ASD A-BLD-HM08D

ASD Battery Back-Up Kit 8W Instruction Manual

Model: A-BLD-HM08D

1. Giriş

Thank you for choosing the ASD Battery Back-Up Kit 8W. This emergency battery back-up unit is designed to provide reliable power to compatible LED commercial downlights (such as ASD-CDL7, CD-P, CD-T) for 90 minutes during a power outage. It features a durable lithium-ion battery, multi-protection functions, and an automatic self-testing capability to ensure continuous readiness. This manual provides essential information for safe installation, operation, and maintenance of your device.

ASD Battery Back-Up Kit 8W and test switch

Image 1.1: The ASD Battery Back-Up Kit 8W, showing the emergency LED driver and the charging indicator/test switch.

2. Güvenlik Bilgileri

Please read all instructions carefully before installation and operation. Failure to follow these instructions may result in electric shock, fire, or other hazards. Keep this manual for future reference.

  • UYARI: Elektrik çarpması riski. Kurulum veya bakım işlemlerinden önce elektriği kesin.
  • Installation should be performed by a qualified electrician in accordance with the National Electrical Code (NEC) and local code requirements.
  • Do not use this device with dimmers unless explicitly stated as compatible.
  • Tüm bağlantıların güvenli ve düzgün bir şekilde yalıtıldığından emin olun.
  • Do not modify or disassemble the unit. There are no user-serviceable parts inside.
  • Bu ürün d'dir.amp-rated. Do not expose to direct water spray or submersion.
  • Operating temperature range must be observed to ensure proper function and battery life.

3. Ürün Özellikleri

The ASD Battery Back-Up Kit 8W is engineered with several key features to provide reliable emergency lighting:

  • Acil durum operasyonu: Provides 90 minutes of constant output power to the connected LED fixture during a power outage.
  • Dayanıklı Pil: Equipped with a long-lasting lithium-ion battery designed for 5000 cycles of standard charge and discharge.
  • Çoklu Koruma Fonksiyonları: Includes overcharge protection, over-discharge protection, short circuit protection, and over-temperature protection for enhanced safety and durability.
  • Self-Checking Option: Automatically performs a monthly self-test (30 seconds duration) and an annual self-test (90 minutes duration) to verify emergency function and battery capacity.
  • Mod Göstergesi: A clear indicator allows users to easily see whether the unit is operating in back-up mode or AC mode.
  • Kolay Kurulum: Designed for direct connection to the AC input of the fixture, simplifying the installation process.
  • UL Sertifikalı: Güvenlik standartlarına uyumu sağlar.
Features of ASD Battery Back-Up Kit

Image 3.1: Visual representation of key features including 90 minutes emergency mode, indicator, self-testing, and multi-protection.

4. Özellikler

Detailed technical specifications for the ASD Battery Back-Up Kit 8W:

Şartname Değer
Marka otizm spektrum bozukluğu
Model Numarası A-BLD-HM08D
Netage 8W
Acil Durum Süresi 90 dakikadır.
Pil Döngüleri 5000 cycles (charge/discharge)
Cilttage 120-347 Volt
Ürün Boyutları 10.43 x 1.97 x 0.95 inç
Ürün Ağırlığı 2 pound
Malzeme Ütü
Sertifikalar UL Sertifikalı
Konum Derecelendirmesi Damp Derecelendirildi
Ürün boyutları ve özellikleri

Image 4.1: Detailed product dimensions and key specifications.

5. Kurulum

Follow these steps for proper installation of the battery back-up kit. Ensure power is disconnected before beginning.

  1. Secure the Battery Back-Up Kit: Securely mount the battery back-up unit to the ceiling structure or within an accessible junction box, ensuring it is stable and properly supported.
  2. Kabloları Bağlayın: Refer to the electrical diagram below for wiring connections. Connect the battery back-up unit to the fixture and the main power supply. Ensure all connections are tight and insulated.
  3. Install Test Switch: Connect the test switch to the battery back-up unit and affix it in a visible and accessible location on the surface, typically a wall plate.
  4. Gücü Geri Yükle: Once all connections are verified and secure, restore power to the circuit. The unit will begin charging.
Installation steps for battery back-up kit

Image 5.1: Visual guide for securing the unit and connecting wires.

Electrical wiring diagram for battery back-up kit

Image 5.2: Detailed electrical wiring diagram for connecting the battery back-up, fixture, and driver.

6. Operasyon

Once installed and powered, the ASD Battery Back-Up Kit operates automatically:

  • Normal Operation (AC Mode): When AC power is present, the unit charges its internal battery and the connected LED fixture operates normally. The mode indicator will show the AC mode status (e.g., green light).
  • Emergency Operation (Back-Up Mode): Bir elektrik kesintisi durumundatage, the unit automatically switches to battery back-up mode, providing emergency power to the connected fixture for 90 minutes. The mode indicator will change to reflect back-up mode (e.g., red light).
  • Kendi Kendine Test:
    • Monthly Self-Test: The battery automatically performs a 30-second self-test every 30 days to check if the emergency function is normal.
    • Annual Self-Test: An annual 90-minute self-test is performed to check the capacity of the battery pack.
  • Manuel Test: Press the test button on the charging indicator/test switch to manually initiate a brief test of the emergency function.
Back-up or AC mode indicator

Image 6.1: The charging indicator/test switch showing the operational status.

Regular self-testing feature

Image 6.2: Illustration of the regular self-testing function.

7. Bakım

The ASD Battery Back-Up Kit requires minimal maintenance due to its self-testing capabilities. However, regular visual inspections are recommended:

  • Görsel Muayene: Periodically check the unit and wiring for any signs of damage, wear, or loose connections.
  • Gösterge Kontrolü: Ensure the mode indicator light is functioning correctly and displays the appropriate status (AC mode or back-up mode during a test).
  • Temizlik: Gerekirse, cihazın dış yüzeyini kuru, yumuşak bir bezle nazikçe silin. Aşındırıcı temizleyiciler veya çözücüler kullanmayın.
  • Pil Değişimi: The battery is designed for long life. If the unit consistently fails self-tests or does not provide the rated emergency duration, the unit may need replacement. Contact customer support for assistance.

8. Sorun Giderme

If you encounter issues with your ASD Battery Back-Up Kit, refer to the following common problems and solutions:

Sorun Olası Neden Çözüm
Unit does not charge / Indicator light off No AC power; Loose wiring; Faulty unit. Check circuit breaker; Verify all wiring connections; Contact customer support if power is present and connections are secure.
Fixture does not illuminate in emergency mode Battery not charged; Incompatible fixture; Faulty unit. Allow 24 hours for initial charge; Ensure fixture is compatible (0/1-10V dimming, up to 150W); Perform manual test; Contact customer support.
Emergency duration is less than 90 minutes Battery degradation; High ambient temperature. Ensure unit is within recommended operating temperature; Unit may need replacement if battery is degraded.
Self-test fails Battery issue; Internal fault. Ensure unit has been fully charged; Contact customer support for diagnosis and potential replacement.

9. Garanti ve Destek

ASD sağlar 5 yıllık sınırlı garanti for the Battery Back-Up Kit 8W, guaranteeing top quality products and safety. This warranty covers defects in materials and workmanship under normal use and service.

For technical support, warranty claims, or any questions regarding your product, please contact ASD customer support. Our team is committed to responding to your concerns within 24 hours.

İletişim Bilgileri: Lütfen üreticinin webEn güncel iletişim bilgileri için site veya ürün ambalajına bakın.

© 2024 ASD Lighting Corp. All rights reserved.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.