DEVMO DC 5V/12V 1 Channel Relay Board (Model JZ801) User Manual

Programmable Multifunctional Module Cycle Timing Circuit Switch

1. Giriş

This manual provides detailed instructions for the DEVMO DC 5V/12V 1 Channel Relay Board, Model JZ801. This programmable multifunctional module is designed for various timing and control applications, offering flexible operation modes and robust performance.

Temel özellikler şunlardır:

  • Geniş giriş hacmitage range: 6-30V, with micro USB 5.0V power supply option.
  • Adjustable timing range: 0.1 seconds to 999 minutes.
  • yüksek hacimtage level trigger (3.0V-24V).
  • Output capability: DC 0-30V 5A or AC 0-220V 5A.
  • Opto-isolator for enhanced anti-interference.
  • Reverse connect protection.
  • Automatic parameter saving upon power-off.
  • Sleep mode for power saving.

2. Paket İçeriği

Lütfen paketinizde tüm öğelerin mevcut olduğundan emin olun:

  • 1x DEVMO 1 Channel Multi-functional Time Delay Relay Board (blue board)
  • 1x USB to Micro USB Power Line
DEVMO JZ801 Relay Board with included USB cable

Figure 2.1: DEVMO JZ801 Relay Board and USB to Micro USB Power Line.

This image displays the DEVMO JZ801 1 Channel Relay Board, a blue circuit board with a 3-digit LED display, three control buttons (SET, STOP), a relay, and screw terminals for connections. A blue USB to Micro USB cable is also shown alongside the board.

3. Ürün Bittiview ve Bağlantılar

Familiarize yourself with the components and connection points of the relay board.

Tepe view of DEVMO JZ801 Relay Board

Şekil 3.1: Üst view of the DEVMO JZ801 Relay Board.

Bu görüntü, yukarıdan aşağıya doğru net bir bakış açısı sunmaktadır. view of the blue DEVMO JZ801 relay board, highlighting the 3-digit LED display, the three push buttons (SET, STOP, and one unmarked), the relay component, and the screw terminals for power input and relay output.

Alt view of DEVMO JZ801 Relay Board showing JZ-801 marking

Şekil 3.2: Alt view of the DEVMO JZ801 Relay Board.

This image shows the underside of the DEVMO JZ801 relay board, revealing the solder points, circuit traces, and the model number 'JZ-801' printed on the PCB. It also indicates the power input terminals (6.0~30.0V, GND) and trigger input (Trigger, GND_TO).

3.1 Güç Girişi

  • DC Girişi: Connect a DC power source between 6V and 30V to the screw terminals labeled 6.0~30.0V (positive) and Yeraltı (olumsuz).
  • Mikro USB Girişi: Alternatively, power the module using a 5V Micro USB power supply connected to the Micro USB port.

3.2 Tetikleyici Girişi

  • The trigger source requires a high voltage level between 3.0V and 24V.
  • Connect the trigger signal to the terminal labeled Tetiklemek and the ground reference to GND_TO.

3.3 Röle Çıkışı

The relay provides three terminals for connecting your load:

  • HAYIR (Normalde Açık): This terminal is open (disconnected) when the relay is de-energized and closed (connected to COM) when energized.
  • COM (Ortak): This is the common terminal for the relay switch.
  • NC (Normalde Kapalı): This terminal is closed (connected to COM) when the relay is de-energized and open (disconnected from COM) when energized.

The relay can control devices within DC 0-30V 5A or AC 0-220V 5A.

4. Kullanım Talimatları

4.1 Main Interface and Display

When the module is off, the display shows "000" (no decimal point). During operation, the display will show a decimal point, indicating active status.

DEVMO JZ801 Relay Board showing LED display and buttons

Figure 4.1: DEVMO JZ801 Relay Board with LED display and control buttons.

This image highlights the 3-digit LED display and the three control buttons (SET, STOP, and an unlabeled button) on the DEVMO JZ801 relay board, which are used for programming and operating the module.

4.2 Parametre Tanımları

  • OP: Turn-On Time (duration the relay is energized).
  • ŞL: Turn-Off Time (duration the relay is de-energized).
  • LOP: Cycle Index (number of cycles). "---" indicates an limitless cycle.

These parameters are independent for each work mode but share the same values across different modes once set.

4.3 Zamanlama Ayarı

To set timing values:

  1. Enter the mode selection screen (see Section 4.4).
  2. After setting the parameter values (OP, CL, LOP), short press the DURMAK button to select the time range for the currently displayed parameter.
  3. Available time ranges:
    • XXX: 1 second to 999 seconds (e.g., 123 for 123 seconds).
    • XX.X: 0.1 seconds to 99.9 seconds (e.g., 12.3 for 12.3 seconds).
    • X.X.X.: 1 minute to 999 minutes (e.g., 1.2.3. for 123 minutes).

4.4 Work Mode Selection

Uzun basın AYARLAMAK key to enter or exit the mode selection screen. In this screen, you can choose different operational modes for the relay.

4.5 Relay Enable/Disable Mode

From the main interface, a short press of the DURMAK button will toggle the relay between ON and OFF states, effectively enabling or disabling its operation.

4.6 Uyku Modu

To activate or deactivate sleep mode:

  1. Uzun basın DURMAK düğmesini iki saniye basılı tutun.
  2. Release the button to switch between Cl (normal mode) and O-d (sleep mode) states.

In sleep mode, if there is no operation for five minutes, the digital display automatically turns off to save power. Press any key to turn the display back on.

5. Bakım

  • Modülü temiz tutun ve tozdan ve nemden uzak tutun.
  • Modülü aşırı sıcaklıklara veya doğrudan güneş ışığına maruz bırakmaktan kaçının.
  • Ensure all connections are secure to prevent intermittent operation.
  • Do not attempt to modify the circuit board, as this may void any warranty and cause damage.

6. Sorun Giderme

  • Modül açılmıyor: Güç kaynağı hacmini doğrulayıntage is within the 6-30V range for DC input, or ensure the Micro USB cable is properly connected to a 5V source. Check for correct polarity on DC input.
  • Relay not triggering: Ensure the trigger signal voltage is between 3.0V and 24V. Check the trigger input connections for proper contact. Verify the selected work mode and timing parameters are correctly configured.
  • Incorrect timing: Double-check the OP, CL, and LOP parameter settings. Ensure the correct time range (seconds, 0.1 seconds, minutes) is selected for each parameter.
  • Ekran kapalı: The module might be in sleep mode. Press any button to reactivate the display. If not in sleep mode, check power supply.
  • Aralıklı operasyon: Check all wiring connections for looseness. Ensure the load current does not exceed the relay's maximum rating (DC 0-30V 5A or AC 0-220V 5A). The built-in opto-isolator helps reduce interference, but ensure your environment is free from excessive electrical noise.

7. Özellikler

Özellik Şartname
Model Numarası JZ801
Boyutlar (U x G x Y) 6.2 cm x 3.8 cm x 1.7 cm (2.44 x 1.50 x 0.67 inç)
İş Hacmitage DC 6-30V (supports Micro USB 5.0V power supply)
Tetikleyici Kaynak yüksek hacimtage level trigger (3.0V-24V)
Çıktı Kapasitesi DC 0-30V 5A or AC 0-220V 5A
Durgun Akım 20mA
Çalışma Akımı 50mA
Hizmet Ömrü 100,000'dan fazla kez
Çalışma Sıcaklığı -40°C ile +85°C arası
Zamanlama Aralığı 0.1 saniye ile 999 dakika arası (ayarlanabilir)
Ağırlık 0.06 Kilogram (yaklaşık 2.08 ons)

8. Garanti ve Destek

Warranty information for the DEVMO DC 5V/12V 1 Channel Relay Board is typically provided at the point of purchase or can be found on the manufacturer's official webLütfen garanti şartları ve koşulları için satın alma belgelerinize bakın.

For technical support, troubleshooting assistance, or further inquiries, please contact your retailer or the DEVMO customer service department through their official channels. Ensure you have your product model number (JZ801) and purchase details available when seeking support.