1. Giriş

The Aqua Control C1114 Automatic Garden Irrigation Programmer is designed to automate your garden's watering system, managing up to 4 independent irrigation zones. This programmer ensures efficient water distribution by allowing precise control over watering schedules, durations, and frequencies. It features an intuitive LCD display and a rotary dial for easy programming.

Aqua Control C1114 Irrigation Programmer front view
Şekil 1: Ön view of the Aqua Control C1114 Irrigation Programmer, showing the LCD display and control buttons.

2. Ürün Özellikleri

  • Çok Bölgeli Kontrol: Manages up to 4 independent irrigation zones.
  • Esnek Programlama: Offers two independent programs (A and B), each with up to 4 start times.
  • Süre Ayarı: Watering duration can be set from 1 minute to 240 minutes (4 hours).
  • Frekans Seçenekleri: Program by specific days of the week, every 'x' days, or odd/even days.
  • Yağmur Geciktirme Fonksiyonu: Temporarily suspends watering for 0, 24, 48, or 72 hours due to rain or other factors.
  • Rain Sensor Compatibility: Connect an external rain sensor to automatically stop watering on rainy days.
  • Master Valve/Pump Start: Includes a connection for a pump or master valve.
  • Kullanıcı Dostu Arayüz: Large LCD display and intuitive rotary dial for easy programming and monitoring.
  • Manuel Sulama Seçeneği: Planlanmamış, anlık sulamaya olanak tanır.

3. Kurulum ve Kurulum

3.1 Güç Kaynağı

The programmer requires a 230 VAC, 50 Hz input transformer (included) which outputs 24 VAC, 0.650A. Additionally, 2 AA alkaline batteries (not included) are required for memory backup and display operation during power outagee.

3.2 Kablo Bağlantıları

Open the battery compartment cover to access the wiring terminals. Connect your solenoid valves, master valve (if applicable), and rain sensor to the appropriate terminals as indicated on the unit.

  • 24VAC: Connect the transformer output.
  • SENSER: Connect an optional rain sensor.
  • C (Common): Connect the common wire from all solenoid valves.
  • M (Master Valve): Connect the master valve, if used.
  • 1, 2, 3, 4: Connect individual zone solenoid valves.
Aqua Control C1114 battery and wiring terminals
Şekil 2: Dahili view showing the battery compartment and wiring terminals for solenoid valves and sensors. Note: 2 AA batteries are required and not included.

3.3 Montaj

Mount the programmer in a sheltered location, away from direct sunlight and extreme weather conditions, using appropriate fasteners through the mounting holes provided.

4. Kullanım Talimatları

The Aqua Control C1114 features a rotary dial and several buttons for easy navigation and programming. Refer to Figure 3 for a visual guide to the control panel.

Aqua Control C1114 control panel diagram with labels
Figure 3: Detailed diagram of the Aqua Control C1114 control panel, indicating the function of each button and dial setting.

4.1 Kontrol Paneli Üstüview

  • LCD Ekran: Geçerli saati, program ayarlarını ve durumunu gösterir.
  • Döner Kadran: Used to select programming modes (SET CLOCK, START TIME, HOW LONG, HOW OFTEN, ON, OFF).
  • MANUEL Düğmesi: Elle sulama işlemini başlatır.
  • PROG A/B Button: Toggles between Program A and Program B.
  • GİRİŞ Düğmesi: Seçimleri ve ayarları onaylar.
  • < / > Buttons: Navigate between parameters or adjust values.
  • + / - Düğmeleri: Increase or decrease numerical values.
  • RAIN DELAY Button: Activates or adjusts the rain delay function.
  • TEMİZLE Düğmesi: Clears current settings or inputs.
  • Yeniden başlatma tuşu: Resets all programming to factory defaults (located under the dial).

4.2 Initial Setup: Setting Current Time and Date

  1. Döner kadranı çevirin SAAT AYARLA.
  2. Kullanın + or - buttons to set the current hour. Press GİRMEK.
  3. Set the current minute. Press GİRMEK.
  4. Set the current day of the week. Press GİRMEK.
  5. kadranı çevirin ON to save settings and return to normal operation.

4.3 Programming Irrigation Schedules (Program A/B)

The programmer allows for two independent programs, A and B. Each program can have up to 4 start times.

  1. Basın PROG A/B button to select either Program A or Program B. The selected program will be displayed on the LCD.
  2. Döner kadranı çevirin BAŞLANGIÇ ZAMANI.
  3. Kullanmak + or - to set the first start time. Press GİRMEK.
  4. Repeat for up to 4 start times. If fewer than 4 are needed, press GİRMEK to skip remaining start times.
  5. Döner kadranı çevirin NE KADARDIR.
  6. Kullanmak + or - to set the watering duration for each zone (from 1 to 240 minutes). Use the < or > buttons to select the zone (1-4) you wish to set. Press GİRMEK after setting each zone's duration.
  7. Döner kadranı çevirin NE SIKLIKTA.
  8. Select the watering frequency:
    • Specific Days: Kullanmak < or > to select days of the week (e.g., MO, TU, WE). Press GİRMEK to select/deselect.
    • Every X Days: Select this option and use + or - to set the interval (e.g., every 2 days).
    • Tek/Çift Günler: Select to water on odd or even calendar days.
    Basmak GİRMEK to confirm your frequency selection.
  9. kadranı çevirin ON Programı etkinleştirmek için.

4.4 Manuel Sulama

To initiate manual watering:

  1. Ensure the rotary dial is set to ON.
  2. Basın KILAVUZ düğme.
  3. Kullanmak + or - to set the desired manual watering duration.
  4. Basmak GİRMEK to start manual watering. The display will show the remaining time.
  5. Manuel sulamayı durdurmak için basın. TEMİZLEMEK or turn the dial to KAPALI ve sonra geri dön ON.

4.5 Yağmur Geciktirme Fonksiyonu

To temporarily suspend watering:

  1. Ensure the rotary dial is set to ON.
  2. Basın YAĞMUR GECİKMESİ düğme.
  3. Kullanmak + or - to select the delay duration (0, 24, 48, or 72 hours).
  4. Basmak GİRMEK to activate the rain delay. The display will show the remaining delay time.
  5. Yağmur nedeniyle oyunun ertelenmesini iptal etmek için tuşuna basın. YAĞMUR GECİKMESİ again and set the duration to 0, then press GİRMEK.

4.6 Turning Off the Programmer

To completely stop all automatic watering, turn the rotary dial to KAPALI. To resume, turn the dial back to ON.

5. Bakım

  • Temizlik: Üniteyi yumuşak, damp Aşındırıcı temizleyiciler kullanmayın veya üniteyi suya batırmayın.
  • Pil Değişimi: Replace the 2 AA alkaline batteries annually or when the low battery indicator appears on the LCD to ensure program memory retention during power outagee.
  • Kışlama: In freezing climates, disconnect the programmer from the power supply and remove it from its outdoor location. Store it indoors in a dry, frost-free environment.

6. Sorun Giderme

SorunOlası NedenÇözüm
Programcı ekranı boş.No power from transformer; dead AA batteries.Check transformer connection and power outlet. Replace AA batteries.
Zones are not watering.Programmer is OFF; Rain Delay active; wiring issue; solenoid valve malfunction.Ensure dial is on ON. Check Rain Delay status. Verify wiring connections. Test solenoid valves.
Sulama yanlış zamanlarda yapılıyor.Incorrect current time/date; incorrect program start times.Re-set current time and day. Review and adjust program start times.
Programmer resets unexpectedly.Power interruption; low AA batteries.Ensure stable power supply. Replace AA batteries.

7. Özellikler

  • Modeli: C1114
  • bölgeler: 4 adede kadar bağımsız bölge
  • Trafo Girişi: 230 VAC, 50Hz
  • Trafo Çıkışı: 24VAC, 0.650A
  • Output per Station: 24 VAC, 15.6 VA
  • Master Valve Output: 24 VAC, 15.6 VA
  • Pil Gereksinimi: 2 x AA Alkaline batteries (not included)
  • Programming Duration: 1 dakikadan 240 dakikaya (4 saat)
  • Aşırı Yük Koruması: Evet
  • Ürün Ağırlığı: Yaklaşık 500 gram