EVURU 2/2 DN25 SS Electric Water Valve Instruction Manual

Model: 2W-25B EPDM

1. Giriş

This manual provides essential information for the safe and efficient installation, operation, and maintenance of your EVURU 2/2 DN25 Stainless Steel Electric Water Valve. This valve is a normally closed, direct-acting solenoid valve designed for controlling the flow of water, gas, or liquid in various applications.

Please read this manual thoroughly before installation and operation to ensure proper function and to prevent damage or injury. Keep this manual for future reference.

2. Güvenlik Bilgileri

UYARI: Failure to follow these safety instructions may result in property damage, serious injury, or death.

  • Always disconnect power before installing, servicing, or cleaning the valve.
  • Vol'ün sağlandığından emin oluntage supply matches the valve's specified voltage (e.g., AC220V, DC12V). Incorrect voltage can damage the valve or cause electrical hazards.
  • Installation should be performed by qualified personnel in accordance with local electrical and plumbing codes.
  • Do not exceed the maximum working pressure specified for the valve.
  • Ensure the media (water, gas, liquid) and its temperature are within the valve's specified limits.
  • Kurulum ve bakım sırasında uygun kişisel koruyucu ekipman (KKD) giyin.
  • Avoid exposing the valve to corrosive environments or extreme temperatures outside its operating range.

3. Ürün Bittiview

The EVURU 2/2 DN25 SS Electric Water Valve is a robust solenoid valve constructed from Stainless Steel 304, designed for reliable flow control. It features a 1-inch pipe size (DN25) and is available with BSP or NPT threads. The valve operates as normally closed, meaning it remains closed when de-energized and opens when energized.

Assembled EVURU 2/2 DN25 SS Electric Water Valve with black solenoid coil and red wires.

Figure 1: Assembled EVURU 2/2 DN25 SS Electric Water Valve. This image shows the complete valve unit, including the stainless steel body, the black solenoid coil, and the red electrical wires.

4. Kurulum ve Kurulum

4.1 Kurulum Öncesi Kontroller

  • Verify that the valve specifications (voltage, pressure, media, temperature) match your application requirements.
  • Inspect the valve for any visible damage from shipping.
  • Ensure the piping system is clean and free of debris that could obstruct valve operation.

4.2 Mekanik Kurulum

  1. Turn off the main power supply and shut off the fluid flow to the installation area.
  2. Identify the inlet and outlet ports on the valve body. Flow direction is typically indicated by an arrow on the valve body.
  3. Apply appropriate thread sealant (e.g., PTFE tape or pipe dope) to the pipe threads.
  4. Thread the valve onto the pipes, ensuring a tight, leak-free connection. Do not overtighten.
  5. Mount the valve in a position that allows for easy access for maintenance and inspection. The solenoid coil should ideally be in an upright position to prevent accumulation of debris and ensure proper operation.

4.3 Elektrik Bağlantısı

  1. Güç kaynağı bağlantısının kesildiğinden emin olun.
  2. Connect the valve's electrical wires to the appropriate power source. Refer to the voltage specified on the solenoid coil.
  3. Kısa devreleri veya elektrik tehlikelerini önlemek için tüm elektrik bağlantılarının güvenli ve uygun şekilde yalıtıldığından emin olun.
  4. If applicable, connect the ground wire according to local electrical codes.
Disassembled EVURU 2/2 DN25 SS Electric Water Valve showing body, coil, and nut.

Figure 2: Disassembled EVURU 2/2 DN25 SS Electric Water Valve components. This image displays the main stainless steel valve body, the separate solenoid coil, and the retaining nut, illustrating how the coil attaches to the valve stem.

5. Kullanım Talimatları

The EVURU 2/2 DN25 SS Electric Water Valve is a normally closed (N/C) valve, meaning it is closed by default when no power is applied to the solenoid coil.

  1. Vanayı Açmak İçin: Apply the specified electrical voltage to the solenoid coil. The coil will energize, lifting the plunger and opening the valve, allowing fluid to flow.
  2. Vanayı kapatmak için: Disconnect the electrical voltage from the solenoid coil. The coil will de-energize, and the plunger will return to its closed position, stopping the fluid flow.

Ensure that the system pressure and fluid temperature remain within the valve's specified operating limits during operation.

6. Bakım

Regular maintenance helps ensure the longevity and reliable operation of your valve.

  • Periyodik muayene: Regularly check for any signs of leaks around the valve body and connections. Inspect the electrical wiring for damage or loose connections.
  • Temizlik: If the valve is operating in an environment with particulate matter, periodic cleaning of the internal components may be necessary. Always disconnect power and depressurize the system before disassembling the valve.
  • Conta Değişimi: Over time, the EPDM seals may wear out. If leaks occur or the valve fails to seal properly, the seals may need to be replaced. Refer to Figure 2 for component identification.
  • Bobin Muayenesi: Ensure the solenoid coil is free from excessive heat, moisture, or physical damage.

Note: For complex repairs or internal component replacement, it is recommended to consult a qualified technician or the manufacturer.

7. Sorun Giderme

Sorun Olası Neden Çözüm
Enerji verildiğinde vana açılmıyor.
  • No power to the coil.
  • Yanlış cilttage.
  • Coil damaged or burnt out.
  • Debris obstructing plunger.
  • Excessive pressure differential.
  • Güç kaynağını ve bağlantılarını kontrol edin.
  • hacmi doğrulayıntage matches valve specification.
  • Bobini değiştirin.
  • Disassemble and clean valve internals.
  • Ensure operating pressure is within limits.
Enerji kesildiğinde vana kapanmıyor.
  • Debris lodged in valve seat.
  • Damaged or worn seal.
  • Spring failure.
  • Disassemble and clean valve internals.
  • Contaları değiştirin.
  • Replace valve or internal components.
Leakage from valve body or connections.
  • Loose pipe connections.
  • Damaged or worn seals.
  • Cracked valve body.
  • Tighten connections, reapply thread sealant.
  • Contaları değiştirin.
  • Valfi değiştirin.
Coil overheating.
  • Yanlış cilttage.
  • Continuous operation beyond duty cycle (if applicable).
  • Dahili kısa devre.
  • hacmi doğrulayıntage.
  • Ensure valve is suitable for continuous duty or adjust operation.
  • Bobini değiştirin.

8. Özellikler

Örnek 2W-25B EPDM
Boru Boyutu 1 inch (DN25)
Konu Tipi BSP, NPT
Medya Water, Gas, Liquid
Tip Normally Closed (N/C), Direct Acting
Working Pressure (Water, Air) 0-10 bar
Working Pressure (Oil) 0-7 bar
Cilttage Seçenekler AC240V, AC220V, AC120V, AC110V, AC24V, DC24V, DC12V (±10% tolerance)
Malzeme Paslanmaz Çelik 304
Mühür Malzemesi EPDM
Medium Temperature (EPDM) -5 ila 120 °C (23 ila 248 °F)
Ürün Ağırlığı 1 Grams (Note: This value seems unusually low and may be a placeholder. Refer to actual product for accurate weight.)

9. Garanti Bilgileri

Specific warranty details for the EVURU 2/2 DN25 SS Electric Water Valve are not provided in this manual. For information regarding product warranty, please refer to the purchase documentation, contact your retailer, or visit the official EVURU webalan.

10. Müşteri Desteği

If you encounter any issues or have questions not covered in this manual, please contact your product supplier or the manufacturer's customer support. When contacting support, please have your product model number (2W-25B EPDM) and purchase details readily available.

© 2023 EVURU. All rights reserved.