SKINACT SKU164247

SKINACT Bellage Electric Treatment Table (Chair)

Model: SKU164247

giriiş

Thank you for choosing the SKINACT Bellage Electric Treatment Table. This versatile and durable electric chair is designed for professional use in spa and medical environments, offering exceptional comfort and adjustability. Equipped with four independent electric motors, it allows for precise positioning of the backrest, leg rest, seat tilt, and overall height, ensuring optimal client comfort and practitioner convenience. This manual provides essential information for the safe and effective setup, operation, and maintenance of your new treatment table.

Diagram showing the various adjustable parts of the SKINACT Bellage Electric Treatment Table, including removable headrest, armrests, foot rest extension, and electric adjustments for backrest, leg rest, seat tilt, and height.

Şekil 1: Üzeriview of the SKINACT Bellage Electric Treatment Table with key features labeled.

Güvenlik Bilgileri

Please read all safety warnings and instructions carefully before assembly and operation. Failure to do so may result in injury or damage to the product. Ensure the table is placed on a stable, level surface. Keep hands and loose clothing clear of moving parts during operation. Do not exceed the maximum weight capacity of 350 lbs. Disconnect power before performing any maintenance or cleaning.

Kurmak

1. Paketin Açılması ve Yerleştirilmesi

  • Tüm bileşenleri dikkatlice ambalajından çıkarın.
  • Place the base of the treatment table on a firm, level floor. Ensure there is sufficient clear space around the table for full range of motion and safe operation.
  • Verify all leveling feet on the base are properly adjusted to ensure stability.

2. Bileşen Montajı

  • Attach Headrests: The Bellage table comes with two different headrests. Select the appropriate headrest for your procedure and securely attach it to the head section of the table. One headrest includes a breather hole for clients lying face down.
  • Kolçakları takın: Slide the removable armrests into their designated slots on the sides of the main body of the chair.
  • Foot Rest Extension: The foot rest section can be extended as needed.
Two different headrests for the treatment table, one with a breather hole, shown next to the table's head section.

Figure 2: The two interchangeable headrests provided with the table.

3. Güç Bağlantısı

  • Locate the power cord and plug it securely into the power input on the table's base.
  • Plug the other end of the power cord into a grounded electrical outlet (100-120 volts, 50-60 hertz).

4. Uzaktan Kumanda Bağlantısı

  • Connect the remote control cable to the designated port on the underside of the table.
Wired remote control for the electric treatment table, showing buttons for various adjustments.

Figure 3: The wired remote control for the Bellage Electric Treatment Table.

Kurulum Tanıtım Videosu

Video 1: A demonstration of the Bellage Electric Treatment Table's features and adjustments.

Kullanım Talimatları

The SKINACT Bellage Electric Treatment Table is operated using the wired remote control. Each button on the remote corresponds to a specific motor, allowing for independent adjustment of different sections of the table.

1. Güç Açma/Kapatma

  • Basın Güç button (usually indicated by a circle with a vertical line) on the remote to turn the table on or off.

2. Yüksekliği Ayarlama

  • Kullanın Yukarı/Aşağı oklar associated with the overall table icon to raise or lower the table's height. The height can be adjusted between 25.5 and 31.5 inches.
Diagram showing the electric treatment table adjusting its height upwards and downwards.

Figure 4: Electric height adjustment.

3. Adjusting Backrest Angle

  • Kullanın Yukarı/Aşağı oklar associated with the backrest icon to adjust the backrest angle from 0° to 80° incline.
Diagram showing the electric treatment table's backrest adjusting from a flat position to an inclined position.

Figure 5: Electric backrest adjustment.

4. Adjusting Leg Rest Angle

  • Kullanın Yukarı/Aşağı oklar associated with the leg rest icon to adjust the leg rest angle from 0° to 85° decline.
Diagram showing the electric treatment table's leg rest adjusting from a flat position to a declined position.

Figure 6: Electric leg rest adjustment.

5. Adjusting Bed Tilt Angle

  • Kullanın Yukarı/Aşağı oklar associated with the full bed tilt icon to adjust the entire bed's tilt angle from 0° to 10°.
Diagram showing the electric treatment table tilting from a flat position to an inclined position.

Figure 7: Electric bed tilt adjustment.

6. Memory Presets (P1, P2, P3)

  • The remote control may feature preset buttons (P1, P2, P3) to save and recall preferred positions. Consult the remote's specific instructions for programming these presets.

Bakım

Regular maintenance ensures the longevity and optimal performance of your SKINACT Bellage Electric Treatment Table.

  • Temizlik: Wipe the surfaces of the table with a dry cloth. For deeper cleaning, use a mild, non-abrasive cleaner and a soft cloth. Avoid harsh chemicals or abrasive materials that could damage the upholstery or frame.
  • Denetleme: Periodically inspect all electrical cords, connections, and moving parts for any signs of wear, damage, or loose fittings. If any issues are found, discontinue use and contact customer support.
  • Yağlama: The electric motors and moving mechanisms are generally maintenance-free. Do not attempt to lubricate internal components unless specifically instructed by a qualified technician.

Sorun giderme

If you encounter any issues with your treatment table, refer to the following common troubleshooting steps:

SorunOlası NedenÇözüm
Table does not respond to remote control.No power; Loose connection; Remote control malfunction.Check if the power cord is securely plugged into the outlet and the table. Ensure the remote control cable is firmly connected. Try a different outlet. If the issue persists, contact customer support.
Motor makes unusual noise or movement is jerky.Tıkanma; Motor sorunu.Check for any obstructions preventing smooth movement. Ensure the table is not overloaded. Discontinue use and contact customer support if the noise or jerky movement continues.
Table is unstable or wobbles.Uneven floor; Unadjusted leveling feet.Ensure the table is on a flat, level surface. Adjust the leveling feet on the base until the table is stable.

Özellikler

ÖzellikDetay
MarkaSKINACT
Model NumarasıÜrün Kodu164247
MalzemeMetal frame, plastic cover, Foam, PU upholstery
RenkKoyu Gri
Ürün Ağırlığı200 pound
Ürün Boyutları (U x G x Y)68 x 28 x 32 inç
Length (with headrest)76.8 inç
Yükseklik Aralığı25.5 / 31.5 inç
Width (with armrests)35.4 inches (24.8 inches without armrests)
Sırtlık Açısı0° to 80° incline
Bed Tilt Angle0° ila 10°
Leg Rest Angle0° to 85° decline
Güç Gereksinimleri100-120 volts, 50-60 hertz, 200 watts, 2 amp
Maksimum Ağırlık Kapasitesi350 lbs.
Diagram showing detailed dimensions of the SKINACT Bellage Electric Treatment Table in both chair and flat positions.

Figure 8: Detailed dimensions of the treatment table.

Garanti ve Destek

The SKINACT Bellage Electric Treatment Table comes with a BİR YIL GARANTİ Satın alma tarihinden itibaren geçerlidir. Bu garanti, üretim hatalarını ve normal kullanım koşullarındaki arızaları kapsar.

For technical support, warranty claims, or any questions regarding your product, please contact SKINACT customer service. Refer to your purchase documentation for specific contact details or visit the official SKINACT webalan.

© 2024 SKINACT. All rights reserved.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.