1. Giriş
This manual provides comprehensive instructions for the AUX DC Inverter Multi-Split Air Conditioner System, designed for efficient cooling and heating of multiple rooms. This system utilizes R-32 refrigerant and features advanced DC Inverter technology for optimal performance and energy savings. Please read this manual thoroughly before installation, operation, or maintenance to ensure correct usage and to prevent damage to the unit or injury to personnel.
2. Güvenlik Bilgileri
Always adhere to the following safety precautions to prevent electric shock, fire, injury, or damage to the unit:
- Installation must be performed by qualified and authorized personnel only, in accordance with national wiring regulations.
- Güç kaynağının ünitenin özelliklerine uygun olduğundan emin olun.
- Üniteyi kendiniz onarmaya veya değiştirmeye çalışmayın. Yetkili servis personeliyle iletişime geçin.
- Elektrik çarpmasını önlemek için topraklamanın uygun olduğundan emin olun.
- Do not block the air inlet or outlet of the indoor or outdoor units.
- Çalışma sırasında çocukları cihazdan uzak tutun.
- The refrigerant R-32 is mildly flammable. Handle with care and ensure proper ventilation during installation and servicing.
3. Paket İçeriği
Upon unpacking, verify that all components are present and undamaged. The standard package for the AUX DC Inverter Multi-Split Air Conditioner System (Trial 12+12+12) typically includes:
- One (1) Outdoor Unit (Model: AM4-H28/4DR3C)
- Three (3) Indoor Units (e.g., 12000 BTU units, or a combination of 9000 BTU and 12000 BTU units as per your specific order)
- Three (3) Remote Controls for Indoor Units
- Kullanım Kılavuzu ve Kurulum Kılavuzu
- Mounting accessories for indoor units
Note: Specific indoor unit models and quantities may vary based on the purchased configuration.
4. Özellikler
The following table outlines the key technical specifications for the AUX DC Inverter Multi-Split Air Conditioner System:
| Özellik | Şartname |
|---|---|
| Marka | Yardımcı |
| Dış Ünite Modeli | AM4-H28/4DR3C |
| Cooling Capacity (Total) | 29650 BTU |
| Heating Capacity (Total) | 30776 BTU |
| Güç Kaynağı | Single-phase 220-240V/1/50Hz |
| GÖREN | 6.3 |
| SCOP | 4.1 |
| Enerji Sınıfı | A++A+ |
| Soğutucu | R-32 |
| Outdoor Unit Airflow | 3100 m³/saat |
| Dış Ünite Ses Basıncı Seviyesi | 56 dB |
| Operating Limit (Temperature) | -35°C ile +55°C arası |
| Dış Ünite Boyutları (UxGxY) | 832x328x655 mm |
| Sıvı Hattı Boyutu | 1/4 inç |
| Gas Line Size | 3/8 inç |
| Maksimum Satır Uzunluğu | 70 metre |
| Maximum Single Line Length | 30 metre |
| Maximum Dislevel (Outdoor to Indoor) | 15 metre |
| Maximum Dislevel (Between Indoor Units) | 10 metre |
| Indoor Unit (9000 BTU) Cooling Capacity | 11260 BTU |
| Indoor Unit (9000 BTU) Heating Capacity | 11260 BTU |
| Indoor Unit (9000 BTU) Airflow | 800 m³/saat |
| Indoor Unit (9000 BTU) Dimensions (LxWxH) | 792x200x285 mm |
| Indoor Unit (9000 BTU) Connections | 1/4 inç, 3/8 inç |
| Indoor Unit (9000 BTU) Drain Diameter | 16.5 mm |
| Indoor Unit (9000 BTU) Minimum Noise Level | 19 dB |
| Indoor Unit (12000 BTU) Cooling Capacity | 12625 BTU |
| Indoor Unit (12000 BTU) Heating Capacity | 12966 BTU |
| Indoor Unit (12000 BTU) Airflow | 600 m³/saat |
| Indoor Unit (12000 BTU) Dimensions (LxWxH) | 750x200x285 mm |
| Indoor Unit (12000 BTU) Connections | 1/4 inç, 3/8 inç |
| Indoor Unit (12000 BTU) Drain Diameter | 16.5 mm |
| Indoor Unit (12000 BTU) Minimum Noise Level | 19 dB |
| Toplam Ağırlık | 120 kilo |
| Kontrol Türü | Uzaktan kumanda |
5. Kurulum
Installation of this multi-split air conditioning system requires specialized knowledge and tools. It must be performed by certified HVAC technicians.
5.1 Genel Yönergeler
- Lokasyon Seçimi: Choose a location for the outdoor unit that allows for adequate airflow and is away from direct sunlight or heat sources. Indoor units should be placed to ensure even air distribution.
- Montaj: Securely mount indoor and outdoor units according to the provided installation diagrams.
- Soğutucu Boruları: Connect the liquid and gas lines between the outdoor unit and each indoor unit. The system uses R-32 refrigerant, which operates at similar pressures to R410A. Ensure compatibility of tools (manifold gauge, leak detector, recovery unit) with R-32. R-32 is a pure gas, simplifying charging procedures compared to refrigerant mixtures.
- Drenaj: Install condensate drain pipes with proper slope to ensure efficient water removal.
- Elektrik Tesisatı: Connect the power supply and communication cables according to the wiring diagram. Ensure all connections are secure and properly insulated.
- Süpürme ve Şarj Etme: Evacuate the system to remove non-condensable gases and moisture. Charge with the correct amount of R-32 refrigerant.
For detailed installation steps, refer to the separate Installation Manual provided with the product.

6. Operasyon
Your AUX air conditioner system is controlled via a wireless remote control. Familiarize yourself with the remote control functions for optimal use.
6.1 Temel İşlemler
- Güç Açma/Kapatma: Üniteyi açmak veya kapatmak için uzaktan kumandadaki güç düğmesine basın.
- Mod Seçimi: Select desired operating mode (Cool, Heat, Fan, Dry, Auto) using the Mode button.
- Sıcaklık Ayarı: Use the temperature up/down buttons to set the desired room temperature.
- Fan Hızı: Adjust fan speed (Auto, Low, Medium, High) to your preference.
6.2 Gelişmiş İşlev
- 24 saatlik Zamanlayıcı: This function allows you to set a specific time for the air conditioner to turn on or off within a 24-hour period.
- Fonksiyonu Hissediyorum: When activated, the remote control's built-in temperature sensor measures the ambient temperature and sends the data to the indoor unit, allowing the unit to adjust its operation for enhanced comfort around the remote control's location.
- Süper Soğutma: Provides rapid cooling to quickly reach the desired temperature.
- Akıllı İşlev: Pressing the 'Smart' button on the remote control enables the air conditioner to operate in the most comfortable mode based on the current room temperature, automatically adjusting settings.
- Uyku Fonksiyonu: Optimizes temperature and fan speed settings during sleep for comfort and energy efficiency.
- Wi-Fi Kontrolü (İsteğe bağlı): If equipped with the optional Wi-Fi module, the system can be controlled remotely via a smartphone application. Refer to the Wi-Fi module manual for setup instructions.
7. Özellikler
The AUX DC Inverter Multi-Split Air Conditioner System incorporates several advanced features for superior performance and user experience:
- Full DC Inverter Technology: Features a digital control signal, DC Inverter compressor, DC Inverter motors on both indoor and outdoor units, and an electronic expansion valve. This ensures low noise levels and high efficiency.
- DC Inverter Twin Rotary Compressor: The newly designed BLDC Inverter twin rotary compressor provides improved balance and reduced vibrations, leading to maximum quietness and excellent efficiency and energy savings.
- Elektronik Genleşme Valfi: Precisely controls refrigerant flow for optimal system performance.
- Düşük Hacimtage İşlem: The outdoor unit can operate within a wide voltage range (176V to 264V), ensuring stable performance even with voltage dalgalanmalar.
- Auto-diagnosis and Automatic Protection: The system can detect operational anomalies and activate protective measures.
- Düşük Sıcaklıkta Isıtma: Capable of providing effective heating even at outdoor temperatures as low as -15°C.
- Otomatik buz çözücü: Automatically defrosts the outdoor unit coil to maintain heating efficiency in cold conditions.
- 8°C Yeniden Başlat: A function that maintains a minimum temperature of 8°C to prevent freezing in unoccupied rooms during winter.
- Anti-mold Function: After the air conditioner is turned off, the indoor fan continues to operate for 30 seconds to dry any condensation inside the indoor unit, preventing mold formation.
- Gelişmiş Filtrasyon: Includes an active carbon filter and a 4-in-1 filter system for improved air quality.
- Rubidium Magnet Compressor: Enhances efficiency and reduces power consumption through increased gas molecule compression.
- Optimized Heat Exchanger Design: The external heat exchanger is designed to maximize heat transfer, improving the refrigeration circuit's efficiency and preventing ice blockages. It also supports long-distance connections between units without reducing cooling capacity.
8. Bakım
Regular maintenance ensures the longevity and efficient operation of your air conditioning system. Always turn off the power supply before performing any maintenance.
8.1 İç Ünite Bakımı
- Filtre Temizleme: Clean the air filters every two weeks or more frequently depending on usage and air quality. Remove filters, wash with lukewarm water, dry thoroughly, and reinsert.
- Ünite Yüzey Temizliği: İç ünitenin yüzeyini yumuşak bir bezle silin.amp Bez kullanın. Sert deterjanlar veya aşındırıcı temizleyiciler kullanmayın.
- Anti-mold Function: Utilize the built-in anti-mold function to keep the indoor coil dry.
8.2 Dış Ünite Bakımı
- Bobin Temizliği: Periodically check and clean the outdoor unit's coil to remove dust, leaves, and other debris that can obstruct airflow. This should ideally be done by a professional.
- Engelleri Temizle: Dış ünitenin çevresinde hava akışını engelleyebilecek herhangi bir engel bulunmadığından emin olun.
8.3 Profesyonel Servis
It is recommended to have your system professionally serviced at least once a year by a qualified technician. This includes checking refrigerant levels, electrical connections, and overall system performance.
9. Sorun Giderme
Servis personeliyle iletişime geçmeden önce, lütfen tekrar iletişime geçin.view Aşağıdaki yaygın sorunlar ve bunların potansiyel çözümleri:
| Sorun | Olası Neden | Çözüm |
|---|---|---|
| Ünite açılmıyor | No power supply; Remote control batteries low; Circuit breaker tripped | Güç bağlantısını kontrol edin; Pilleri değiştirin; Devre kesiciyi sıfırlayın. |
| Yetersiz soğutma/ısıtma | Kirli hava filtreleri; Tıkalı dış ünite; Yanlış mod/sıcaklık ayarı; Düşük soğutucu akışkan | Clean filters; Clear obstructions; Adjust settings; Contact technician for refrigerant check |
| Olağandışı gürültü | Loose parts; Fan obstruction; Refrigerant flow noise (normal) | Check for loose parts; Clear obstructions; If persistent or loud, contact technician |
| İç üniteden su sızıntısı | Tıkalı gider borusu; Yanlış montaj | Clear drain pipe; Contact technician for inspection |
| Uzaktan kumanda çalışmıyor | Batteries low/dead; Obstruction between remote and unit | Pilleri değiştirin; görüş alanının açık olduğundan emin olun. |
The system features an auto-diagnosis function. If an error code appears on the display, consult the detailed troubleshooting section in the full user manual or contact customer support with the error code.
10. Garanti ve Destek
Your AUX DC Inverter Multi-Split Air Conditioner System is covered by a manufacturer's warranty.
- Factory Warranty: A 5-year factory warranty is provided for certain components.
- Ürün Garantisi: A general 2-year product warranty applies.
Please refer to your purchase documentation for specific warranty terms and conditions, as these may vary by region and retailer. For warranty claims, technical support, or service requests, please contact your authorized dealer or the AUX customer service department.