more significant activity.
  • Geçiş Modu: Some sensors offer a short time delay for brief occupancy, like walking through a hallway.

Consult the detailed programming guide or manufacturer's website for specific instructions on adjusting these parameters for your model.

7. Operasyon

The SENSORWORX SWX-121-WH operates primarily in an auto-on (occupancy) mode, providing hands-free lighting control.

7.1 Otomatik Çalışma

  • When a person enters the detection zone, the PIR sensor detects motion, and the acoustic sensor detects sound.
  • Upon detection, the lights will automatically turn ON.
  • As long as occupancy is maintained (through continued motion or sound), the lights will remain ON.
  • After the space becomes vacant for the set time delay, the lights will automatically turn OFF.

7.2 Manuel Geçersiz Kılma

The SWX-121-WH typically includes a manual override button on the faceplate. Pressing this button allows you to:

  • Turn lights ON manually if they are OFF (overriding occupancy).
  • Turn lights OFF manually if they are ON (overriding occupancy).

Note: Manual override behavior may vary. Some models revert to automatic operation after a period, while others maintain the manual state until another manual press or power cycle.

8. Bakım

The SENSORWORX SWX-121-WH is designed for minimal maintenance. Regular cleaning can help ensure optimal performance.

  • Temizlik: Periodically wipe the sensor lens and faceplate with a soft, damp cloth. Do not use abrasive cleaners, solvents, or harsh chemicals, as these can damage the surface or sensor components.
  • obstrüksiyonlar: Ensure that there are no obstructions (e.g., furniture, curtains, tall plants) blocking the sensor's field of view, as this can impair detection.
  • Toz Birikimi: Excessive dust on the sensor lens can reduce sensitivity. Clean as needed.

Always turn off power at the circuit breaker before cleaning or performing any maintenance that requires touching the sensor directly.

9. Sorun Giderme

If you experience issues with your SENSORWORX SWX-121-WH, refer to the following table for common problems and solutions.

SorunOlası NedenÇözüm
Işıklar otomatik olarak yanmaz.
  • Sensöre elektrik gelmiyor.
  • Yanlış kablolama.
  • Sensör merceği engellenmiş.
  • Sensitivity too low.
  • Sensor in manual OFF mode.
  • Devre kesiciyi kontrol edin.
  • Verify wiring connections (Line/Load/Neutral).
  • Sensörün önündeki tüm engelleri kaldırın. view.
  • Increase sensor sensitivity (refer to setup guide).
  • Press the manual override button to switch to auto mode.
Lights turn OFF too quickly or unexpectedly.
  • Time delay set too short.
  • Insufficient motion/sound detected.
  • Sensör merceği engellenmiş.
  • Increase the time delay setting.
  • Increase sensor sensitivity.
  • Ensure sensor has a clear line of sight and acoustic path.
Lights remain ON constantly.
  • Constant motion/sound detected.
  • Sensor in manual ON mode.
  • Arızalı sensör.
  • Check for sources of constant motion (e.g., HVAC vents, pets).
  • Press the manual override button to switch to auto mode or OFF.
  • Sorun devam ederse müşteri desteğiyle iletişime geçin.
LED göstergesi çalışmıyor.
  • Sensöre elektrik gelmiyor.
  • LED disabled (if configurable).
  • Arızalı cihaz.
  • Güç kaynağını kontrol edin.
  • Consult advanced settings for LED control.
  • Müşteri desteğiyle iletişime geçin.

10. Özellikler

ÖzellikDetay
Model NumarasıSWX-121-WH
MarkaSENSORWORX
TeknolojiPassive Infrared (PIR) & Acoustic
Cilttage120 / 277V AC
Sıklık50/60Hz
Load Rating (120VAC)800W
Load Rating (277VAC)1200W
Anahtar Yapılandırması1-Pole, Auto-On (Occupancy)
Algılama AralığıUp to 48 Feet (PIR)
Boyutlar (Y x G x D)2.74" x 1.68" x 1.39"
RenkBeyaz
Çalışma Sıcaklığı32°F ila 122°F (0°C ila 50°C)
Montaj TipiSurface Mount (Standard Wall Box)
Güç KaynağıKablolu Elektrik
Ürün Ağırlığı3.84 ons (0.24 Pound)
Yapıldığı YerAmerika

11. Garanti ve Destek

11.1 Garanti Bilgileri

The SENSORWORX SWX-121-WH Light Switch with Motion Sensor is backed by a 5 yıllık garanti from the date of purchase. This warranty covers defects in materials and workmanship under normal use. It does not cover damage resulting from improper installation, misuse, abuse, or unauthorized modifications.

Garanti talepleri için lütfen satın alma belgenizi saklayın.

11.2 Müşteri Desteği

For technical assistance, troubleshooting beyond this manual, or warranty inquiries, please contact SENSORWORX customer support:

  • Webalan: www.sensorworx.com
  • E-posta: support@sensorworx.com
  • Telefon: Please refer to the SENSORWORX webGüncel iletişim numaraları için siteyi ziyaret edin.

When contacting support, please have your product model number (SWX-121-WH) and date of purchase readily available.

© 2025 SENSORWORX. All rights reserved.

Bu kılavuzdaki bilgiler önceden haber verilmeksizin değiştirilebilir.

Ask a question about this manual