1. Giriş

The Avidsen Orane 400 is an automatic motorization system designed for two-panel swing gates. This system is compatible with various gate materials, including wood, iron, aluminum, or PVC. It is engineered to operate gates up to 2.50 meters per leaf and 200 kg per leaf, with a maximum total width of 5 meters and a total weight of 400 kg. The system allows for an inward opening angle of up to 120° and an outward opening angle of up to 90°.

This manual provides essential information for the safe and efficient installation, operation, and maintenance of your Avidsen Orane 400 gate motorization system.

2. Güvenlik Talimatları

  • Profesyonel Kurulum: Installation should be performed by qualified personnel in compliance with all local electrical and safety regulations.
  • Temiz bölge: Ensure the gate's path is clear of people, pets, and objects before and during operation.
  • Acil durdurma: Acil durdurma prosedürünü öğrenin.
  • Engel Algılama: The system features automatic stop upon obstacle detection. However, always exercise caution.
  • Children and Remote Controls: Keep remote controls out of reach of children to prevent accidental operation.
  • Bakım: Regularly inspect the system for wear, damage, or misalignment. Disconnect power before any maintenance or repair.

3. Paket İçeriği

Kuruluma başlamadan önce tüm bileşenlerin mevcut ve hasarsız olduğundan emin olun.

Avidsen Orane 400 gate motorization system components including two motors, two remote controls, and a flashing lamp.

Image: Avidsen Orane 400 system components, showing two articulated arm motors, two remote controls, and a flashing lamp.

  • 2 x Articulated Arm Motors (24 VDC, with integrated electronics)
  • 1 x Flashing Lamp
  • 2 x Four-Button Remote Controls (433.92 MHz)
  • Fixing Straps and Supports

4. Özellikler

ÜreticiAvidsen
Model Numarası114156
Kapı Tipi2-panel Swing Gates
Compatible Gate MaterialsWood, Iron, Aluminum, PVC
Maksimum Kapı Kanadı UzunluğuYaprak başına 2.50 metre
Maksimum Kapı Kanadı AğırlığıYaprak başına 200 kg
Maksimum Toplam Kapı Genişliği5 metre
Maksimum Toplam Kapı Ağırlığı400 kilo
Inward Opening Angle120°'ye kadar
Outward Opening Angle90°'ye kadar
Uzaktan Kumanda Frekansı433.92 MHz
Uzaktan Kumanda Aralığı100 metreye kadar
Güç Kaynağı24 VDC
Ağırlık (Sistemi)Yaklaşık 15 kg (33.07 lbs)

5. Kurulum ve Kurulum

Proper installation is crucial for the performance and safety of your gate motorization system. It is highly recommended that installation be carried out by a qualified professional.

5.1 Kurulum Öncesi Kontroller

  • Ensure your gate is in good working condition, moves freely, and is properly balanced.
  • Verify that the gate structure can support the weight and forces exerted by the motorization system.
  • Confirm that there is adequate space for the articulated arms to operate without obstruction.

5.2 Motor Montajı

The motors must be securely mounted to the gate pillars or posts. Refer to the diagrams below for critical dimensions and positioning.

Diagram showing motor mounting height 'A' as 510mm.

Image: Motor mounting diagram, indicating a vertical dimension 'A' of 510mm for optimal arm articulation.

Diagram illustrating maximum distance 'D' of 250mm for gate opening.

Image: Gate opening diagram, showing a maximum distance 'D' of 250mm from the pivot point to the motor mounting for proper operation.

Diagram with a table detailing maximum opening angles and corresponding 'D' distances.

Image: Detailed diagram for inward opening, showing central and lateral stops, opening angle, and a table correlating maximum opening angles (90°, 100°, 110°, 120°) with the required 'Distance D' range (-50 to 250mm max, -50 to 160mm max, -50 to 80mm max, -50 to 50mm max respectively).

5.3 Elektrik Bağlantıları

All electrical wiring should be performed by a certified electrician. Ensure the power supply is disconnected before making any connections. Refer to the wiring diagram provided in the full installation manual for specific details on connecting the motors, flashing lamp, and control unit.

5.4 Initial Learning / Programming

After installation, the system requires an initial learning phase to calibrate the gate's travel limits. For this initial learning, it is advised to position the gate leaves at half-open, not fully closed. Starting with the gate fully closed may cause the motor to block due to excessive force during the first maneuver. Follow the specific programming steps outlined in the comprehensive installation guide for your control unit.

6. Kullanım Talimatları

6.1 Uzaktan Kumanda İşlemi

The system includes two 4-button remote controls for convenient operation. The remote controls have an effective range of up to 100 meters, depending on environmental conditions.

  • Pressing a designated button on the remote control will initiate the gate opening or closing sequence.
  • A second press during operation will typically stop the gate.
  • Üçüncü bir basış, kapının yönünü tersine çevirecektir.

6.2 Automatic and Semi-Automatic Closure

The Avidsen Orane 400 offers flexible closure options:

  • Automatic Closure: The gate can be configured to close automatically after a pre-set time delay once it has fully opened.
  • Semi-Automatic Closure: The gate will close only when a command is given via the remote control or other access device.
An automatic gate opening to allow a car to pass through.

Image: A two-panel gate opening automatically, with a car waiting to enter. The flashing lamp on the pillar is active.

An automatic gate closing with an arrow indicating the closing motion.

Image: A two-panel gate closing, with a curved arrow illustrating the closing movement of the gate leaf.

7. Bakım

Düzenli bakım, otomatik kapı sisteminizin uzun ömürlü ve güvenilir çalışmasını sağlar.

  • Aylık Muayene: Check all moving parts, hinges, and mounting points for signs of wear, corrosion, or looseness.
  • Temizlik: Keep the motors and articulated arms clean from dirt, dust, and debris. Avoid using high-pressure washers directly on electrical components.
  • Yağlama: Periodically lubricate the gate hinges and any moving mechanical joints as recommended by the gate manufacturer. Do not lubricate the motor's internal components unless specifically instructed.
  • Obstacle Detection Test: Regularly test the obstacle detection feature by placing a soft, non-damaging object in the gate's path during closure. The gate should stop and reverse.
  • Uzaktan Kumanda Pilleri: Uzaktan kumanda pillerini gerektiğinde değiştirin.

8. Sorun Giderme

If you encounter issues with your Avidsen Orane 400 system, refer to the following common troubleshooting steps:

  • Kapı Uzaktan Kumandaya Yanıt Vermiyor:
    • Uzaktan kumandanın pilini kontrol edin.
    • Ensure you are within the operating range.
    • Verify that the control unit has power.
  • Gate Stops During Operation:
    • Check for any physical obstructions in the gate's path. The obstacle detection system may have activated.
    • Inspect the gate for mechanical issues (e.g., stiff hinges, ground friction).
  • Gate Does Not Close Fully/Opens Partially:
    • The travel limits may need to be re-programmed. Refer to the programming section of the full manual.
    • Ensure there are no obstructions preventing full closure.
  • Yanıp Sönen Lamp Çalışmıyor:
    • l'yi kontrol edinamp's power connection and bulb (if replaceable).

Bu adımlar sorunu çözmezse, müşteri desteğiyle veya yetkili bir teknisyenle iletişime geçin.

9. Garanti ve Destek

9.1 Garanti Bilgileri

Please refer to the warranty card included with your product or visit the official Avidsen website for detailed warranty terms and conditions. The product box indicates a 3-year warranty. Keep your proof of purchase for warranty claims.

9.2 Müşteri Desteği

For technical assistance, spare parts, or further inquiries, please contact Avidsen customer service. Contact details can typically be found on the Avidsen website or in the product packaging. Information regarding the availability of spare parts is not explicitly provided in the product specifications, please inquire directly with Avidsen support.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.