Kohler 26299-CP

Kohler Statement Round Deep Massage Body Spray (Model K-26299-CP) Instruction Manual

Polished Chrome, 2.5 GPM

1. Giriş

This manual provides detailed instructions for the installation, operation, and maintenance of your Kohler Statement Round Deep Massage Body Spray. Please read this manual thoroughly before installation and use to ensure proper function and longevity of the product.

Kohler Statement Round Deep Massage Body Spray, Polished Chrome

Figure 1: Kohler Statement Round Deep Massage Body Spray in Polished Chrome.

2. Güvenlik Bilgileri

Always observe basic safety precautions when installing or servicing plumbing fixtures. Failure to follow these instructions could result in personal injury or property damage.

  • Herhangi bir kurulum veya bakım işlemine başlamadan önce su kaynağının kapatıldığından emin olun.
  • Koruyucu gözlük gibi uygun kişisel koruyucu ekipman kullanın.
  • Kurulumun herhangi bir aşamasından emin değilseniz, yetkili bir tesisatçıya danışın.
  • Do not use abrasive cleaners or tools that could damage the finish of the product.

3. Kurulum ve Kurulum

3.1 Dahil Edilen Bileşenler

  • Statement Round Deep Massage Body Spray unit
  • Installation hardware (varies by model, refer to packaging)

3.2 Kurulum Adımları

The Kohler Statement Round Deep Massage Body Spray is designed for wall-mounted installation. For detailed diagrams and specific measurements, refer to the installation guide provided with your product packaging.

  1. Duvarı Hazırlayın: Ensure the wall opening is correctly sized and positioned according to the product's rough-in specifications.
  2. Su Temini Bağlantısı: Connect the hot and cold water supply lines to the body spray unit. Ensure all connections are secure and watertight.
  3. Üniteyi Monte Edin: Insert the body spray unit into the wall opening. Secure it using the provided mounting hardware.
  4. Kenarları Kapatın: Apply a silicone sealant around the perimeter of the body spray to prevent water infiltration.
  5. Sızıntı Testi: Su musluğunu açın ve herhangi bir sızıntı olup olmadığını kontrol edin.
Taraf view of Kohler Statement Body Spray showing mounting

Şekil 2: Yan view of the body spray, illustrating its semi-recessed design for wall mounting.

Diagram of Kohler Statement Body Spray features and dimensions

Figure 3: Detailed diagram highlighting key features such as the Deep Massage streams, MasterClean sprayface, and 20-degree rotation.

4. Operasyon

The Kohler Statement Round Deep Massage Body Spray features a single function with four high-pressure Deep Massage streams. It is designed to provide a targeted hydrotherapy experience.

  • Activating the Spray: The body spray is activated via your shower's diverter or valve system. Consult your shower valve's manual for specific operation.
  • Adjusting Spray Direction: The sprayface is mounted on a rotating ball joint, allowing it to rotate 20 degrees in any direction. Gently adjust the sprayface to direct the Deep Massage streams to your desired area.

Video 1: Demonstration of Kohler Statement Spray Experiences, showcasing various spray patterns including deep massage. This video illustrates the functionality and feel of the spray.

5. Bakım ve Temizlik

Regular cleaning will help maintain the appearance and performance of your body spray. The MasterClean™ sprayface is designed for easy cleaning and resists mineral buildup.

  • Genel Temizlik: Ürünü yumuşak, damp cloth and a mild soap. Rinse thoroughly with warm water and dry with a soft cloth.
  • Mineral Oluşumu: For mineral deposits, gently rub the MasterClean™ sprayface nozzles with your finger or a soft brush to dislodge any buildup. Avoid harsh chemicals or abrasive cleaners, as these can damage the finish.
  • Kullanmayın: Abrasive cleaners, scouring pads, or chemicals containing ammonia, bleach, or acid.

6. Sorun Giderme

SorunOlası NedenÇözüm
Düşük su akışıMineral buildup in nozzles; partially closed water supply valve.Clean MasterClean™ sprayface nozzles. Ensure water supply valve is fully open.
Bağlantılardan sızıntıGevşek bağlantılar; hasarlı contalar.Tighten connections. Inspect and replace seals if necessary. Ensure proper use of plumber's tape or sealant during installation.
Spray direction difficult to adjustMineral buildup around the ball joint.Clean around the ball joint with a soft cloth and mild cleaner to remove any deposits.

7. Özellikler

ÖzellikDetay
Model NumarasıK-26299-CP
MarkaKöhler
Akış Hızı2.5 GPM (Dakikada Galon)
MalzemePirinç, Plastik
Bitiş TürüCilalı Krom
Kurulum TürüDuvara Monte
Ayar Sayısı1 (Deep Massage)
Jet Sayısı4 (Deep Massage streams)
ŞekilYuvarlak
UPC885612882691

8. Garanti ve Destek

8.1 Garanti Bilgileri

This Kohler Statement Round Deep Massage Body Spray is covered under Kohler's limited lifetime warranty. For full details regarding warranty coverage, terms, and conditions, please refer to the warranty documentation included with your product or visit the official Kohler webalan.

8.2 Müşteri Desteği

If you have any questions, require technical assistance, or need to order replacement parts, please contact Kohler customer service. Contact information can be found on the Kohler websitenizde veya ürününüzün ambalajında.

Çevrimiçi Kaynaklar: www.kohler.com

© 2024 Kohler Co. Tüm hakları saklıdır. Bilgiler önceden haber verilmeksizin değiştirilebilir.