SKINACT 164242
SKINACT Bellage Electric Treatment Table (Chair) User Manual
Modeli: 164242
giriiş
This manual provides essential information for the safe and effective operation and maintenance of your SKINACT Bellage Electric Treatment Table. Please read this manual thoroughly before initial use and keep it for future reference.
The SKINACT Bellage Electric Treatment Table is a versatile, electrically adjustable chair designed for professional use in salons, spas, and medical offices. It features four independent motors for precise positioning of the backrest, leg rest, seat tilt, and overall height, ensuring optimal comfort for clients and ergonomic convenience for practitioners.

Figure 1: SKINACT Bellage Electric Treatment Table (Beige)
Güvenlik Bilgileri
Adherence to these safety guidelines is crucial for preventing injury and damage to the equipment.
- Do not use near water or in excessively damp ortamlar.
- Çocukların erişemeyeceği yerde saklayınız.
- Avoid using harsh chemicals or abrasive cleaners on any part of the table.
- Always unplug the device from the power outlet before performing any adjustments, cleaning, or maintenance.
- 300 lbs (136 kg) olan maksimum ağırlık sınırını aşmayın.
- Ensure all electrical connections are secure and undamaged before operation.
- Do not operate the chair if any part is damaged or malfunctioning. Contact customer support immediately.
Kurmak
The SKINACT Bellage Electric Treatment Table typically arrives pre-assembled or requires minimal assembly. Follow these general steps for initial setup:
- Carefully remove all packaging materials. Inspect the table for any signs of shipping damage.
- Place the table on a stable, level surface. Ensure adequate space around the table for full range of motion and safe operation.
- Connect the power cord to a grounded electrical outlet (100-120 volts, 50-60 hertz).
- Connect the wired remote control and any optional foot controls to their respective ports on the table's base.
- Adjust the leveling feet on the base to ensure the table is perfectly stable and does not wobble.
- Attach the desired headrest (with or without face hole) and armrests as needed.

Figure 2: Key Features and Electric Adjustments
Kullanım Talimatları
The SKINACT Bellage Electric Treatment Table offers multiple points of adjustment for optimal client comfort and practitioner convenience. All adjustments are controlled via the wired remote control or optional foot controls.
Uzaktan Kumandayı Kullanma
The wired remote control features intuitive buttons for each adjustable section of the chair. Familiarize yourself with the button layout:
- Yükseklik Ayarı: Use the up/down arrows to raise or lower the entire table.
- Sırt Açısı: Adjust the backrest from 0° to 80° incline.
- Leg Rest Angle: Adjust the leg rest from 0° to 85° decline.
- Seat Tilt Angle: Adjust the bed tilt angle from 0° to 10°.

Figure 3: Wired Remote Control
Adjusting Table Sections
- Sırtlık Ayarı: Use the corresponding buttons on the remote to raise or lower the backrest.

Figure 4: Headrest without Face Hole
- Bacak Desteği Ayarı: Use the corresponding buttons on the remote to adjust the leg rest angle. The leg rest also features an extension for added length.

Figure 5: Leg Rest Adjustment
- Yükseklik Ayarı: Use the remote to raise or lower the entire table to your desired working height.

Şekil 6: Yükseklik Ayarı
- Armrest and Headrest Removal: Armrests and headrests are removable for versatility.

Figure 7: Armrest Removal

Figure 8: Headrest Removal
Bakım
Proper maintenance ensures the longevity and optimal performance of your treatment table.
- Temizlik: Wipe the surface with a dry cloth. For deeper cleaning, use a mild, non-abrasive cleaner specifically designed for PU upholstery. Avoid harsh chemicals.
- Denetleme: Regularly inspect all moving parts, electrical cords, and connections for wear or damage.
- Yağlama: Moving parts may require periodic lubrication. Consult a qualified technician if you notice any stiffness or unusual noises during operation.
- Depolamak: When not in use for extended periods, store the table in a clean, dry environment, away from direct sunlight and extreme temperatures.
Sorun giderme
If you encounter issues with your SKINACT Bellage Electric Treatment Table, try these basic troubleshooting steps before contacting support:
- Table Not Responding:
- Check if the power cord is securely plugged into both the table and the wall outlet.
- Duvar prizinin çalışır durumda olduğundan emin olmak için başka bir cihazla test edin.
- Verify that the remote control and foot controls are properly connected.
- Çalışma Sırasında Olağandışı Sesler:
- Ensure no objects are obstructing the moving parts of the table.
- If noises persist, contact customer support; do not attempt to disassemble the motors.
- Aralıklı İşlevsellik:
- Tüm kablo bağlantılarında gevşeklik veya hasar olup olmadığını kontrol edin.
- Avoid overloading the table beyond its specified weight capacity.
Bu adımlarla çözülemeyen sorunlar için lütfen Garanti ve Destek bölümüne bakın.
Özellikler
| Özellik | Detay |
|---|---|
| Marka | SKINACT |
| Model Numarası | 164242 |
| Ürün Boyutları (U x G x Y) | 68 x 28 x 32 inç |
| Length (with headrest) | 76.8 inç |
| Yükseklik Aralığı | 25.5 - 31.5 inç |
| Width (with armrests) | 35.4 inç |
| Sırtlık Açısı | 0° to 80° incline |
| Bed Tilt Angle | 0° ila 10° |
| Leg Rest Angle | 0° to 85° decline |
| Taban Boyutları | 36" U x 23" G |
| Güç Gereksinimleri | 100-120 volts, 50-60 hertz, 200 watts, 2 amp |
| Malzeme | Metal frame, plastic cover, foam, PU upholstery |
| Ürün Ağırlığı | 200 pound |
| Maksimum Kapasite | 350 kilo |
| Renk | Bej |
| Menşei ülke | Çin |

Şekil 9: Detaylı Boyutlar ve Kapasite
Garanti ve Destek
Your SKINACT Bellage Electric Treatment Table comes with a BİR YIL GARANTİ covering manufacturing defects and malfunctions under normal use.
For warranty claims, technical assistance, or any questions regarding your product, please contact SKINACT Customer Support. You can find contact information on the official SKINACT websiteniz veya satın alma platformunuz aracılığıyla.
Additional protection plans may be available for purchase to extend coverage beyond the standard warranty period. Please refer to your purchase details for more information on available protection plans.
Ask a question about this manual
Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.